ID | 56645 |
JaLCDOI | |
フルテキストURL | |
著者 |
Iida, Atsuyoshi
Department of Emergency and Critical Care and Disaster Medicine, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Sciences
Naito, Hiromichi
Department of Emergency and Critical Care and Disaster Medicine, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Sciences
Yorifuji, Takashi
Department of Human Ecology, Okayama University Graduate School of Environmental and Life Science
Zamami, Yoshito
Department of Clinical Pharmacy, Institute of Biomedical Sciences, Tokushima University Graduate School
Yamada, Akane
Department of Pharmacy, Okayama University Hospital
Koga, Tadashi
Drug Safety Research Laboratories, Shin Nippon Biomedical Laboratories, Ltd.
Imai, Toru
Department of Pharmacy, Nihon University Itabashi Hospital
Sendo, Toshiaki
Department of Pharmacy, Okayama University Hospital
Nakao, Atsunori
Department of Emergency and Critical Care and Disaster Medicine, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Sciences
Ichiba, Shingo
Department of Surgical Intensive Care Medicine, Nippon Medical School Hospital
|
抄録 | Sedatives are administered during extracorporeal membrane oxygenation (ECMO) therapy to ensure patient safety, reduce the metabolic rate and correct the oxygen supply-demand balance. However, the concentrations of sedatives can be decreased due to absorption into the circuit. This study examined factors affecting the absorption of a commonly used sedative, midazolam (MDZ). Using multiple ex vivo simulation models, three factors that may influence MDZ levels in the ECMO circuit were examined: polyvinyl chloride (PVC) tubing in the circuit, use of a membrane oxygenator in the circuit, and heparin coating of the circuit. We also assessed changes in drug concentration when MDZ was re-injected in a circuit. The MDZ level decreased to approximately 60% of the initial concentration in simulated circuits within the first 30 minutes. The strongest factor in this phenomenon was contact with the PVC tubing. Membrane oxygenator use tended to increase MDZ loss, whereas heparin circuit coating had no influence on MDZ absorption. Similar results were obtained when a second dose of MDZ was injected to the second-use circuits.
|
キーワード | sedatives
ECMO
polyvinyl chloride
pharmacokinetics
pharmacodynamics
|
Amo Type | Original Article
|
出版物タイトル |
Acta Medica Okayama
|
発行日 | 2019-04
|
巻 | 73巻
|
号 | 2号
|
出版者 | Okayama University Medical School
|
開始ページ | 101
|
終了ページ | 107
|
ISSN | 0386-300X
|
NCID | AA00508441
|
資料タイプ |
学術雑誌論文
|
言語 |
英語
|
著作権者 | CopyrightⒸ 2019 by Okayama University Medical School
|
論文のバージョン | publisher
|
査読 |
有り
|
PubMed ID |