ID | 34108 |
フルテキストURL | |
著者 |
Fujita, Hideaki
Okayama University
Akagi, Hirofumi
Okayama University
|
抄録 | <p>This paper presents the control and performance of a pulse-density-modulated (PDM) series-resonant voltage-source inverter developed for corona discharge processes. The PDM inverter produces either a square-wave AC-voltage state or a zero-voltage state at its AC terminals to control the average output voltage under constant DC voltage and operating frequency. This results in a wide range of power control from 0.5% to 100%, even in the corona discharge load with a strong nonlinear characteristic. A 30 kHz 6 kW surface treatment system consisting of a voltage-source PDM inverter, a step-up transformer, and a corona discharge treater shows the establishment of a stable corona discharge in an extremely wide range of power control and, therefore, succeeds in performing both strong and weak surface treatment processes for film </p> |
キーワード | DC-AC power convertors
corona
invertors
load (electric)
power transformers
resonant
power convertors
surface treatment
voltage control
|
備考 | Digital Object Identifier: 10.1109/28.767013
Published with permission from the copyright holder.this is the institute's copy, as published in Industry Applications, IEEE Transactions on, May-June 1999, Volume 35, Issue 3, Page(s):621-627. Publisher URL:http://dx.doi.org/10.1109/28.767013 Copyright © 1999 IEEE. All rights reserved. |
発行日 | 1999-6
|
出版物タイトル |
Industry Applications
|
巻 | 35巻
|
号 | 3号
|
資料タイプ |
学術雑誌論文
|
言語 |
英語
|
査読 |
有り
|
DOI | |
Submission Path | electrical_engineering/19
|