ID | 61860 |
フルテキストURL | |
著者 |
Shimizu, Hiroaki
Department of Oral Rehabilitation and Regenerative Medicine, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Sciences
Arakawa, Hikaru
Department of Oral Rehabilitation and Regenerative Medicine, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Sciences
Mino, Takuya
Department of Oral Rehabilitation and Regenerative Medicine, Okayama University Graduate School of Medicine, Dentistry, and Pharmaceutical Sciences
Kaken ID
researchmap
Kurosaki, Yoko
Department of Oral Rehabilitation and Regenerative Medicine, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Sciences
Tokumoto, Kana
Department of Oral Rehabilitation and Regenerative Medicine, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Sciences
Kuboki, Takuo
Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Sciences
ORCID
Kaken ID
publons
researchmap
|
抄録 | Patients: The patient was a 55-year-old woman with left upper molar free-end edentulism and 9 full cast metal crowns in her mouth. Three three-dimensional (3D) images were superimposed: a computed tomography (CT) image with the patient wearing the CT-matching template (CTMT) with six glass ceramic markers, which hardly generate any artifacts, on the template surface, and oral plaster model surfaces with and without CTMTs. Metal artifacts were automatically removed by a Boolean operation identifying unrealistic images outside the oral plaster model surface. After the preoperative simulation, fully guided oral implant surgery was performed. Two implant bodies were placed in the left upper edentulism. The placement errors calculated by comparing the preoperative simulation and actual implant placement were then assessed by a software program using the 3D-CT bone morphology as a reference. The 3D deviations between the preoperative simulation and actual placement at the entry of the implant body were a maximum 0.48 mm and minimum 0.26 mm. Those at the tip of the implant body were a maximum 0.56 mm and a minimum 0.25 mm.
Discussion: In this case, the maximum 3D deviations at the entry and tip section were less than in previous studies using double CT. Conclusions: Accurate image fusion utilizing CTMT with new reference markers was possible for a patient with many metal restorations. Using a surgical guide manufactured by the new matching methodology (modified single CT scan method), implant placement deviation can be minimized in patients with many metal restorations. |
キーワード | Computer-assisted surgery
Computer-aided design
Tomography
X-Ray Computed
Artifact
|
備考 | This is an Accepted Manuscript of an article published by Japan Prosthodontic Society
|
発行日 | 2021-02-24
|
出版物タイトル |
Journal of Prosthodontic Research
|
巻 | 65巻
|
号 | 1号
|
出版者 | Japan Prosthodontic Society
|
開始ページ | 125
|
終了ページ | 129
|
ISSN | 1883-1958
|
NCID | AA12395171
|
資料タイプ |
学術雑誌論文
|
言語 |
英語
|
OAI-PMH Set |
岡山大学
|
論文のバージョン | author
|
PubMed ID | |
NAID | |
DOI | |
Web of Science KeyUT | |
関連URL | isVersionOf https://doi.org/10.2186/jpr.jpor_2019_429
|
ライセンス | https://creativecommons.org/licenses/by/4.0/deed.ja
|