
| ID | 70184 |
| フルテキストURL | |
| 著者 |
Hirata, Yuichi
Department of Neurological Surgery, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Sciences
Hiramatsu, Masafumi
Department of Neurological Surgery, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Sciences
Sugiu, Kenji
Department of Neurological Surgery, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Sciences
ORCID
Kaken ID
publons
researchmap
Baba, Fukiko
Department of Neurological Surgery, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Sciences
Fujita, Juntaro
Department of Neurological Surgery, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Sciences
Sotome, Yuta
Department of Neurological Surgery, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Sciences
Kawakami, Masato
Department of Neurological Surgery, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Sciences
Kimura, Ryu
Department of Neurological Surgery, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Sciences
Ebisudani, Yuki
Department of Neurological Surgery, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Sciences
Haruma, Jun
Department of Neurological Surgery, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Sciences
ORCID
Kaken ID
researchmap
Hishikawa, Tomohito
Department of Neurosurgery, Kawasaki Medical School
Kaken ID
publons
researchmap
Tanaka, Shota
Department of Neurological Surgery, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Sciences
|
| 抄録 | Background: In recent years, the effectiveness of flow diverters (FDs) for the treatment of intracranial aneurysms has been reported. While FDs are effective, their deployment involves advancing a delivery wire distally, which may pose a risk if a distal aneurysm exists within the same artery. In such cases, the delivery wire could potentially perforate the distal aneurysm. Here, we present two cases of tandem aneurysms in which an internal carotid artery (ICA) aneurysm was treated with an FD following the treatment of a distal cerebral aneurysm.
Case description: A 44-year-old woman and a 67-year-old woman underwent magnetic resonance imaging for headache or abducens nerve palsy. In both cases, two aneurysms were revealed: one at the ICA and the other either at the middle cerebral artery or the top of the ICA. Due to the risk of perforation by the delivery wire during FD deployment, the distal aneurysms were treated first—either with surgical neck clipping or stent-assisted coil embolization. One month after the initial treatment, FD placement for the ICA aneurysm was performed as planned without complications in either case. Discussion: This is the first report where tandem aneurysms were successfully treated with treatment for distal cerebral aneurysms, followed by FDs for proximal ICA aneurysms. We emphasize the potential risk of perforation of the distal aneurysm by the delivery wire during FD placement. Conclusion: Treatment of distal cerebral aneurysms beforehand can help ensure the safe and effective use of FDs in patients with tandem aneurysms. |
| キーワード | Flow diverter
Tandem aneurysms
Complication
Perforation
Delivery wire
|
| 発行日 | 2025-10
|
| 出版物タイトル |
World Neurosurgery: X
|
| 巻 | 28巻
|
| 出版者 | Elsevier BV
|
| 開始ページ | 100540
|
| ISSN | 2590-1397
|
| 資料タイプ |
学術雑誌論文
|
| 言語 |
英語
|
| OAI-PMH Set |
岡山大学
|
| 著作権者 | © 2025 The Authors.
|
| 論文のバージョン | publisher
|
| DOI | |
| Web of Science KeyUT | |
| 関連URL | isVersionOf https://doi.org/10.1016/j.wnsx.2025.100540
|
| ライセンス | http://creativecommons.org/licenses/by-nc-nd/4.0/
|