Matoba, Ryo Department of Ophthalmology, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Sciences
Morizane, Yuki Department of Ophthalmology, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Sciences
Kimura, Shuhei Department of Ophthalmology, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Sciences
Toshima, Shinji Department of Ophthalmology, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Sciences
Shiraga, Fumio Department of Ophthalmology, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Sciences
抄録
Internal limiting membrane (ILM) peeling is an important maneuver in vitrectomy for macular holes (MHs). A nitinol loop is a surgical instrument designed to create an edge on the ILM and peel the ILM safely and consistently. The effect of using a nitinol loop for ILM peeling on the retina is not clear. We report here on a case of an idiopathic full-thickness MH in an adult woman, in whom retinal damage was revealed after her ILM was peeled using a nitinol loop.