| ID | 71430 |
| フルテキストURL | |
| 著者 |
Takaya, Arisa
Department of Chemistry, Okayama University
|
| 抄録 | Extracellular vesicles (EVs), including exosomes, have attracted considerable attention as promising biomarkers for the early diagnosis and prognosis of cancer. In this study we evaluated the efficiency of a click chemistry-based EV labeling method using a two-color laser-induced fluorometry (LIF) system. During cell culture, cellular membranes were metabolically functionalized with azide groups, and the released EVs were subsequently labeled with Cy5 via click chemistry. The collected EVs were then stained with a phycoerythrin-conjugated anti-CD63 antibody (PE-anti-CD63) to achieve dual labeling. A two-color LIF system equipped with 488- and 635-nm lasers was used to distinguish Cy5-labeled, CD63-positive EVs from Cy5-unlabeled, CD63-positive EVs. Because PE and Cy5 are selectively excited at 488 and 635 nm, respectively, Cy5-labeled, CD63-positive EVs generated coincident dual-color fluorescence, whereas Cy5-unlabeled, CD63-positive EVs emitted fluorescence only upon 488-nm excitation. Using this platform, we investigated the effect that serum concentration in the culture medium exerts on click-chemistry labeling efficiency for CD63-positive EVs. The highest labeling efficiency for both HeLa and A549 cells was obtained in medium supplemented with 10% fetal bovine serum. These findings demonstrate the utility of the proposed two-color LIF system for quantitatively evaluating the click-chemistry labeling efficiency of CD63-positive EVs under different cell-culture conditions.
|
| キーワード | Extracellular vesicle
Exosome
Laser-induced fluorescence
Click chemistry
Fluorescent labeling
|
| 発行日 | 2026-10-28
|
| 出版物タイトル |
Analytical Sciences
|
| 出版者 | Springer Science and Business Media LLC
|
| ISSN | 0910-6340
|
| NCID | AA10500785
|
| 資料タイプ |
学術雑誌論文
|
| 言語 |
英語
|
| OAI-PMH Set |
岡山大学
|
| 著作権者 | © The Author(s) 2026
|
| 論文のバージョン | publisher
|
| PubMed ID | |
| DOI | |
| Web of Science KeyUT | |
| 関連URL | isVersionOf https://doi.org/10.1007/s44211-026-00979-x
|
| ライセンス | http://creativecommons.org/licenses/by/4.0/
|
| Citation | Takaya, A., Kaneta, T. Two-color, laser-induced fluorometry for evaluating the efficiency of click chemistry-based labeling of extracellular vesicles. ANAL. SCI. (2026). https://doi.org/10.1007/s44211-026-00979-x
|
| 助成情報 |
25K01800:
全反射蛍光法と能動的吸着制御を用いた単一エクソソームのタンパク質計数
( 独立行政法人日本学術振興会 / Japan Society for the Promotion of Science )
( 国立大学法人岡山大学 / Okayama University )
|