
| ID | 71338 |
| JaLCDOI | |
| フルテキストURL | |
| 著者 |
Komuta, Yuki
Division of Orthopedic Surgery, Graduate School of Medical and Dental Sciences, Niigata University
Imai, Norio
Division of Comprehensive Musculoskeletal Medicine, Graduate School of Medical and Dental Sciences, Niigata University
Homma, Daisuke
Division of Orthopedic Surgery, Graduate School of Medical and Dental Sciences, Niigata University
Funayama, Kazuhisa
Division of Legal Medicine, Graduate School of Medical and Dental Sciences, Niigata University
Hirano, Yuki
Division of Orthopedic Surgery, Graduate School of Medical and Dental Sciences, Niigata University
Horigome, Yoji
Division of Comprehensive Musculoskeletal Medicine, Graduate School of Medical and Dental Sciences, Niigata University
Minato, Izumi
Department of Orthopedic Surgery, Niigata Rinko Hospital
Kawashima, Hiroyuki
Division of Orthopedic Surgery, Graduate School of Medical and Dental Sciences, Niigata University
|
| 抄録 | The “CR Alignment” function was recently introduced in ZedHip®, the hip joint module of ZedView®, to evaluate pelvic tilt in non-supine positions via two-dimensional (2D)‒3D matching using radiographs. However, its ccuracy has not been validated. This study therefore evaluated the accuracy of pelvic tilt measurements using the CR Alignment function in dry pelvic bone specimens. Two cadaveric pelvic bone models were placed in nine orientations (anterior/posterior tilt and left/right rotation). Both radiographic and CT images were acquired in each position. In Study 1, pelvic tilt measured directly from CT images was defined as the “true value.” Three observers used the CR Alignment function to calculate pelvic tilt on radiographs, and measurement errors were determined relative to the true values. In Study 2, measurement errors were compared between matched (same position) and mismatched (different position) imaging. In Study 1, the mean measurement error was 1.28±0.64°. Intra- and interobserver intraclass correlation coefficients were 0.996-0.998 and 0.997, respectively. In Study 2, the mean errors were 1.20±0.88° (matched) and 1.32±1.03° (mismatched). This software exhibited high accuracy and reproducibility in 2D‒3D matching of pelvic tilt, with lower variability under matched acquisition, demonstrating its utility for pre- and postoperative assessment in joint arthroplasty.
|
| キーワード | total hip arthroplasty
pelvic tilt
three-dimensional planning software
two-dimensional and threedimensional matching
radiographic analysis
|
| Amo Type | Original Article
|
| 出版物タイトル |
Acta Medica Okayama
|
| 発行日 | 2026-10
|
| 巻 | 80巻
|
| 号 | 5号
|
| 出版者 | Okayama University Medical School
|
| 開始ページ | 289
|
| 終了ページ | 298
|
| ISSN | 0386-300X
|
| NCID | AA00508441
|
| 資料タイプ |
学術雑誌論文
|
| 言語 |
英語
|
| 著作権者 | Copyright Ⓒ 2026 by Okayama University Medical School
|
| 論文のバージョン | publisher
|
| 査読 |
有り
|