ID | 61214 |
JaLCDOI | |
フルテキストURL | |
著者 |
Morimoto, Yusuke
Department of Orthopaedic Surgery, Nihon University School of Medicine
Komatsu, Taichi
Department of Orthopaedic Surgery, Nihon University School of Medicine
Tokuhashi, Yasuaki
Department of Orthopaedic Surgery, Nihon University School of Medicine
|
抄録 | Active treatment with intramedullary screw fixation is now common for athletes with Jones fracture. Outcomes are generally good, but complications can occur. We report 4 rare complications of intramedullary screw fixa-tion. Two cases developed osteomyelitis and pseudarthrosis caused by thermal necrosis. In the other two cases, screw-related complications occurred during the insertion of the tapered headless screw. Although thermal necrosis and screw insertion failures are considered rare complications and not widely reported in the litera-ture, they do occur occasionally. Knowing the mechanisms underlying these complications could help prevent them, and knowing their course could lead caregivers to appropriate interventions when they do occur.
|
キーワード | Jones fracture
thermal necrosis
tapered headless screw
|
Amo Type | Case Report
|
出版物タイトル |
Acta Medica Okayama
|
発行日 | 2020-12
|
巻 | 74巻
|
号 | 6号
|
出版者 | Okayama University Medical School
|
開始ページ | 537
|
終了ページ | 544
|
ISSN | 0386-300X
|
NCID | AA00508441
|
資料タイプ |
学術雑誌論文
|
言語 |
英語
|
著作権者 | CopyrightⒸ 2020 by Okayama University Medical School
|
論文のバージョン | publisher
|
査読 |
有り
|
PubMed ID | |
Web of Science KeyUT | |
NAID |