フルテキストURL
fulltext.pdf 1.69 MB
著者
Tetsunaga, Tomonori Department of Musculoskeletal Health Promotion, Faculty of Medicine, Dentistry and Pharmaceutical Sciences, Okayama University ORCID Kaken ID
Tetsunaga, Tomoko Department of Orthopaedic Surgery, Okayama University Hospital
Yamada, Kazuki Department of Medical Materials for Musculoskeletal Reconstruction, Faculty of Medicine, Dentistry and Pharmaceutical Sciences, Okayama University
Koura, Takashi Department of Medical Materials for Musculoskeletal Reconstruction, Faculty of Medicine, Dentistry and Pharmaceutical Sciences, Okayama University
Inoue, Tomohiro Department of Medical Materials for Musculoskeletal Reconstruction, Faculty of Medicine, Dentistry and Pharmaceutical Sciences, Okayama University
Okuda, Ryuichiro Department of Medical Materials for Musculoskeletal Reconstruction, Faculty of Medicine, Dentistry and Pharmaceutical Sciences, Okayama University
Masada, Yasutaka Department of Medical Materials for Musculoskeletal Reconstruction, Faculty of Medicine, Dentistry and Pharmaceutical Sciences, Okayama University
Muguruma, Sho Department of Orthopaedics, Okayama Medical Center
Okazaki, Yuki Department of Orthopaedics, Faculty of Medicine, Dentistry and Pharmaceutical Sciences, Okayama University
Ozaki, Toshifumi Department of Orthopaedic Surgery, Faculty of Medicine, Dentistry and Pharmaceutical Sciences, Okayama University Kaken ID publons researchmap
抄録
Background Navigation systems, including portable navigation systems, used for total hip arthroplasty (THA) are useful for achieving higher cup alignment accuracy. NAVBIT, a newly available portable navigation system, uses a unique registration method, the table tilt registration. However, its accuracy is unclear. This retrospective study aimed to investigate whether THA with a portable navigation system in the lateral position with the flip technique is more accurate than THA with a cup goniometer in the supine or lateral positions.
Methodology This study included 96 consecutive patients (77 women, 19 men) who underwent primary cementless THA using either a portable navigation system in the lateral position with the flip technique or a cup goniometer in the supine or lateral positions. The average age of the patients was 66.8 years (range = 29-91) and the average body mass index was 24.6 kg/m2 (range = 17.5-39.9). The accuracy of cup orientation was compared among the three groups.
Results The absolute values of the difference in cup inclination and anteversion with the NAVBIT (2.1 ± 1.7°, 2.0 ± 1.4°) were smaller than that with the cup goniometer in the supine (3.4 ± 2.4°, 3.4 ± 2.2°) and lateral decubitus positions (3.4 ± 2.5°, 5.0 ± 3.5°). Overall, 91%, 64.5%, and 56.3% were within 5° of the target angles in the navigation, supine goniometer, and lateral goniometer groups, respectively.
Conclusions The accuracy of cup alignment with the portable navigation system using the flip technique was significantly higher than that with the cup goniometer in the supine and lateral decubitus positions.
キーワード
hip
navigation system
portable navigation
retrospective study
total hip arthroplasty (tha)
発行日
2024-11-21
出版物タイトル
Cureus
16巻
11号
出版者
Springer Science and Business Media LLC
開始ページ
e74176
ISSN
2168-8184
資料タイプ
学術雑誌論文
言語
英語
OAI-PMH Set
岡山大学
論文のバージョン
publisher
PubMed ID
DOI
ライセンス
https://creativecommons.org/licenses/by/4.0/
Citation
Tetsunaga T, Tetsunaga T, Yamada K, et al. (November 21, 2024) Accuracy of Cup Alignment in Total Hip Arthroplasty: A Comparison Between Portable Navigation and Goniometer. Cureus 16(11): e74176. doi:10.7759/cureus.74176