<?xml version="1.0" encoding="Windows-31J"?>
<ArticleSet xmlns="http://www.openarchives.org/OAI/2.0/">
  <Article>
    <Journal>
      <PublisherName>Okayama University Medical School</PublisherName>
      <JournalTitle>Acta Medica Okayama</JournalTitle>
      <Issn>0386-300X</Issn>
      <Volume>75</Volume>
      <Issue>1</Issue>
      <PubDate PubStatus="ppublish">
        <Year>2021</Year>
        <Month/>
      </PubDate>
    </Journal>
    <ArticleTitle>Minimally Invasive Spinal Stabilization with Denosumab before Total Spondylectomy for a Collapsing Lower Lumbar Spinal Giant Cell Tumor</ArticleTitle>
    <FirstPage LZero="delete">95</FirstPage>
    <LastPage>101</LastPage>
    <Language>EN</Language>
    <AuthorList>
      <Author>
        <FirstName EmptyYN="N">Keitaro</FirstName>
        <LastName>Minato</LastName>
        <Affiliation>Division of Orthopedic Surgery, Department of Regenerative and Transplant Medicine, Niigata University Graduate School of Medical and Dental Sciences</Affiliation>
      </Author>
      <Author>
        <FirstName EmptyYN="N">Toru</FirstName>
        <LastName>Hirano</LastName>
        <Affiliation>Division of Orthopedic Surgery, Department of Regenerative and Transplant Medicine, Niigata University Graduate School of Medical and Dental Sciences</Affiliation>
      </Author>
      <Author>
        <FirstName EmptyYN="N">Hiroyuki</FirstName>
        <LastName>Kawashima</LastName>
        <Affiliation>Division of Orthopedic Surgery, Department of Regenerative and Transplant Medicine, Niigata University Graduate School of Medical and Dental Sciences</Affiliation>
      </Author>
      <Author>
        <FirstName EmptyYN="N">Tetsuro</FirstName>
        <LastName>Yamagishi</LastName>
        <Affiliation>Division of Orthopedic Surgery, Department of Regenerative and Transplant Medicine, Niigata University Graduate School of Medical and Dental Sciences</Affiliation>
      </Author>
      <Author>
        <FirstName EmptyYN="N">Keigo</FirstName>
        <LastName>Watanabe</LastName>
        <Affiliation>Division of Orthopedic Surgery, Department of Regenerative and Transplant Medicine, Niigata University Graduate School of Medical and Dental Sciences</Affiliation>
      </Author>
      <Author>
        <FirstName EmptyYN="N">Masayuki</FirstName>
        <LastName>Ohashi</LastName>
        <Affiliation>Division of Orthopedic Surgery, Department of Regenerative and Transplant Medicine, Niigata University Graduate School of Medical and Dental Sciences</Affiliation>
      </Author>
      <Author>
        <FirstName EmptyYN="N">Akira</FirstName>
        <LastName>Ogose</LastName>
        <Affiliation>Department of Orthopedic Surgery, Uonuma Kikan Hospital</Affiliation>
      </Author>
      <Author>
        <FirstName EmptyYN="N">Naoto</FirstName>
        <LastName>Endo</LastName>
        <Affiliation>Division of Orthopedic Surgery, Department of Regenerative and Transplant Medicine, Niigata University Graduate School of Medical and Dental Sciences</Affiliation>
      </Author>
    </AuthorList>
    <PublicationType>Case Report</PublicationType>
    <ArticleIdList>
      <ArticleId IdType="doi">/10.18926/AMO/61442</ArticleId>
    </ArticleIdList>
    <Abstract>A 21-year-old man consulted our hospital for treatment of a spinal giant cell tumor (GCT) of Enneking stage III. Lower lumbar-spine tumors and severe spinal canal stenosis are associated with high risk for surgical mor-bidity. Stability was temporarily secured with a percutaneous pedicle screw fixation in combination with deno-sumab, which shrank the tumor. Total en bloc spondylectomy was then performed 6 months after initiation of denosumab, and the patient was followed for 3 years. There was no local recurrence, and bony fusion was obtained. Minimally invasive surgery and denosumab allowed safer and easier treatment of a collapsing lower lumbar extra-compartmental GCT.</Abstract>
    <CoiStatement>No potential conflict of interest relevant to this article was reported.</CoiStatement>
    <ObjectList>
      <Object Type="keyword">
        <Param Name="value">spinal stabilization</Param>
      </Object>
      <Object Type="keyword">
        <Param Name="value">denosumab</Param>
      </Object>
      <Object Type="keyword">
        <Param Name="value">spondylectomy</Param>
      </Object>
      <Object Type="keyword">
        <Param Name="value">giant cell tumor</Param>
      </Object>
    </ObjectList>
    <ReferenceList/>
  </Article>
  <Article>
    <Journal>
      <PublisherName>Taylor and Francis</PublisherName>
      <JournalTitle>Acta Medica Okayama</JournalTitle>
      <Issn>0169-1864</Issn>
      <Volume>27</Volume>
      <Issue>15</Issue>
      <PubDate PubStatus="ppublish">
        <Year>2013</Year>
        <Month/>
      </PubDate>
    </Journal>
    <ArticleTitle>Positioning device for outdoor mobile robots using optical sensors and lasers</ArticleTitle>
    <FirstPage LZero="delete">1147</FirstPage>
    <LastPage>1160</LastPage>
    <Language>EN</Language>
    <AuthorList>
      <Author>
        <FirstName EmptyYN="N">Isaku</FirstName>
        <LastName>Nagai</LastName>
        <Affiliation/>
      </Author>
      <Author>
        <FirstName EmptyYN="N">Genki</FirstName>
        <LastName>Yamauchi</LastName>
        <Affiliation/>
      </Author>
      <Author>
        <FirstName EmptyYN="N">Keiji</FirstName>
        <LastName>Nagatani</LastName>
        <Affiliation/>
      </Author>
      <Author>
        <FirstName EmptyYN="N">Keigo</FirstName>
        <LastName>Watanabe</LastName>
        <Affiliation/>
      </Author>
      <Author>
        <FirstName EmptyYN="N">Kazuya</FirstName>
        <LastName>Yoshida</LastName>
        <Affiliation/>
      </Author>
    </AuthorList>
    <PublicationType/>
    <ArticleIdList>
      <ArticleId IdType="doi"/>
    </ArticleIdList>
    <Abstract>We propose a novel method for positioning a mobile robot in an outdoor environment using lasers and optical sensors. Position estimation via a noncontact optical method is useful because the information from the wheel odometer and the global positioning system in a mobile robot is unreliable in some situations. Contact optical sensors such as computer mouse are designed to be in contact with a surface and do not function well in strong ambient light conditions. To mitigate the challenges of an outdoor environment, we developed an optical device with a bandpass filter and a pipe to restrict solar light and to detect translation. The use of two devices enables sensing of the mobile robotfs position, including posture. Furthermore, employing a collimated laser beam allows measurements against a surface to be invariable with the distance to the surface. In this paper, we describe motion estimation, device configurations, and several tests for performance evaluation. We also present the experimental positioning results from a vehicle equipped with our optical device on an outdoor path. Finally, we discuss an improvement in postural accuracy by combining an optical device with precise gyroscopes.</Abstract>
    <CoiStatement>No potential conflict of interest relevant to this article was reported.</CoiStatement>
    <ObjectList>
      <Object Type="keyword">
        <Param Name="value">mobile robot</Param>
      </Object>
      <Object Type="keyword">
        <Param Name="value">position estimation</Param>
      </Object>
      <Object Type="keyword">
        <Param Name="value">laser speckle pattern</Param>
      </Object>
      <Object Type="keyword">
        <Param Name="value">optical sensor</Param>
      </Object>
    </ObjectList>
    <ReferenceList/>
  </Article>
  <Article>
    <Journal>
      <PublisherName>IEEE Robotics &amp; Automation Society</PublisherName>
      <JournalTitle>Acta Medica Okayama</JournalTitle>
      <Issn/>
      <Volume/>
      <Issue/>
      <PubDate PubStatus="ppublish">
        <Year>2015</Year>
        <Month/>
      </PubDate>
    </Journal>
    <ArticleTitle>Path Tracking by a Mobile Robot Equipped with Only a Downward Facing Camera</ArticleTitle>
    <FirstPage LZero="delete">6053</FirstPage>
    <LastPage>6058</LastPage>
    <Language>EN</Language>
    <AuthorList>
      <Author>
        <FirstName EmptyYN="N">Isaku</FirstName>
        <LastName>Nagai</LastName>
        <Affiliation/>
      </Author>
      <Author>
        <FirstName EmptyYN="N">Keigo</FirstName>
        <LastName>Watanabe</LastName>
        <Affiliation/>
      </Author>
    </AuthorList>
    <PublicationType/>
    <ArticleIdList>
      <ArticleId IdType="doi"/>
    </ArticleIdList>
    <Abstract>This paper presents a practical path-tracking
method for a mobile robot with only a downward camera facing the passage plane. A unique algorithm for tracking and searching ground images with natural texture is used to localize the robot without a feature-point extraction scheme commonly used in other visual odometry methods. In our tracking algorithm, groups of reference pixels are used to detect the relative translation and rotation between frames. Furthermore, a reference pixel group of another shape is registered both to record a path and to correct errors accumulated during localization. All image processing and robot control operations are carried out with low memory consumption for image registration and fast calculation times for completing the searches on a laptop PC. We also describe experimental results in which a vehicle developed by the proposed method repeatedly performed precise path tracking under indoor and outdoor environments.</Abstract>
    <CoiStatement>No potential conflict of interest relevant to this article was reported.</CoiStatement>
    <ObjectList/>
    <ReferenceList/>
  </Article>
</ArticleSet>
