このエントリーをはてなブックマークに追加


ID 71430
フルテキストURL
fulltext.pdf 4.04 MB
著者
Takaya, Arisa Department of Chemistry, Okayama University
Kaneta, Takashi Department of Chemistry, Okayama University ORCID Kaken ID publons researchmap
抄録
Extracellular vesicles (EVs), including exosomes, have attracted considerable attention as promising biomarkers for the early diagnosis and prognosis of cancer. In this study we evaluated the efficiency of a click chemistry-based EV labeling method using a two-color laser-induced fluorometry (LIF) system. During cell culture, cellular membranes were metabolically functionalized with azide groups, and the released EVs were subsequently labeled with Cy5 via click chemistry. The collected EVs were then stained with a phycoerythrin-conjugated anti-CD63 antibody (PE-anti-CD63) to achieve dual labeling. A two-color LIF system equipped with 488- and 635-nm lasers was used to distinguish Cy5-labeled, CD63-positive EVs from Cy5-unlabeled, CD63-positive EVs. Because PE and Cy5 are selectively excited at 488 and 635 nm, respectively, Cy5-labeled, CD63-positive EVs generated coincident dual-color fluorescence, whereas Cy5-unlabeled, CD63-positive EVs emitted fluorescence only upon 488-nm excitation. Using this platform, we investigated the effect that serum concentration in the culture medium exerts on click-chemistry labeling efficiency for CD63-positive EVs. The highest labeling efficiency for both HeLa and A549 cells was obtained in medium supplemented with 10% fetal bovine serum. These findings demonstrate the utility of the proposed two-color LIF system for quantitatively evaluating the click-chemistry labeling efficiency of CD63-positive EVs under different cell-culture conditions.
キーワード
Extracellular vesicle
Exosome
Laser-induced fluorescence
Click chemistry
Fluorescent labeling
発行日
2026-10-28
出版物タイトル
Analytical Sciences
出版者
Springer Science and Business Media LLC
ISSN
0910-6340
NCID
AA10500785
資料タイプ
学術雑誌論文
言語
英語
OAI-PMH Set
岡山大学
著作権者
© The Author(s) 2026
論文のバージョン
publisher
PubMed ID
DOI
Web of Science KeyUT
関連URL
isVersionOf https://doi.org/10.1007/s44211-026-00979-x
ライセンス
http://creativecommons.org/licenses/by/4.0/
Citation
Takaya, A., Kaneta, T. Two-color, laser-induced fluorometry for evaluating the efficiency of click chemistry-based labeling of extracellular vesicles. ANAL. SCI. (2026). https://doi.org/10.1007/s44211-026-00979-x
助成情報
25K01800: 全反射蛍光法と能動的吸着制御を用いた単一エクソソームのタンパク質計数 ( 独立行政法人日本学術振興会 / Japan Society for the Promotion of Science )
( 国立大学法人岡山大学 / Okayama University )