このエントリーをはてなブックマークに追加


ID 69749
フルテキストURL
著者
Kitamura, Wataru Department of Hematology and Oncology, Okayama University Hospital
Fujii, Keiko Department of Hematology and Oncology, Okayama University Hospital Kaken ID researchmap
Abe, Masaya Department of Hematology and Oncology, Okayama University Hospital
Ikeuchi, Kazuhiro Department of Hematology and Oncology, Okayama University Hospital
Washio, Kana Department of Pediatrics, Okayama University Hospital
Otsuka, Fumio Division of Clinical Laboratory, Okayama University Hospital ORCID Kaken ID publons researchmap
Maeda, Yoshinobu Department of Hematology and Oncology, Okayama University Hospital Kaken ID researchmap
Fujii, Nobuharu Department of Hematology and Oncology, Okayama University Hospital Kaken ID publons researchmap
抄録
For the manufacturing of tisagenlecleucel (tisa-cel) requires the non-mobilized mononuclear cell collection (MNC). CD3+ cell collection is performed using the same protocol as autologous peripheral blood stem cell harvest (auto-PBSCH), but this procedure necessitates the same target CD3+ cell yields regardless of age or body weight, which may take several days especially in pediatric and small female patients with low white blood cell counts. We previously demonstrated a novel method using highly concentration sodium citrate (HSC), which reduced the need for an anticoagulant (AC) solution and shortened the procedure time in auto-PBSCH. This novel method was expected to offer advantages for smaller patients, prompting us to investigate its application in leukocytapheresis for the manufacturing of tisa-cel. We retrospectively analyzed consecutive leukocytapheresis data obtained using Spectra Optia continuous MNC mode between November 2022 and June 2024 at our institution (n = 9). In six of nine patients, pre-leukocytapheresis CD3+ cell counts were less than 500 /μL, but all could obtain the target CD3+ cell yields in one day upon processing blood volume adjustment. When we compared patients who had received CD3+ cell collection using normal-concentration sodium citrate (NSC) as our previously reported using propensity score-matched pair analysis, the total AC solution volume was significantly lower (1168 vs. 316 mL, p < 0.001) and procedure time was significantly shorter (254 vs. 228 min, p = 0.04) in the HSC group compared to the NSC group. In conclusion, this procedure was also useful for non-mobilized MNC. Our findings warrant validation in a larger patient cohort.
キーワード
Chimeric antigen receptor T cell therapy
Anticoagulant
Acid citrate dextrose solution A
Highly concentrated sodium citrate
発行日
2025-12
出版物タイトル
Transfusion and Apheresis Science
64巻
6号
出版者
Elsevier BV
開始ページ
104265
ISSN
1473-0502
NCID
AA11555942
資料タイプ
学術雑誌論文
言語
英語
OAI-PMH Set
岡山大学
著作権者
© 2025 The Authors.
論文のバージョン
publisher
PubMed ID
DOI
Web of Science KeyUT
関連URL
isVersionOf https://doi.org/10.1016/j.transci.2025.104265
ライセンス
http://creativecommons.org/licenses/by-nc/4.0/