| ID | 34059 |
| フルテキストURL | |
| 著者 |
Ogasawara, Satoshi
Okayama University
Ayano, Hideki
Okayama University
Akagi, Hirofumi
Okayama University
|
| 抄録 | This paper presents theoretical and experimental relationships in between radiated electromagnetic noises and common-mode and normal-mode currents, paying attention to an induction motor drive system fed by a voltage-source PWM inverter. A method of reducing both the currents is proposed, based on an equivalent model taking parasitic stray capacitors inside an induction motor into account. Electromagnetic interference (EMI) radiated by a 3.7 kW induction motor drive system is actually measured, complying with the VDE 0871 Class A [3m]. Experimental results verify that the combination of the already proposed common-mode transformer and the normal-mode filters being proposed in this paper is a practically viable and effective way to reduce the EMI resulting from both the common-mode and normal-mode currents |
| キーワード | AC motor drives
PWM invertors
capacitance
electromagnetic interference
filters
transformers
|
| 備考 | Digital Object Identifier: 10.1109/IAS.1996.560213
Published with permission from the copyright holder. This is the institute's copy, as published in Industry Applications Conference, 1996. Thirty-First IAS Annual Meeting, IAS '96., Conference Record of the 1996 IEEE, 6-10 Oct. 1996, Volume 2, Pages 1072-1079. Publisher URL:http://dx.doi.org/10.1109/IAS.1996.560213 Copyright © 1996 IEEE. All rights reserved. |
| 発行日 | 1996-10
|
| 出版物タイトル |
Industry Applications Conference
|
| 巻 | 2巻
|
| 開始ページ | 1072
|
| 終了ページ | 1079
|
| 資料タイプ |
学術雑誌論文
|
| 言語 |
英語
|
| 査読 |
有り
|
| DOI | |
| Submission Path | electrical_engineering/26
|