JaLCDOI 10.18926/21085
Title Alternative Automatic measurement of oxygen isotope ratio of water samples
FullText URL pitsr_056_027_034.pdf
Author Chiba, Hitoshi| Sakai, Hitoshi| Yasutake, Masatoshi|
Abstract The automatic sample preparation system for oxygen isotope analysis of natural water samples was constructed. The system is essentially a modification of that originally designed by W. Dansgaard in the University of Copenhagen. Sixty water samples of 5 ml each are automatically equilibrated with CO(2) of 30 ml NTP each within 4.5 hours. The equilibrated CO(2) gases are successively measured for their oxygen isotopic ratios by an automatic mas-sspectrometer, VG903. The time required for the measurement of the 60 CO(2) samples is about 15 hours; thus approximately 20 hours are required to complete the isotopic measurements of 60 water samples. The accuracy of the oxygen isotopic analyses is about 0.1%. The result of oxygen isotopic analyses by the automatic preparation system agrees with that of the conventional method within about +0.1%. The results indicate that the automatic preparation system is applicable for the oxygen isotope analysis of natural water samples.
Publication Title 岡山大学温泉研究所報告
Published Date 1985-03-30
Volume volume56
Start Page 27
End Page 34
ISSN 0369-7142
language Japanese
File Version publisher
NAID 120002310952
JaLCDOI 10.18926/21084
Title Alternative Spa therapy for patients with chronic obstructive lung disease
FullText URL pitsr_056_023_026.pdf
Author Sudo, Michiyasu| Komagoe, Haruki| Tanizaki, Yoshiro| Morinaga, Hiroshi|
Abstract During last three years, 41 patients with chronic obstructive lung disease (39 cases with bronchial asthma and 2 cases with chronic bronchiolitis) received spa therapy at Department of Medicine, Okayama University Medical School, Misasa Medical Branch. 1. Twenty three (56%) out of 41 cases came from Okayama prefecture and 10 cases (24.4%) from Tottori prefecture for spa therapy. In twenty five (61.0%) out of 41 cases, their ages were over 50 years. 2. Thirty nine patients with bronchial asthma were divided into three asthma types classified by clinical symptoms : Ia ; 16 cases (41.0%), Ib; 13 cases (33.3%) and II ; 10 cases (25.7%). Pulmonary function tests for these patients showed that small airways obstruction was most remarkable in type II asthma. 3. The mean serum IgE level of all asthmatic patients (39 cases) was 653.9U/ml. In skin test by allergens, positive immediate skin reaction was shown in 18 cases (46.2%) by Candida and 12 cases (30.8%) by house dust. Specific IgE anti-bodies were found in 9 cases (23.1%) for house dust and 3 cases (7.7%) for Candida.
Publication Title 岡山大学温泉研究所報告
Published Date 1985-03-30
Volume volume56
Start Page 23
End Page 26
ISSN 0369-7142
language Japanese
File Version publisher
NAID 120002311025
JaLCDOI 10.18926/21083
Title Alternative 好塩基球からのヒスタミン遊離に関する研究. 5.臨床的評価
FullText URL pitsr_056_017_021.pdf
Author Tanizaki, Yoshiro| Komagoe, Haruki| Sudo, Michiyasu| Morinaga, Hiroshi|
Abstract 過去3年間にわたり,気管支喘息患者末梢血好塩基球からのヒスタミン遊離について,ヒスタミン自動分析装置を用いて全血法により検討を加えてきた. 1. 抗ヒトIgE によるヒスタミン遊離は,症例間で著しい差がみられた. この際血清IgE値が高値を示す症例では全般的に高度なヒスタシソ遊離がみられたが,血清IgE値が正常かまたはむしろ低値を示す症例のヒスタミン遊離は,かなり高度なものから全くみられないものまでさまざまであった. 2.ハウスダストやカンジダなどの抗原物質によるヒスタミン遊離は,特異的IgE抗体依存性であり,抗体価が上昇するにつれヒスタミン遊離は高度となる傾向がみられた. しかし,ハウスダストとカンジダによるヒスタミン遊離には若干の差がみられた. すなわち,ハウスダストと抗ヒトIgE によるヒスタミン遊離の間には密接な関連がみられたが,カンジダと抗ヒトIgEの間には全く関連がみられなかった. またカンジダによるヒスタミン遊離においては,IgE系反応以外の反応が関与する可能性が一部示唆された.
Publication Title 岡山大学温泉研究所報告
Published Date 1985-03-30
Volume volume56
Start Page 17
End Page 21
ISSN 0369-7142
language English
File Version publisher
NAID 120002310985
JaLCDOI 10.18926/21082
Title Alternative The effect on tissue perfusion by brine spring (solquellen)
FullText URL pitsr_056_013_016.pdf
Author Komoto, Yoshiaki| Kohmoto, Tomoji| Sunakawa, Mitsuru| Komoto, Junko|
Abstract Changes in partial pressures of each tissue gas and tissue perfusion were evaluated in the 2.5% artificial salt baths by means of medical mass spectrometry using 9 rabbits. The level of subcutaueous PO(2) lowered by 18% and PCO(2) elevated by 7 % compared with the plain water bath. The tissue perfusion volume was found increased by few %. It is assumed that we owe the warm feeling after taking concentrated salt baths to the improved tissue perfusion.
Publication Title 岡山大学温泉研究所報告
Published Date 1985-03-30
Volume volume56
Start Page 13
End Page 16
ISSN 0369-7142
language Japanese
File Version publisher
NAID 120002311012
JaLCDOI 10.18926/21081
Title Alternative An application of the artificial CO(2) bath for enuresis
FullText URL pitsr_056_009_011.pdf
Author Komoto, Junko| Komoto, Yoshiaki|
Abstract The artificial CO(2) bath was prescribed for two enuretic boys with bladder-sensitive or parasympaticotonic type. A tablet of 50 g, made from sodium bicarbonate and succinic acid, was put in a bath-tub of 150-200 L at 40℃. Each patient was recommended to take a bath with his mother longer than ten minutes, and to mark the presence or the absence of enuresis every day. Outcome results of case 1 on CO(2) bath is shown in tabel 1 and results of case 2 on CO(2) bath is shown in table 3. Both two cases became free from enuresis 7-10 days after the initiation of the artificial CO(2) bathing. Etiological mechanisms of enuresis seem to be multi-factorious, with underlining networks of central- and autonomous nerve systems for the control of sleep and bladder. It is suspected that some improvement of peripheral circulation by CO(2)-bathing leading to keep the body warm may be one of the contributing factors which prolong the intervals of urination, resulting in autonomous normalization, at least, for the cases of bladder-sensitive enuresis, Further case studies are needed to support this assumption.
Publication Title 岡山大学温泉研究所報告
Published Date 1985-03-30
Volume volume56
Start Page 9
End Page 11
ISSN 0369-7142
language Japanese
File Version publisher
NAID 120002310958
JaLCDOI 10.18926/21080
Title Alternative A case of psychogenic fever
FullText URL 056_005_008.pdf
Author Komoto, Junko| Yasumoto, Ikuko|
Abstract An 18 years old girl, who developed high fever following sore throat without demonstrable organic findings, was diagnosed as having psychogenic fever. Symptom was apparently related to her psychological conflicts in an unconscious pursuit of both the primary gain (avoidance to take examination for college) and the secondary gain (satisfaction for dependancy-need). Initiation, exacerbation and termination of fever were not under voluntary control but produced by self-induced hypnosis. Details of her hypnotic process together with her insight into the condition after psychotherapy were described as clinical data.
Publication Title 岡山大学温泉研究所報告
Published Date 1985-03-30
Volume volume56
Start Page 5
End Page 8
ISSN 0369-7142
language Japanese
File Version publisher
JaLCDOI 10.18926/21079
Title Alternative Radioactivity and chromosome aberrations of residents of Misasa Spa
FullText URL pitsr_056_001_004.pdf
Author Morinaga, Hiroshi| Mifune, Masaaki| Furuno, Katsuaki|
Abstract Misasa Spa is one of the most highly radioactive hot springs in Japan, the waters of which contain mainly (222)Rn (437±132 Bq/liter). Radon contents of indoor air of private houses and health resort hotels (built of wood) at Misasa Spa range from 18.5 to 55.5 mBq/liter and 22.2 to 129.5 mBq/liter, respectively. Radon contents in the air of facilities using spring waters at Misasa Branch Hospital of Okayama University were measured to be ; bathroom 807±78 mBq/liter; Hubbardtank bathroom 5306±2568 mBq/liter ; the drinking hall 1491±178 mBq/liter. The environmental and dose rate inside private houses has been measured to be 14.0±1.8 μR/h. Chromosome aberrations (dicentrics) in the peripheral blood lymphocytes of residents of Misasa Spa were investigated in 14 persons; the mean value of aberration frequencies were 0.21%.
Publication Title 岡山大学温泉研究所報告
Published Date 1985-03-30
Volume volume56
Start Page 1
End Page 4
ISSN 0369-7142
language Japanese
File Version publisher
NAID 120002311024
Author Korenaga, Takashi| Ikatsu, Hisayoshi| Takahashi, Teruo|
Published Date 1982-11-01
Publication Title 岡山大学環境管理センター報
Volume volume4
Content Type Departmental Bulletin Paper
Author Ikatsu, Hisayoshi| Kaseno, Satoru| Korenaga, Takashi| Takahashi, Teruo|
Published Date 1984-11-01
Publication Title 岡山大学環境管理センター報
Volume volume6
Content Type Departmental Bulletin Paper
Author Moriwake, Toshio|
Published Date 1986-11-01
Publication Title 岡山大学環境管理センター報
Volume volume8
Content Type Departmental Bulletin Paper
Author Takahashi, Teruo|
Published Date 1986-11-01
Publication Title 岡山大学環境管理センター報
Volume volume8
Content Type Departmental Bulletin Paper
Author Kaseno, Satoru| Takahashi, Teruo| Korenaga, Takashi|
Published Date 1987-11-01
Publication Title 岡山大学環境管理センター報
Volume volume9
Content Type Departmental Bulletin Paper
Author Korenaga, Takashi|
Published Date 1987-11-01
Publication Title 岡山大学環境管理センター報
Volume volume9
Content Type Departmental Bulletin Paper
Author Shinoda, Sumio|
Published Date 1987-11-01
Publication Title 岡山大学環境管理センター報
Volume volume9
Content Type Departmental Bulletin Paper
Author Kaseno, Satoru| Takahashi, Teruo|
Published Date 1988-12-01
Publication Title 岡山大学環境管理センター報
Volume volume10
Content Type Departmental Bulletin Paper
Author Korenaga, Takashi| Kaseno, Satoru|
Published Date 1988-12-01
Publication Title 岡山大学環境管理センター報
Volume volume10
Content Type Departmental Bulletin Paper
Author Takahashi, Teruo|
Published Date 1988-12-01
Publication Title 岡山大学環境管理センター報
Volume volume10
Content Type Departmental Bulletin Paper
Author Takeuchi, Fumiaki| Korenaga, Takashi| Shinoda, Sumio| Takahashi, Teruo|
Published Date 1989-12-15
Publication Title 岡山大学環境管理センター報
Volume volume11
Content Type Departmental Bulletin Paper
Author 城 義信| Kaseno, Satoru| Takahashi, Teruo| Shinoda, Sumio|
Published Date 1990
Publication Title 環境制御
Volume volume12
Content Type Departmental Bulletin Paper
Author Korenaga, Takashi| Kaseno, Satoru|
Published Date 1990
Publication Title 環境制御
Volume volume12
Content Type Departmental Bulletin Paper