ID | 33009 |
フルテキストURL | |
著者 |
Sabarudin, Akhmad
Department of Chemistry, Faculty of Science, Okayama University
Noguchi, Osamu
Department of Chemistry, Faculty of Science, Okayama University
大島 光子
Department of Chemistry, Faculty of Science, Okayama University
Higuchi, Keiro
FIA Instruments Division, Ogawa and Co.
本水 昌二
Department of Chemistry, Faculty of Science, Okayama University
|
抄録 | Chitosan resin functionalized with 3,4-dihydroxy benzoic acid (CCTS-DHBA resin) was used as a packing material for flow injection (FI) on-line mini-column preconcentration in combination with inductively coupled plasma-atomic emission spectrometry (ICP-AES) for the determination of trace elements such as silver, bismuth, copper, gallium, indium, molybdenum, nickel, uranium, and vanadium in environmental waters. A 5-mL aliquot of sample (pH 5.5) was introduced to the minicolumn for the adsorption/preconcentration of the metal ions, and the collected analytes on the mini-column were eluted with 2 M HNO3, and the eluates was subsequently transported via direct injection to the nebulizer of ICP-AES for quantification. The parameters affecting on the sensitivity, such as sample pH, sample flow rate, eluent concentration, and eluent flow rate, were carefully examined. Alkali and alkaline earth metal ions commonly existing in river water and seawater did not affect the analysis of metals. Under the optimum conditions, the method allowed the determination of metal ions with detection limits of 0.08 ng mL(-1) (Ag), 0.9 ng mL(-1) (Bi), 0.07 ng mL(-1) (Cu), 0.9 ng mL(-1) (Ga), 0.9 ng mL(-1) (In), 0.08 ng mL(-1) (Mo), 0.09 ng mL(-1) (Ni), 0.9 ng mL(-1) (U), and 0.08 ng mL(-1) (V). By using 5 mL of sample solution, the enrichment factor and collection efficiency were 8-12 fold and 96-102%, respectively, whereas the sample throughput was 7 samples/hour. The method was validated by determining metal ions in certified reference material of river water (SLRS-4) and nearshore seawater (CASS-4), and its applicability was further demonstrated to river water and seawater samples. |
キーワード | flow injection
chitosan resin
on-line preconcentration
3
4-dihydroxy benzoic acid
ICP-AES
|
備考 | Published with permission from the copyright holder.
This is published in Microchimica Acta, 2007 Vol.159 Issue.3-4 pp.341-348 Publisher URL: http://dx.doi.org/10.1007/s00604-007-0734-y Direct access to Thomson Web of Science record (C)2007 by Springer. |
発行日 | 2007-04-26
|
出版物タイトル |
Microchimica Acta
|
巻 | 159巻
|
号 | 3-4号
|
開始ページ | 341
|
終了ページ | 348
|
資料タイプ |
学術雑誌論文
|
言語 |
英語
|
査読 |
有り
|
DOI | |
Web of Science KeyUT | |
Submission Path | analytical_chemistry/35
|