| フルテキストURL | |
| 著者 |
Tetsunaga, Tomonori
Department of Musculoskeletal Health Promotion, Faculty of Medicine, Dentistry and Pharmaceutical Sciences, Okayama University
ORCID
Kaken ID
Tetsunaga, Tomoko
Department of Orthopaedic Surgery, Okayama University Hospital
Yamada, Kazuki
Department of Medical Materials for Musculoskeletal Reconstruction, Faculty of Medicine, Dentistry and Pharmaceutical Sciences, Okayama University
Koura, Takashi
Department of Medical Materials for Musculoskeletal Reconstruction, Faculty of Medicine, Dentistry and Pharmaceutical Sciences, Okayama University
Inoue, Tomohiro
Department of Medical Materials for Musculoskeletal Reconstruction, Faculty of Medicine, Dentistry and Pharmaceutical Sciences, Okayama University
Okuda, Ryuichiro
Department of Medical Materials for Musculoskeletal Reconstruction, Faculty of Medicine, Dentistry and Pharmaceutical Sciences, Okayama University
Masada, Yasutaka
Department of Medical Materials for Musculoskeletal Reconstruction, Faculty of Medicine, Dentistry and Pharmaceutical Sciences, Okayama University
Muguruma, Sho
Department of Orthopaedics, Okayama Medical Center
Okazaki, Yuki
Department of Orthopaedics, Faculty of Medicine, Dentistry and Pharmaceutical Sciences, Okayama University
Ozaki, Toshifumi
Department of Orthopaedic Surgery, Faculty of Medicine, Dentistry and Pharmaceutical Sciences, Okayama University
Kaken ID
publons
researchmap
|
| 抄録 | Background Navigation systems, including portable navigation systems, used for total hip arthroplasty (THA) are useful for achieving higher cup alignment accuracy. NAVBIT, a newly available portable navigation system, uses a unique registration method, the table tilt registration. However, its accuracy is unclear. This retrospective study aimed to investigate whether THA with a portable navigation system in the lateral position with the flip technique is more accurate than THA with a cup goniometer in the supine or lateral positions.
Methodology This study included 96 consecutive patients (77 women, 19 men) who underwent primary cementless THA using either a portable navigation system in the lateral position with the flip technique or a cup goniometer in the supine or lateral positions. The average age of the patients was 66.8 years (range = 29-91) and the average body mass index was 24.6 kg/m2 (range = 17.5-39.9). The accuracy of cup orientation was compared among the three groups. Results The absolute values of the difference in cup inclination and anteversion with the NAVBIT (2.1 ± 1.7°, 2.0 ± 1.4°) were smaller than that with the cup goniometer in the supine (3.4 ± 2.4°, 3.4 ± 2.2°) and lateral decubitus positions (3.4 ± 2.5°, 5.0 ± 3.5°). Overall, 91%, 64.5%, and 56.3% were within 5° of the target angles in the navigation, supine goniometer, and lateral goniometer groups, respectively. Conclusions The accuracy of cup alignment with the portable navigation system using the flip technique was significantly higher than that with the cup goniometer in the supine and lateral decubitus positions. |
| キーワード | hip
navigation system
portable navigation
retrospective study
total hip arthroplasty (tha)
|
| 発行日 | 2024-11-21
|
| 出版物タイトル |
Cureus
|
| 巻 | 16巻
|
| 号 | 11号
|
| 出版者 | Springer Science and Business Media LLC
|
| 開始ページ | e74176
|
| ISSN | 2168-8184
|
| 資料タイプ |
学術雑誌論文
|
| 言語 |
英語
|
| OAI-PMH Set |
岡山大学
|
| 著作権者 | © Copyright 2024 Tetsunaga et al.
|
| 論文のバージョン | publisher
|
| PubMed ID | |
| DOI | |
| 関連URL | isVersionOf https://doi.org/10.7759/cureus.74176
|
| ライセンス | https://creativecommons.org/licenses/by/4.0/
|
| Citation | Tetsunaga T, Tetsunaga T, Yamada K, et al. (November 21, 2024) Accuracy of Cup Alignment in Total Hip Arthroplasty: A Comparison Between Portable Navigation and Goniometer. Cureus 16(11): e74176. doi:10.7759/cureus.74176
|