ID | 32186 |
JaLCDOI | |
フルテキストURL | |
著者 |
Furuno, Katsushi
Okayama University
Gomita, Yutaka
Okayama University
Araki, Yasunori
Okayama University
Fukuda, Tamotu
Ehime University Medical Scool
|
抄録 | We studied the use of high-performance liquid chromatography (HPLC), using a solid phase extraction column (Bond Elut cartridge column), for the simple, rapid and sensitive determination of serum clonazepam levels in epileptic patients. Extracted aliquots were analyzed by HPLC, using a reverse phase ODS column (mu-Bondapak C18). The analytical mean recovery of clonazepam added to the blank serum averaged 99.9%. The detection limit was as high as approximately 2 ng/ml in the serum. The reproducibilities were 2.3-8.6 CV % in the within-day assay and 6.5 CV % in the between-day assay, indicating that the analysis method was effective in the determination of clonazepam serum levels. Accordingly, we suggest that the present method, using a solid phase extraction column, may be useful for the routine monitoring of clonazepam serum levels in epileptic patients.</P> |
キーワード | clonazepam serum levels
epileptic patient
therapeutic drug monitoring
solid-phase extraction
HPLC
|
Amo Type | Article
|
出版物タイトル |
Acta Medica Okayama
|
発行日 | 1991-04
|
巻 | 45巻
|
号 | 2号
|
出版者 | Okayama University Medical School
|
開始ページ | 123
|
終了ページ | 127
|
ISSN | 0386-300X
|
NCID | AA00508441
|
資料タイプ |
学術雑誌論文
|
言語 |
英語
|
論文のバージョン | publisher
|
査読 |
有り
|
PubMed ID | |
Web of Science KeyUT |