このエントリーをはてなブックマークに追加


ID 40148
JaLCDOI
Sort Key
3
タイトル(別表記)
The effect of pH of water on the measurement of oxygen isotopic ratio by means of CO(2)-H(2)O isotopic exchange technique
フルテキストURL
著者
松葉谷 治 岡山大学温泉研究所温泉化学部門
抄録
The effect of pH of water on the measurement of oxygen isotopic ratio by means of CO(2)-H(2)O isotopic exchange technique was studied. In this study, a new type of reaction vessel was used (Fig. 1). The reaction time for equilibration using this new reaction vessel was nearly equal to that in the previous study (Fig. 2). The oxygen isotopic ratios of each two samples of pH 2, 4, 7, 8, 9, and 10 were measured. There is no significant difference between the observed δ(18)O values of these samples (Table 1). Therefore it is concluded that the effect of pH of water needs not to be taken into account on the measurement of oxygen isotopic ratio by means of CO(2)-H(2)O isotopic exchange technique.
備考
原著論文 (Original Paper)
出版物タイトル
岡山大学温泉研究所報告
発行日
1972-03-25
巻
41巻
出版者
岡山大学温泉研究所
出版者(別表記)
Institute for Thermal Spring Research, Okayama University
開始ページ
1
終了ページ
2
ISSN
0369-7142
NCID
AN00032853
資料タイプ
紀要論文
OAI-PMH Set
岡山大学
言語
日本語
論文のバージョン
publisher
NAID
Eprints Journal Name
mmc