
検索結果 1083 件
| JaLCDOI | 10.18926/21149 |
|---|---|
| タイトル(別表記) | Studies on sinter deposits in Misasa radioactive hot springs (2nd report) |
| フルテキストURL | pitsr_051_035_042.pdf |
| 著者 | 古野 勝志| 御舩 政明| 森永 寛| 福島 覚| 和田 洋明| |
| 抄録 | Qualitative and quantitative analysis of sinter deposits in a distributing pipe used for seventeen years (Sample No.1) and adhere to bathtub wall for eleven years (Sample No.2 and Sample No.3) in Misasa radioactive hot springs were investigated. The results were as follows ; (1) The color of deposits of Sample No.1 and Sample No.2 was black and the color of deposits of Sample No.3 was white. The metal elements in these deposits were qualitative analysed by spectraspan plasma emission spectrophotometry (SPES) and by fluorescent X-ray spectrometry. Following elements were detected, in Sample No.1 : Na, Mg, Al, K, Ca, Mn, Fe, Cu, As, Sr, Ba, Mo, and Pb, in Sample No.2 : Na, Mg, Al, Si, K, Ca, Ti, Mn, Fe, Cu, Zn, As, Sr, Ba, Pb and Cl and in Sample No.3 : Na, Mg, Al, Si, K, Ca, Mn, Fe, Cu, Zn, As, Rb, Sr, Mo, Ba, S, and Cl, (2) The metal elements in these deposits were quantitative analysed by SPES, atomic absorption spectrophotometry and emission spectrophometry. Following elements were determined, in Sample No.1 ; Mn : 411.6, Fe : 65.7, Ba : 20.0, Ca : 11.9, Na : 5.7, Cu : 4.5, K : 4.2, Sr : 2.9, Zn : 2.6, Mg : 1.4, in Sample No.2 ; Mn : 248.2, Fe : 28.5, Ba : 15.6, Ca : 25.0, Mg : 10.5, Na : 9.3, Cu : 5.4, K : 4.9, Sr: 7.4, Zn : 3.3, and in Sample No.3 ; Ca : 275.2, Sr : 32.4, Mg: 12.4, Na: 18.7, K: 5.0, Mn: 1.7 and Fe: 0.6mg per gram. The main components of these deposits were manganese compounds (Sample No.1 and Sample No.2) and calcium compounds (Sample No.3). Qualitative and quantitative analysis of barium in sinter deposits of Misasa spa was done by authers for the first time. (3) Radioactivity in these deposits were observed by autoradiography. Among the radioactive elements, concentration of radium were 3.41×10(-8) Ci/g (Sample No.1), 4.70×10(-9) Ci/g (Sample No.2) anp 2.36×10(-11) Ci/g (Sample No.3), respectively. |
| 出版物タイトル | 岡山大学温泉研究所報告 |
| 発行日 | 1981-03-25 |
| 巻 | 51巻 |
| 開始ページ | 35 |
| 終了ページ | 42 |
| ISSN | 0369-7142 |
| 言語 | 日本語 |
| 論文のバージョン | publisher |
| NAID | 120002311013 |
| JaLCDOI | 10.18926/21139 |
|---|---|
| タイトル(別表記) | Isotopic Analysis of Rb and Sr Using a Full Automatic Thermal Ionization Mass Spectrometer |
| フルテキストURL | pitsr_052_051_070.pdf |
| 著者 | 加々美 寛雄| 岡野 修| 須藤 宏| 本間 弘次| |
| 抄録 | Analytical method for strontium isotope ratios and rubidium and strontium concentrations has been established using a full automatic thermal ionization mass spectrometer. The machine is a modified model "MAT 260" of Varian MAT LTD. Each of simultaneously loaded thirteen samples is successively analysed full automatically following to a specific controling program which has been selected as being most suitable for each sample. However, the most characteristic feature of this machine compared to other types is computer controled peak jumping and peak centering before measurment of the signal of each peak. By this the accuracy of isotopic measurement has been surprisingly improved. Analytical procedures are described in detail which include decomposition of samples, separation of Rb and Sr, loading samples on filament and mass spectrometry. Accuracy and reproducibility of isotope analyses are excellent : 43 separate analyses of standard sample NBS 987 over one year gave a mean (87)Sr/(86)Sr ratio of 0.710238 (normalized to the (88)Sr/(86)Sr ratio of 8.375209) with a value of 20δ of 0.000008. The ratio obtained is slightly higher than the value of 0.71014 given by NBS, but it is almost identical to the mean of recently reported twenty analyses. Our determinations for Rb and Sr concentrations of standard samples are as follows : JG-1, Rb 184.4 ppm, Sr 185.5 ppm; JB-l, Rb 41.5Ppm, Sr 448.4 ppm , each of which is near the mean of reported values for corresponding element of the sample (ANDO et al., 1974). Concentrations of Rb and Sr in pure water and regents used in chemical treatement of samples were also measured; a possible error due to the contamination is negligible for most geochemical samples. |
| 出版物タイトル | 岡山大学温泉研究所報告 |
| 発行日 | 1982-03-25 |
| 巻 | 52巻 |
| 開始ページ | 51 |
| 終了ページ | 70 |
| ISSN | 0369-7142 |
| 言語 | 日本語 |
| 論文のバージョン | publisher |
| NAID | 120002310968 |
| JaLCDOI | 10.18926/21126 |
|---|---|
| タイトル(別表記) | Comparison of sulfur isotope ratio measurements by various techniques, and the δ(34)S values of some sulur standards |
| フルテキストURL | pitsr_053_077_084.pdf |
| 著者 | 柳沢 文孝| 三好 正| 上田 晃| 酒井 均| |
| 抄録 | Three techniques (combustion of Ag(2)S by Cu(2)O, thermal decomposition of BaSO(4) and KIBA reagent method under vacuum) for sulfur isotope ratio measurements of geological samples are described in detail. The δ(34)S values of three working standards (MSS-2, MSS-3 and MSS-4) obtained by these techniques for the last 13 years were compared (Table 1 and Fig. 3): the most acceptable values of the three standards are +21.5, +3.5 and +4.5‰, respectively. |
| 出版物タイトル | 岡山大学温泉研究所報告 |
| 発行日 | 1983-03-25 |
| 巻 | 53巻 |
| 開始ページ | 77 |
| 終了ページ | 84 |
| ISSN | 0369-7142 |
| 言語 | 日本語 |
| 論文のバージョン | publisher |
| NAID | 120002310986 |
| JaLCDOI | 10.18926/21109 |
|---|---|
| タイトル(別表記) | Properties of materials under hydrothermal conditions. I. Permeation of hydrogen through gold membrane |
| フルテキストURL | pitsr_054_055_060.pdf |
| 著者 | 木島 宣明| |
| 抄録 | Permeation rate of hydrogen through a gold cell made as a reaction vessel for a Dickson-type hydrothermal apparatus was measured at 50°intervals from 300°to 450℃ under a hydrothermal condition. The gold cell chosen for the measurement had a shape and size illustrated in Fig. 1 when it was fully expanded, and was a typical one in the meaning that it had been used several times for hydrothermal experiments (its total history may be equivalent to one month at 490℃) and that it had a body enlarged by about 8% in diameter from the original size as a result of pinhole check made by applying a gas pressure to the inside. The cell was filled with an appropriate amount of pure water, placed in a pressure vessel made of Ni-base alloy, pressurized by injecting water to the outside of the cell and kept under predetermined temperatures and pressure (=1 kbar). Meanwhile, small fractions of the waters inside and outside the cell were sampled at times and analyzed for H(2) gas-chromatographically as described in ref. (5). H(2) concentrations in the samples (CH(2)) were converted to H(2) fugacity values by using the conversion factors (Y) given in ref. (6). At each temperature, the permeation rate (k) of H(2) through the cell is evaluated by correlating the measured fH(2) values with time (t) according to eq. (2), where fo is the fH(2) in the outer water and is a constant, and fi and m are the fH(2) in and the mass of the inner water, respectively. The relevant data and results are shown in Table 1. The present data for the permeation rate φ, expressed in c㎥ H(2) at STP per 1c㎡ surface area, 1 mm wall thickness, 1 (bar)(1/2) of (fH(2))(1/2) difference and 1 hour, are plotted in Fig. 2 in relation to 1/T (K) and compared with one available data, which is a combination of reported solubility and diffusion coefficient data for hydrogen into gold at higher temperatures. The present data can be fitted into eq. (3). The present result may be of importance for hydrothermal experimental studies of geochemical redox reactions and of hydrogen isotope exchange reactions, and the technique used may also be important as a new, simple method of measuring hydrogen permeability through noble metals. |
| 出版物タイトル | 岡山大学温泉研究所報告 |
| 発行日 | 1984-03-25 |
| 巻 | 54巻 |
| 開始ページ | 55 |
| 終了ページ | 60 |
| ISSN | 0369-7142 |
| 言語 | 日本語 |
| 論文のバージョン | publisher |
| NAID | 120002310991 |
| JaLCDOI | 10.18926/21096 |
|---|---|
| タイトル(別表記) | Properties of materials under hydrothermal conditions: II. Permeability to aqueous NaCl and decomposition of poly(tetrafluoroethylene) (teflon) |
| フルテキストURL | pitsr_055_011_014.pdf |
| 著者 | 木島 宣明| |
| 抄録 | A piece of poly(tetrafluoroethylene) (PTFE) enclosing NaCI powder and having the dimensions shown in the inset in Fig. 1 was placed along with water in a deformable gold cell in a Dickson-type hydrothermal apparatus, and heated stepwise up to 410℃ under a constant pressure of 1 kbar. During the heating, small fractions of the solution in the cell were sampled and analyzed gas chromatographically for H(2), O(2), CH(4) and CO(4), and ion chromatographically for F(-) and Cl(-). No evolution of gases (H(2), CH(4), CO(2)) due to decomposition of PTFE, other than that due to decomposition of organic impurities, was observed over the temperature range of the experiment. The ion chromatographic analysis showed (Fig. 1) that : (1) Cl(-)leaching from the PTFE test piece continued even at 340℃ ; (2) F(-) leaching was small in amount and completed within the first step at 200℃ and 12 hours ; (3) F(-) formation due to partial decomposition of PTFE became measurable from 340℃, was linear with time, and was remarkably accelerated at temperatures above 400℃ ; (4) migration of the enclosed NaCl (partly hydrolyzed during the course of the experiment) did not occur even at 410℃ ; but (5) osmosis of water caused a puncture of the test piece within 2 hours after the temperature reached 410℃. The test piece recovered after the run was found to be retaining the original luster and hardness. |
| 出版物タイトル | 岡山大学温泉研究所報告 |
| 発行日 | 1984-11-30 |
| 巻 | 55巻 |
| 開始ページ | 11 |
| 終了ページ | 14 |
| ISSN | 0369-7142 |
| 言語 | 日本語 |
| 論文のバージョン | publisher |
| NAID | 120002310961 |
| JaLCDOI | 10.18926/21085 |
|---|---|
| タイトル(別表記) | Automatic measurement of oxygen isotope ratio of water samples |
| フルテキストURL | pitsr_056_027_034.pdf |
| 著者 | 千葉 仁| 酒井 均| 安武 正敏| |
| 抄録 | The automatic sample preparation system for oxygen isotope analysis of natural water samples was constructed. The system is essentially a modification of that originally designed by W. Dansgaard in the University of Copenhagen. Sixty water samples of 5 ml each are automatically equilibrated with CO(2) of 30 ml NTP each within 4.5 hours. The equilibrated CO(2) gases are successively measured for their oxygen isotopic ratios by an automatic mas-sspectrometer, VG903. The time required for the measurement of the 60 CO(2) samples is about 15 hours; thus approximately 20 hours are required to complete the isotopic measurements of 60 water samples. The accuracy of the oxygen isotopic analyses is about 0.1%. The result of oxygen isotopic analyses by the automatic preparation system agrees with that of the conventional method within about +0.1%. The results indicate that the automatic preparation system is applicable for the oxygen isotope analysis of natural water samples. |
| 出版物タイトル | 岡山大学温泉研究所報告 |
| 発行日 | 1985-03-30 |
| 巻 | 56巻 |
| 開始ページ | 27 |
| 終了ページ | 34 |
| ISSN | 0369-7142 |
| 言語 | 日本語 |
| 論文のバージョン | publisher |
| NAID | 120002310952 |
| 著者 | 津田 敏秀| 三野 善央| 松岡 宏明| 谷原 真一| 馬場園 明| 山本 英二| |
|---|---|
| 発行日 | 1995-12-20 |
| 出版物タイトル | 環境制御 |
| 巻 | 17巻 |
| 資料タイプ | 紀要論文 |
| 著者 | 高柳 俊夫| 和田 栄子| 大島 光子| 本水 昌二| |
|---|---|
| 発行日 | 1995-12-20 |
| 出版物タイトル | 環境制御 |
| 巻 | 17巻 |
| 資料タイプ | 紀要論文 |
| 著者 | 佐橋 謙| 末永 明博| |
|---|---|
| 発行日 | 1995-12-20 |
| 出版物タイトル | 環境制御 |
| 巻 | 17巻 |
| 資料タイプ | 紀要論文 |
| 著者 | 李 啓熒| 大島 光子| 高柳 俊夫| 本水 昌二| |
|---|---|
| 発行日 | 1999-08 |
| 出版物タイトル | 環境制御 |
| 巻 | 21巻 |
| 資料タイプ | 紀要論文 |
| 著者 | 毛利 紫乃| 小野 芳朗| 河原 長美| |
|---|---|
| 発行日 | 2000-09 |
| 出版物タイトル | 環境制御 |
| 巻 | 22巻 |
| 資料タイプ | 紀要論文 |
| 著者 | 西垣 誠| 小松 満| 金 萬鎰| |
|---|---|
| 発行日 | 2003-08 |
| 出版物タイトル | 環境制御 |
| 巻 | 25巻 |
| 資料タイプ | 紀要論文 |
| 著者 | 難波 正義| |
|---|---|
| 発行日 | 2010-04-01 |
| 出版物タイトル | 岡山医学会雑誌 |
| 巻 | 122巻 |
| 号 | 1号 |
| 資料タイプ | 学術雑誌論文 |
| 著者 | 本水 昌二| Hazaki, Yoshito| 大島 光子| 桐栄 恭二| |
|---|---|
| 発行日 | 1987-06-10 |
| 出版物タイトル | Analytical Sciences |
| 巻 | 3巻 |
| 号 | 3号 |
| 資料タイプ | 学術雑誌論文 |
| 著者 | 本水 昌二| 大島 光子| 米田 直生| 岩知道 正| |
|---|---|
| 発行日 | 1990-04-10 |
| 出版物タイトル | Analytical Sciences |
| 巻 | 6巻 |
| 号 | 2号 |
| 資料タイプ | 学術雑誌論文 |
| 著者 | 本水 昌二| 大島 光子| Matsuda, Shin-ya| Obata, Yoshimitsu| Tanaka, Hiroshi| |
|---|---|
| 発行日 | 1992-10-10 |
| 出版物タイトル | Analytical Sciences |
| 巻 | 8巻 |
| 号 | 5号 |
| 資料タイプ | 学術雑誌論文 |
| 著者 | 本水 昌二| Susanto, Joko P.| 大島 光子| 三笠 博司| Hori, Yoshikazu| |
|---|---|
| 発行日 | 1995-02-10 |
| 出版物タイトル | Analytical Sciences |
| 巻 | 11巻 |
| 号 | 1号 |
| 資料タイプ | 学術雑誌論文 |
| 著者 | 樋口 慶郎| Tamanouchi Hiromitsu| 本水 昌二| |
|---|---|
| 発行日 | 1998-10-10 |
| 出版物タイトル | Analytical Sciences |
| 巻 | 14巻 |
| 号 | 5号 |
| 資料タイプ | 学術雑誌論文 |
| JaLCDOI | 10.18926/19962 |
|---|---|
| フルテキストURL | Mem_Fac_Eng_OU_44_73.pdf |
| 著者 | Imanaka, Hiroyuki| Tanaka, Soukichi| Feng, Bin| Imamura, Koreyoshi| Nakanishi, Kazuhiro| |
| 抄録 | We used modified Czapek-Dox (mCD) or dextrin-peptone-yeast extract (DPY) media to cultivate a filamentous fungus, Aspergillus oryzae IAM 2706 by three different cultivation methods, i.e., shaking-flask culture (SFC), agar-plate culture (APC), and membrane-surface liquid culture (MSLC), to identify the differences in cultivation behaviors and gene transcriptional profiles. The fungi cultivated by APC or MSLC secreted a greater number of different proteins/enzymes in larger quantities compared with fungi cultivated by SFC, particularly when DPY medium was used. In particular, the amounts of protease secreted by fungi cultivated via MSLC or APC were much greater compared with SFC. When mCD medium was used, α-amylase activity was barely detectable in all cultures while the activity was detected in MSLC and APC in a quantity that was several times higher than that in SFC using DPY medium. SDS-PAGE analysis and N-terminal amino acid sequences confirmed 6 proteins in the culture supernatants when DPY medium was used. Among these proteins oryzin (an alkaline protease) and α-amylase were detected at much higher levels in APC and MSLC compared with SFC, which was consistent with the measured activity of the secreted enzymes. However, when mCD medium was used, only oryzin was detected in significant amounts in MSLC and APC. Microarray analyses of the fungi cultivated by SFC, APC or MSLC using either mCD or DPY media indicated that the gene transcriptional profile of the MSLC sample was similar to that of the APC sample but different from that of the SFC sample. When mCD medium was used, most of the genes that were up-regulated 10-folds or greater in the MSLC sample relative to the SFC sample were unknown or predicted proteins. Transcription of the oryzin gene was only slightly up-regulated in the MSLC sample while transcription of the α-amylase gene was slightly down-regulated. On the other hand, when DPY medium was used, many known genes including the oryzin gene were up-regulated in the MSLC sample versus the SFC sample. |
| 出版物タイトル | Memoirs of the Faculty of Engineering, Okayama University |
| 発行日 | 2010-01 |
| 巻 | 44巻 |
| 開始ページ | 73 |
| 終了ページ | 83 |
| ISSN | 1349-6115 |
| 言語 | 英語 |
| 論文のバージョン | publisher |
| NAID | 120002309053 |
| 著者 | 沢谷 郁夫| 大島 光子| 本水 昌二| 桐栄 恭二| |
|---|---|
| 発行日 | 1984-02-05 |
| 出版物タイトル | 分析化学 |
| 巻 | 33巻 |
| 号 | 2号 |
| 資料タイプ | 学術雑誌論文 |