
| ID | 69470 |
| フルテキストURL | |
| 著者 |
Kawada, Koki
Department of Orthopaedic Surgery, Faculty of Medicine, Dentistry and Pharmaceutical Sciences, Okayama University
Yokoyama, Yusuke
Department of Orthopaedic Surgery, Faculty of Medicine, Dentistry and Pharmaceutical Sciences, Okayama University
Tetsunaga, Tomonori
Department of Orthopaedic Surgery, Faculty of Medicine, Dentistry and Pharmaceutical Sciences, Okayama University
ORCID
Kaken ID
Yamada, Kazuki
Department of Orthopaedic Surgery, Faculty of Medicine, Dentistry and Pharmaceutical Sciences, Okayama University
Okazaki, Yuki
Department of Orthopaedic Surgery, Faculty of Medicine, Dentistry and Pharmaceutical Sciences, Okayama University
Kohara, Toshiki
Department of Orthopaedic Surgery, Faculty of Medicine, Dentistry and Pharmaceutical Sciences, Okayama University
Ozaki, Toshifumi
Department of Orthopaedic Surgery, Faculty of Medicine, Dentistry and Pharmaceutical Sciences, Okayama University
Kaken ID
publons
researchmap
|
| 抄録 | Introduction Few studies have examined how the component placement angles in total knee arthroplasty (TKA) affect mid- to long-term clinical outcomes. This study investigated the influence of coronal and sagittal plane component placement angles on mid- to long-term outcomes in mechanical alignment TKA.
Materials and Methods Forty-eight knees undergoing TKA using the FINE Total Knee System were evaluated for range of motion (ROM) preoperatively. Both ROM and clinical scores were evaluated at 3 and 5 years postoperatively and at the final follow-up (average 8-year). The valgus (alpha) and flexion (gamma) angles of the femoral component, and the varus (beta) and posterior tilt (sigma) angles of the tibial component were evaluated. Correlations between radiographic assessments, knee ROM, and clinical scores were assessed using Spearman's correlation coefficient. Results The alpha angle was negatively correlated with the knee flexion angle (r = − 0.323, p = 0.025) and ROM (r = − 0.352, p = 0.014), and the sigma angle was negatively correlated with the Knee Injury and Osteoarthritis Outcome Score (KOOS)-Symptoms at 3 years postoperatively (r = − 0.304, p = 0.036). The alpha angle was negatively correlated with the knee flexion angle (r = − 0.357, p = 0.013), ROM (r = − 0.337, p = 0.019), and KOOS-Sports and Recreation function (r = − 0.349, p = 0.015), and positively correlated with the Visual Analog Scare pain score (r = 0.307, p = 0.034) at the final follow-up. The beta angle was positively correlated with KOOS-Pain (r = 0.303, p = 0.036) and KOOS-Symptoms (r = 0.397, p = 0.005) at the final follow-up. Conclusions Valgus placement of the femoral component and varus placement of the tibial component in the FINE Total Knee System negatively impacted clinical scores at an average 8-year follow-up. |
| キーワード | Total knee arthroplasty
Component placement
Varus
Valgus
Clinical outcome
|
| 発行日 | 2025-09-30
|
| 出版物タイトル |
Archives of Orthopaedic and Trauma Surgery
|
| 巻 | 145巻
|
| 号 | 1号
|
| 出版者 | Springer Science and Business Media LLC
|
| 開始ページ | 457
|
| ISSN | 1434-3916
|
| 資料タイプ |
学術雑誌論文
|
| 言語 |
英語
|
| OAI-PMH Set |
岡山大学
|
| 著作権者 | © The Author(s) 2025
|
| 論文のバージョン | publisher
|
| PubMed ID | |
| DOI | |
| Web of Science KeyUT | |
| 関連URL | isVersionOf https://doi.org/10.1007/s00402-025-06080-8
|
| ライセンス | http://creativecommons.org/licenses/by/4.0/
|
| Citation | Kawada, K., Yokoyama, Y., Tetsunaga, T. et al. Component placement angles in total knee arthroplasty affect mid- to long-term clinical results: an average 8-year follow-up study. Arch Orthop Trauma Surg 145, 457 (2025). https://doi.org/10.1007/s00402-025-06080-8
|
| 助成情報 |
( 国立大学法人岡山大学 / Okayama University )
|