<p>This paper presents the control and performance of a pulse-density-modulated (PDM) series-resonant voltage-source inverter developed for corona discharge processes. The PDM inverter produces either a square-wave AC-voltage state or a zero-voltage state at its AC terminals to control the average output voltage under constant DC voltage and operating frequency. This results in a wide range of power control from 0.5% to 100%, even in the corona discharge load with a strong nonlinear characteristic. A 30 kHz 6 kW surface treatment system consisting of a voltage-source PDM inverter, a step-up transformer, and a corona discharge treater shows the establishment of a stable corona discharge in an extremely wide range of power control and, therefore, succeeds in performing both strong and weak surface treatment processes for film </p>

キーワード
DC-AC power convertors
corona
invertors
load (electric)
power transformers
resonant
power convertors
surface treatment
voltage control
備考
Digital Object Identifier: 10.1109/28.767013
Published with permission from the copyright holder.this is the institute's copy, as published in Industry Applications, IEEE Transactions on, May-June 1999, Volume 35, Issue 3, Page(s):621-627.
Publisher URL:http://dx.doi.org/10.1109/28.767013
Copyright © 1999 IEEE. All rights reserved.