ID | 42842 |
フルテキストURL | |
タイトル(別表記) | Studies on the Hearing Test with Speech Sound Part. 3. Hearing Test with Speech Sound of Japanese
|
著者 |
宮本 正明
岡山大学医学部耳鼻咽喉科教室
|
抄録 | In this test, senseless monosyllabic sounds of Japanese speech are used. Generally, 100 sounds are used in one test. As to the test-distance, the point where the difference between normal hearing and slightly impaired hearing begins to be noticed, is determined as standard distance at each test room by each tester. In proportion as the noise of the test room increases, the standard distance is getting shorter. The experiments show that the result of the test is reliable when the standard distance of test room is longer than 1/3 of the standard distance in the sound proof room. The degree of hearing difficulty is expressed in the name of "mis-hearing rate, " which indicates the proportion of the sum of hearing loss and mis-hearing to the tested words' number in percentage. From the results obtained by the above described method, I could classify the patients into 5 categories according to the percentage of hearing loss:
normal hearing, less than 5%; very slight difficulty, 5-10%; slight difficulty, 20-30%; moderate difficulty, more than 50%; severe difficulty, 100%.
|
発行日 | 1955-04-30
|
出版物タイトル |
岡山医学会雑誌
|
出版物タイトル(別表記) | Journal of Okayama Medical Association
|
巻 | 67巻
|
号 | 3-4号
|
出版者 | 岡山医学会
|
出版者(別表記) | Okayama Medical Association
|
開始ページ | 855
|
終了ページ | 867
|
ISSN | 0030-1558
|
NCID | AN00032489
|
資料タイプ |
学術雑誌論文
|
オフィシャル URL | https://www.jstage.jst.go.jp/article/joma1947/67/3-4/67_3-4_855/_article/-char/ja/
|
関連URL | http://www.okayama-u.ac.jp/user/oma/
|
言語 |
日本語
|
著作権者 | Copyright© 岡山医学会
|
論文のバージョン | publisher
|
査読 |
有り
|
Eprints Journal Name | joma
|