このエントリーをはてなブックマークに追加


ID 67598
フルテキストURL
著者
FUJITA, Juntaro Department of Neurological Surgery, Okayama University Faculty of Medicine, Dentistry and Pharmaceutical Sciences
HIROTSUNE, Nobuyuki Department of Neurosurgery and Neuroendovascular Surgery, Hiroshima City Hiroshima Citizens Hospital
MATSUDA, Yuki Department of Neurosurgery, Miyoshi Central Hospital
HAMASAKI, Osamu Department of Neurosurgery, Miyoshi Central Hospital
FUKUDA, Shoichi Department of Neurosurgery and Neuroendovascular Surgery, Hiroshima City Hiroshima Citizens Hospital
OKADA, Yoshihiro Department of Neurosurgery and Neuroendovascular Surgery, Hiroshima City Hiroshima Citizens Hospital
KOBASHI, Aiko Department of Neurosurgery and Neuroendovascular Surgery, Hiroshima City Hiroshima Citizens Hospital
NISHIGAKI, Shohei Department of Neurosurgery and Neuroendovascular Surgery, Hiroshima City Hiroshima Citizens Hospital
MAKINO, Keigo Department of Neurosurgery and Neuroendovascular Surgery, Hiroshima City Hiroshima Citizens Hospital
TOMITA, Yusuke Department of Neurosurgery and Neuroendovascular Surgery, Hiroshima City Hiroshima Citizens Hospital
KIDANI, Naoya Department of Neurosurgery and Neuroendovascular Surgery, Hiroshima City Hiroshima Citizens Hospital
MURAOKA, Kenichiro Department of Neurosurgery and Neuroendovascular Surgery, Hiroshima City Hiroshima Citizens Hospital
NISHINO, Shigeki Department of Neurosurgery and Neuroendovascular Surgery, Hiroshima City Hiroshima Citizens Hospital
抄録
Failure to retrieve a distal filter-based embolic protection device (EPD) is a potential complication of carotid artery stenting. This may be caused by trapping of the proximal marker of the EPD within the stent tip marker. Maintaining an adequate distance between the two can prevent this. We examined the behavior of several stent-filter-based EPD combinations, focusing on their propensity to become trapped or disengage in vitro. Four physicians subjectively rated the force required to result in trapping using a 5-point scale. Moreover, the force required to disengage trapped devices was evaluated. The Casper stent & horbar;Spider FX EPD combination was difficult to disengage when entrapment occurred, which suggested that this phenomenon tended to occur with this combination. The stent tip marker of the closed-cell stents advanced as they shortened, which may be a unique feature of closed-cell stents. Although trapping is uncommon, it can cause serious complications. To prevent these complications, device characteristics should be well understood before they are used in patients.
キーワード
carotid artery stenting
distal filter-based embolic protection device
complication
発行日
2024
出版物タイトル
Neurologia medico-chirurgica
64巻
10号
出版者
The Japan Neurosurgical Society
開始ページ
382
終了ページ
386
ISSN
0470-8105
NCID
AN00358613
資料タイプ
学術雑誌論文
言語
英語
OAI-PMH Set
岡山大学
著作権者
© 2024 The Japan Neurosurgical Society
論文のバージョン
publisher
PubMed ID
DOI
Web of Science KeyUT
関連URL
isVersionOf https://doi.org/10.2176/jns-nmc.2024-0013
ライセンス
https://creativecommons.org/licenses/by-nc-nd/4.0/