| ID | 40148 |
| JaLCDOI | |
| Sort Key | 3
|
| タイトル(別表記) | The effect of pH of water on the measurement of oxygen isotopic ratio by means of CO(2)-H(2)O isotopic exchange technique
|
| フルテキストURL | |
| 著者 |
松葉谷 治
岡山大学温泉研究所温泉化学部門
|
| 抄録 | The effect of pH of water on the measurement of oxygen isotopic ratio by means of CO(2)-H(2)O isotopic exchange technique was studied. In this study, a new type of reaction vessel was used (Fig. 1). The reaction time for equilibration using this new reaction vessel was nearly equal to that in the previous study (Fig. 2). The oxygen isotopic ratios of each two samples of pH 2, 4, 7, 8, 9, and 10 were measured. There is no significant difference between the observed δ(18)O values of these samples (Table 1). Therefore it is concluded that the effect of pH of water needs not to be taken into account on the measurement of oxygen isotopic ratio by means of CO(2)-H(2)O isotopic exchange technique.
|
| 備考 | 原著論文 (Original Paper)
|
| 出版物タイトル |
岡山大学温泉研究所報告
|
| 発行日 | 1972-03-25
|
| 巻 | 41巻
|
| 出版者 | 岡山大学温泉研究所
|
| 出版者(別表記) | Institute for Thermal Spring Research, Okayama University
|
| 開始ページ | 1
|
| 終了ページ | 2
|
| ISSN | 0369-7142
|
| NCID | AN00032853
|
| 資料タイプ |
紀要論文
|
| OAI-PMH Set |
岡山大学
|
| 言語 |
日本語
|
| 論文のバージョン | publisher
|
| NAID | |
| Eprints Journal Name | mmc
|