抄録

A highly sensitive fluorescence quenching method for the determination of silicate based on the formation of an ion associate between molybdosilicate and Rhodamine B (RB) in nitric acid medium was developed. A flow injection system coupled with a fluorescence detector was used for the measurement of fluorescence intensity at 560 and 580 nm as excitation and emission wavelengths, respectively. The calibration graph for Si showed a linear range of 0.1-5 ng cm(-3) with correlation coefficient of 0.9999, and the detection limit of 0.06 ng cm(-3). The proposed method was successfully applied to the determination of silicate in ultrapurified water with satisfactory results.

キーワード
ultrapurified water
ion associate
molybdosilicate
rhodamine B
flow injection
fluorescence quenching
備考
Published with permission from the copyright holder.
This is published in Talanta, 2003 Vol.60 Issue.6 pp.1277-1285
Publisher URL: http://dx.doi.org/10.1016/S0039-9140(03)00234-0
Direct access to Thomson Web of Science record
(C)2003 by Elsevier B.V.
発行日
2003-08-29
出版物タイトル
Talanta
60巻
6号
開始ページ
1277
終了ページ
1285
資料タイプ
学術雑誌論文
言語
英語
査読
有り
DOI
Web of Science KeyUT
Submission Path
analytical_chemistry/29