<?xml version="1.0" encoding="Windows-31J"?>
<ArticleSet xmlns="http://www.openarchives.org/OAI/2.0/">
  <Article>
    <Journal>
      <PublisherName>IOP Publishing</PublisherName>
      <JournalTitle>Acta Medica Okayama</JournalTitle>
      <Issn>0021-4922</Issn>
      <Volume>65</Volume>
      <Issue>7</Issue>
      <PubDate PubStatus="ppublish">
        <Year>2026</Year>
        <Month/>
      </PubDate>
    </Journal>
    <ArticleTitle>Study of preload mechanism for small piezoelectric transducers with hollow structure for cryogenic environments</ArticleTitle>
    <FirstPage LZero="delete">07SP13</FirstPage>
    <LastPage/>
    <Language>EN</Language>
    <AuthorList>
      <Author>
        <FirstName EmptyYN="N">Souta</FirstName>
        <LastName>Mimura</LastName>
        <Affiliation>Graduate School of Environment, Life, Natural Science and Technology, Okayama University</Affiliation>
      </Author>
      <Author>
        <FirstName EmptyYN="N">Takefumi</FirstName>
        <LastName>Kanda</LastName>
        <Affiliation>Graduate School of Environment, Life, Natural Science and Technology, Okayama University</Affiliation>
      </Author>
      <Author>
        <FirstName EmptyYN="N">Daisuke</FirstName>
        <LastName>Yamaguchi</LastName>
        <Affiliation>Graduate School of Environment, Life, Natural Science and Technology, Okayama University</Affiliation>
      </Author>
      <Author>
        <FirstName EmptyYN="N">Kazuki</FirstName>
        <LastName>Kubo</LastName>
        <Affiliation>Graduate School of Environment, Life, Natural Science and Technology, Okayama University</Affiliation>
      </Author>
      <Author>
        <FirstName EmptyYN="N">Shuichi</FirstName>
        <LastName>Wakimoto</LastName>
        <Affiliation>Graduate School of Environment, Life, Natural Science and Technology, Okayama University</Affiliation>
      </Author>
    </AuthorList>
    <PublicationType/>
    <ArticleIdList>
      <ArticleId IdType="doi"/>
    </ArticleIdList>
    <Abstract>In various industrial fields, cryogenic fluids such as liquid hydrogen and liquid nitrogen are increasingly used as fuels and refrigerants. To control the flow rate of those fluids, valves that can be operated in cryogenic environments are needed. In general, the miniaturization of the valve can be achieved by using a piezoelectric ceramic as an actuator to drive the mechanism. Additionally, the properties degradation can be suppressed by applying a preload to the piezoelectric ceramic. To miniaturize the piezoelectric actuator applying preload at low temperature conditions, we use differences in thermal expansion coefficients to apply preload to the piezoelectric ceramics. In this study, we have designed and fabricated a small piezoelectric transducer with a hollow structure for cryogenic environments by using this proposed structure. To evaluate the fabricated transducer, we have measured vibration velocity and estimated the acceleration in cryogenic environments.</Abstract>
    <CoiStatement>No potential conflict of interest relevant to this article was reported.</CoiStatement>
    <ObjectList/>
    <ReferenceList/>
  </Article>
  <Article>
    <Journal>
      <PublisherName>Elsevier BV</PublisherName>
      <JournalTitle>Acta Medica Okayama</JournalTitle>
      <Issn>0924-4247</Issn>
      <Volume>408</Volume>
      <Issue/>
      <PubDate PubStatus="ppublish">
        <Year>2026</Year>
        <Month/>
      </PubDate>
    </Journal>
    <ArticleTitle>A flexible PVDF-based galloping flow sensor</ArticleTitle>
    <FirstPage LZero="delete">117978</FirstPage>
    <LastPage/>
    <Language>EN</Language>
    <AuthorList>
      <Author>
        <FirstName EmptyYN="N">Mitsuki</FirstName>
        <LastName>Kurose</LastName>
        <Affiliation>Graduate School of Environmental, Life, Natural Science and Technology, Okayama University</Affiliation>
      </Author>
      <Author>
        <FirstName EmptyYN="N">Takefumi</FirstName>
        <LastName>Kanda</LastName>
        <Affiliation>Graduate School of Environmental, Life, Natural Science and Technology, Okayama University</Affiliation>
      </Author>
      <Author>
        <FirstName EmptyYN="N">Yuya</FirstName>
        <LastName>Sato</LastName>
        <Affiliation>Graduate School of Environmental, Life, Natural Science and Technology, Okayama University</Affiliation>
      </Author>
      <Author>
        <FirstName EmptyYN="N">Shuichi</FirstName>
        <LastName>Wakimoto</LastName>
        <Affiliation>Graduate School of Environmental, Life, Natural Science and Technology, Okayama University</Affiliation>
      </Author>
      <Author>
        <FirstName EmptyYN="N">Daisuke</FirstName>
        <LastName>Yamaguchi</LastName>
        <Affiliation>Graduate School of Environmental, Life, Natural Science and Technology, Okayama University</Affiliation>
      </Author>
      <Author>
        <FirstName EmptyYN="N">Shinji</FirstName>
        <LastName>Hiejima</LastName>
        <Affiliation>Graduate School of Environmental, Life, Natural Science and Technology, Okayama University</Affiliation>
      </Author>
      <Author>
        <FirstName EmptyYN="N">Takeji</FirstName>
        <LastName>Ueda</LastName>
        <Affiliation>Hydro-VENUS Co., Ltd., Okayama University</Affiliation>
      </Author>
    </AuthorList>
    <PublicationType/>
    <ArticleIdList>
      <ArticleId IdType="doi"/>
    </ArticleIdList>
    <Abstract>Effective monitoring of low flow velocities in small rivers and irrigation channels is hindered by the power requirements and maintenance costs of existing technologies. This study proposes a novel flexible piezoelectric polymer flow sensor utilizing galloping vibration to detect flow velocity in the low range (&#8804;  0.1&#8201;m/s). The sensor features a flexible cantilever structure composed of a silicone rubber beam embedded with a polyvinylidene fluoride (PVDF) film and a tip pillar. Unlike conventional devices based on flow-induced vibration, the use of low-stiffness materials enables the induction of self-excited vibration even under weak fluid forces. Computational fluid dynamics (CFD) analysis has been conducted to optimize the tip shape; a D-shaped semicylinder is selected over a cylinder and a square prism because the geometry maximizes the lift force per unit mass, ensuring efficient energy conversion. To predict sensor behavior, a coupled mechanical-fluid-electrical model was developed. Specifically, the model accounts for the static deflection angle caused by fluid drag. Water channel experiments demonstrated that sensors with beam thicknesses under 4&#8201;mm successfully generated stable periodic outputs at 0.1&#8201;m/s, a regime previously difficult for galloping-based devices. Conversely, thicker beam which has a thickness of 8&#8201;mm achieved higher outputs at higher velocities but failed to actuate at low speeds. Furthermore, the study showed a vibration suppression phenomenon in flexible beams at high flow velocities due to excessive static deflection, which was accurately reproduced by the analytical model. These findings establish structural stiffness as the critical design parameter for optimizing the operable velocity range of flow sensors.</Abstract>
    <CoiStatement>No potential conflict of interest relevant to this article was reported.</CoiStatement>
    <ObjectList>
      <Object Type="keyword">
        <Param Name="value">Flow velocity sensor</Param>
      </Object>
      <Object Type="keyword">
        <Param Name="value">Piezoelectric polymer</Param>
      </Object>
      <Object Type="keyword">
        <Param Name="value">Flow induced vibration</Param>
      </Object>
      <Object Type="keyword">
        <Param Name="value">Galloping vibration</Param>
      </Object>
    </ObjectList>
    <ReferenceList/>
  </Article>
  <Article>
    <Journal>
      <PublisherName>Elsevier BV</PublisherName>
      <JournalTitle>Acta Medica Okayama</JournalTitle>
      <Issn>0924-4247</Issn>
      <Volume>408</Volume>
      <Issue/>
      <PubDate PubStatus="ppublish">
        <Year>2026</Year>
        <Month/>
      </PubDate>
    </Journal>
    <ArticleTitle>Tip position estimation of a 3-DOF soft mechanism using artificial muscles with optical fibers</ArticleTitle>
    <FirstPage LZero="delete">117938</FirstPage>
    <LastPage/>
    <Language>EN</Language>
    <AuthorList>
      <Author>
        <FirstName EmptyYN="N">Rikimaru</FirstName>
        <LastName>Okada</LastName>
        <Affiliation>Graduate School of Environment, Life, Natural Science and Technology, Okayama University</Affiliation>
      </Author>
      <Author>
        <FirstName EmptyYN="N">Shuichi</FirstName>
        <LastName>Wakimoto</LastName>
        <Affiliation>Graduate School of Environment, Life, Natural Science and Technology, Okayama University</Affiliation>
      </Author>
      <Author>
        <FirstName EmptyYN="N">Yuichiro</FirstName>
        <LastName>Toda</LastName>
        <Affiliation>Graduate School of Environment, Life, Natural Science and Technology, Okayama University</Affiliation>
      </Author>
      <Author>
        <FirstName EmptyYN="N">Shun</FirstName>
        <LastName>Miura</LastName>
        <Affiliation>Graduate School of Environment, Life, Natural Science and Technology, Okayama University</Affiliation>
      </Author>
      <Author>
        <FirstName EmptyYN="N">Daisuke</FirstName>
        <LastName>Yamaguchi</LastName>
        <Affiliation>Graduate School of Environment, Life, Natural Science and Technology, Okayama University</Affiliation>
      </Author>
      <Author>
        <FirstName EmptyYN="N">Takefumi</FirstName>
        <LastName>Kanda</LastName>
        <Affiliation>Graduate School of Environment, Life, Natural Science and Technology, Okayama University</Affiliation>
      </Author>
    </AuthorList>
    <PublicationType/>
    <ArticleIdList>
      <ArticleId IdType="doi"/>
    </ArticleIdList>
    <Abstract>McKibben-type pneumatic artificial muscles (PAMs) are lightweight and flexible soft actuators with a high power-to-weight ratio, and have been widely applied to rehabilitation devices, power-assist systems, and soft robotic mechanisms. By integrating sensing functions into PAMs, their usability and controllability can be enhanced, enabling the development of more practical and advanced soft mechanisms. We previously proposed a smart artificial muscle (SAM) by integrating an optical fiber into the braided sleeve of a McKibben-type PAM, which enables displacement estimation by measuring optical bending loss. The SAM is compatible with conventional PAM fabrication processes; however, the sensor output exhibits strong nonlinearity and time dependency. In this study, an LSTM-based state estimation framework is extended from a single SAM to a three-degree-of-freedom soft mechanism composed of multiple SAMs, where strong nonlinear coupling and mutual interference arise among actuators. In the proposed framework, the LSTM model jointly processes time-series data of multi-channel optical sensor outputs and applied pressures of the three SAMs, along with past estimated states as inputs. This structure enables the model to capture nonlinear coupling, hysteresis, and time-dependent behavior, allowing estimation of the tip position of the soft mechanism. Experimental results demonstrate that the proposed method accurately captures complex nonlinear dynamics and mutual mechanical interference among multiple SAMs, achieving accurate tip position estimation. These results indicate that SAMs with integrated sensing and actuation capabilities, combined with machine-learning-based estimation, provide an effective approach for state estimation of multi-DOF soft robotic mechanisms.</Abstract>
    <CoiStatement>No potential conflict of interest relevant to this article was reported.</CoiStatement>
    <ObjectList>
      <Object Type="keyword">
        <Param Name="value">Pneumatic artificial muscle</Param>
      </Object>
      <Object Type="keyword">
        <Param Name="value">Smart artificial muscle</Param>
      </Object>
      <Object Type="keyword">
        <Param Name="value">Soft mechanism</Param>
      </Object>
      <Object Type="keyword">
        <Param Name="value">State estimation</Param>
      </Object>
      <Object Type="keyword">
        <Param Name="value">Long short-term memory</Param>
      </Object>
    </ObjectList>
    <ReferenceList/>
  </Article>
  <Article>
    <Journal>
      <PublisherName>MDPI</PublisherName>
      <JournalTitle>Acta Medica Okayama</JournalTitle>
      <Issn>1424-8220</Issn>
      <Volume>25</Volume>
      <Issue>7</Issue>
      <PubDate PubStatus="ppublish">
        <Year>2025</Year>
        <Month/>
      </PubDate>
    </Journal>
    <ArticleTitle>Length Estimation of Pneumatic Artificial Muscle with Optical Fiber Sensor Using Machine Learning</ArticleTitle>
    <FirstPage LZero="delete">2221</FirstPage>
    <LastPage/>
    <Language>EN</Language>
    <AuthorList>
      <Author>
        <FirstName EmptyYN="N">Yilei</FirstName>
        <LastName>Ni</LastName>
        <Affiliation>Graduate School of Environmental, Life, Natural Science and Technology, Okayama University</Affiliation>
      </Author>
      <Author>
        <FirstName EmptyYN="N">Shuichi</FirstName>
        <LastName>Wakimoto</LastName>
        <Affiliation>Graduate School of Environmental, Life, Natural Science and Technology, Okayama University</Affiliation>
      </Author>
      <Author>
        <FirstName EmptyYN="N">Weihang</FirstName>
        <LastName>Tian</LastName>
        <Affiliation>Graduate School of Environmental, Life, Natural Science and Technology, Okayama University</Affiliation>
      </Author>
      <Author>
        <FirstName EmptyYN="N">Yuichiro</FirstName>
        <LastName>Toda</LastName>
        <Affiliation>Graduate School of Environmental, Life, Natural Science and Technology, Okayama University</Affiliation>
      </Author>
      <Author>
        <FirstName EmptyYN="N">Takefumi</FirstName>
        <LastName>Kanda</LastName>
        <Affiliation>Graduate School of Environmental, Life, Natural Science and Technology, Okayama University</Affiliation>
      </Author>
      <Author>
        <FirstName EmptyYN="N">Daisuke</FirstName>
        <LastName>Yamaguchi</LastName>
        <Affiliation>Graduate School of Environmental, Life, Natural Science and Technology, Okayama University</Affiliation>
      </Author>
    </AuthorList>
    <PublicationType/>
    <ArticleIdList>
      <ArticleId IdType="doi"/>
    </ArticleIdList>
    <Abstract>A McKibben artificial muscle is a soft actuator driven by air pressure, characterized by its flexibility, lightweight design, and high power-to-weight ratio. We have developed a smart artificial muscle that is capable of sensing its motion. To enable this sensing function, an optical fiber was integrated into the sleeve consisting of multiple fibers and serving as a component of the McKibben artificial muscle. By measuring the macrobending loss of the optical fiber, the length of the smart artificial muscle is expected to be estimated. However, experimental results indicated that the sensor's characteristics depend not only on the length but also on the load and the applied air pressure. This dependency arises because the stress applied to the optical fiber increases, causing microbending loss. In this study, we employed a machine learning model, primarily composed of Long Short-Term Memory (LSTM) neural networks, to estimate the length of the smart artificial muscle. The experimental results demonstrate that the length estimation obtained through machine learning exhibits a smaller error. This suggests that machine learning is a feasible approach to enhancing the length measurement accuracy of the smart artificial muscle.</Abstract>
    <CoiStatement>No potential conflict of interest relevant to this article was reported.</CoiStatement>
    <ObjectList>
      <Object Type="keyword">
        <Param Name="value">McKibben artificial muscle</Param>
      </Object>
      <Object Type="keyword">
        <Param Name="value">machine learning</Param>
      </Object>
      <Object Type="keyword">
        <Param Name="value">optical fiber</Param>
      </Object>
      <Object Type="keyword">
        <Param Name="value">motion estimation</Param>
      </Object>
    </ObjectList>
    <ReferenceList/>
  </Article>
  <Article>
    <Journal>
      <PublisherName>MDPI</PublisherName>
      <JournalTitle>Acta Medica Okayama</JournalTitle>
      <Issn>2076-0825</Issn>
      <Volume>13</Volume>
      <Issue>3</Issue>
      <PubDate PubStatus="ppublish">
        <Year>2024</Year>
        <Month/>
      </PubDate>
    </Journal>
    <ArticleTitle>A Microchannel Device for Droplet Classification by Manipulation Using Piezoelectric Vibrator</ArticleTitle>
    <FirstPage LZero="delete">95</FirstPage>
    <LastPage/>
    <Language>EN</Language>
    <AuthorList>
      <Author>
        <FirstName EmptyYN="N">Ao</FirstName>
        <LastName>Fujioka</LastName>
        <Affiliation>Graduate School of Natural Science and Technology, Okayama University</Affiliation>
      </Author>
      <Author>
        <FirstName EmptyYN="N">Shoko</FirstName>
        <LastName>Seo</LastName>
        <Affiliation>Graduate School of Natural Science and Technology, Okayama University</Affiliation>
      </Author>
      <Author>
        <FirstName EmptyYN="N">Takefumi</FirstName>
        <LastName>Kanda</LastName>
        <Affiliation>Graduate School of Natural Science and Technology, Okayama University</Affiliation>
      </Author>
      <Author>
        <FirstName EmptyYN="N">Shuichi</FirstName>
        <LastName>Wakimoto</LastName>
        <Affiliation>Graduate School of Natural Science and Technology, Okayama University</Affiliation>
      </Author>
      <Author>
        <FirstName EmptyYN="N">Daisuke</FirstName>
        <LastName>Yamaguchi</LastName>
        <Affiliation>Graduate School of Natural Science and Technology, Okayama University</Affiliation>
      </Author>
    </AuthorList>
    <PublicationType/>
    <ArticleIdList>
      <ArticleId IdType="doi"/>
    </ArticleIdList>
    <Abstract>Emulsion formulations should be monodispersed in terms of their stability. Therefore, there is a need for a device that can classify droplets of the desired size from polydispersed emulsions in a fluidized bed manufacturing system. In the previous study, we evaluated the fabrication of a droplet manipulation device using acoustic radiation forces through simulation using the finite element method. In this study, particle manipulation experiments using 1, 6, and 10 mu m polystyrene particles were first estimated and evaluated in comparison with their theoretical particle behavior. Based on the results we obtained, the driving conditions and droplet behavior were derived, and the droplet manipulation device using ultrasonic waves to shrink monodisperse emulsions was evaluated. As a result, the droplet classification effect in the microchannel was confirmed to be consistent with the droplet behavior prediction, and the microchannel structure with a constriction component improved its classification effect.</Abstract>
    <CoiStatement>No potential conflict of interest relevant to this article was reported.</CoiStatement>
    <ObjectList>
      <Object Type="keyword">
        <Param Name="value">piezoelectric element</Param>
      </Object>
      <Object Type="keyword">
        <Param Name="value">microchannel</Param>
      </Object>
      <Object Type="keyword">
        <Param Name="value">particle manipulation</Param>
      </Object>
      <Object Type="keyword">
        <Param Name="value">emulsion</Param>
      </Object>
      <Object Type="keyword">
        <Param Name="value">droplet</Param>
      </Object>
    </ObjectList>
    <ReferenceList/>
  </Article>
  <Article>
    <Journal>
      <PublisherName>IOP Publishing</PublisherName>
      <JournalTitle>Acta Medica Okayama</JournalTitle>
      <Issn>0021-4922</Issn>
      <Volume>63</Volume>
      <Issue>3</Issue>
      <PubDate PubStatus="ppublish">
        <Year>2024</Year>
        <Month/>
      </PubDate>
    </Journal>
    <ArticleTitle>Evaluation of transducer for cryogenic actuators by equivalent circuit model</ArticleTitle>
    <FirstPage LZero="delete">03SP03</FirstPage>
    <LastPage/>
    <Language>EN</Language>
    <AuthorList>
      <Author>
        <FirstName EmptyYN="N">Kazuki</FirstName>
        <LastName>Kubo</LastName>
        <Affiliation>Graduate School of Environment, Life, Natural, Science and Technology, Okayama University</Affiliation>
      </Author>
      <Author>
        <FirstName EmptyYN="N">Kairi</FirstName>
        <LastName>Yagi</LastName>
        <Affiliation>Graduate School of Environment, Life, Natural, Science and Technology, Okayama University</Affiliation>
      </Author>
      <Author>
        <FirstName EmptyYN="N">Takefumi</FirstName>
        <LastName>Kanda</LastName>
        <Affiliation>Graduate School of Environment, Life, Natural, Science and Technology, Okayama University</Affiliation>
      </Author>
      <Author>
        <FirstName EmptyYN="N">Koa</FirstName>
        <LastName>Yasuda</LastName>
        <Affiliation>Graduate School of Environment, Life, Natural, Science and Technology, Okayama University</Affiliation>
      </Author>
      <Author>
        <FirstName EmptyYN="N">Daisuke</FirstName>
        <LastName>Yamaguchi</LastName>
        <Affiliation>Graduate School of Environment, Life, Natural, Science and Technology, Okayama University</Affiliation>
      </Author>
      <Author>
        <FirstName EmptyYN="N">Shuichi</FirstName>
        <LastName>Wakimoto</LastName>
        <Affiliation>Graduate School of Environment, Life, Natural, Science and Technology, Okayama University</Affiliation>
      </Author>
    </AuthorList>
    <PublicationType/>
    <ArticleIdList>
      <ArticleId IdType="doi"/>
    </ArticleIdList>
    <Abstract>Cryogenic environments are increasingly used in scientific and industrial fields. Recently, cryogenic environments are also used for storage and supply of liquid hydrogen, which is considered essential for the realization of a decarbonized society. Actuators to drive a valve that controls such a low-temperature fluid are required. In this study, a piezoelectric transducer that can be driven in the cryogenic environment has been fabricated and evaluated. Although the performance of piezoelectric elements degrades at cryogenic temperatures in general, the application of a preload can suppress the degradation of performance. Equivalent circuits were used for evaluation, and force factors and figures of merit were compared. As a result, the force factor was as high as that at RT even at cryogenic temperatures, and a high figure of merit was obtained. The result indicates that the transducer can be used for the driving of micro actuator at cryogenic temperature.</Abstract>
    <CoiStatement>No potential conflict of interest relevant to this article was reported.</CoiStatement>
    <ObjectList>
      <Object Type="keyword">
        <Param Name="value">cryogenic</Param>
      </Object>
      <Object Type="keyword">
        <Param Name="value">ultrasonic</Param>
      </Object>
      <Object Type="keyword">
        <Param Name="value">piezoelectric</Param>
      </Object>
      <Object Type="keyword">
        <Param Name="value">transducer</Param>
      </Object>
    </ObjectList>
    <ReferenceList/>
  </Article>
  <Article>
    <Journal>
      <PublisherName>MDPI</PublisherName>
      <JournalTitle>Acta Medica Okayama</JournalTitle>
      <Issn>1424-8220</Issn>
      <Volume>22</Volume>
      <Issue>9</Issue>
      <PubDate PubStatus="ppublish">
        <Year>2022</Year>
        <Month/>
      </PubDate>
    </Journal>
    <ArticleTitle>Displacement Sensing of an Active String Actuator Using a Step-Index Multimode Optical Fiber Sensor</ArticleTitle>
    <FirstPage LZero="delete">3232</FirstPage>
    <LastPage/>
    <Language>EN</Language>
    <AuthorList>
      <Author>
        <FirstName EmptyYN="N">Weihang</FirstName>
        <LastName>Tian</LastName>
        <Affiliation>Graduate School of Natural Science and Technology, Okayama University</Affiliation>
      </Author>
      <Author>
        <FirstName EmptyYN="N">Shuichi</FirstName>
        <LastName>Wakimoto</LastName>
        <Affiliation>Graduate School of Natural Science and Technology, Okayama University</Affiliation>
      </Author>
      <Author>
        <FirstName EmptyYN="N">Takefumi</FirstName>
        <LastName>Kanda</LastName>
        <Affiliation>Graduate School of Natural Science and Technology, Okayama University</Affiliation>
      </Author>
      <Author>
        <FirstName EmptyYN="N">Daisuke</FirstName>
        <LastName>Yamaguchi</LastName>
        <Affiliation>Graduate School of Natural Science and Technology, Okayama University</Affiliation>
      </Author>
    </AuthorList>
    <PublicationType/>
    <ArticleIdList>
      <ArticleId IdType="doi"/>
    </ArticleIdList>
    <Abstract>A thin McKibben artificial muscle is a pneumatic actuator with an outer diameter of only 1.8 mm. We fabricated a string-shaped actuator called an "active string actuator," which achieves a high contractile displacement by accumulating thin McKibben artificial muscles. To control the displacement, the length of the active string actuator should be estimated. However, this is difficult because bulky and rigid sensors are unsuitable for the sensor element of the active string actuator. Therefore, in this study, we propose a new sensing method for estimating the length of an active string actuator. The proposed sensing system is simple and comprises only three components: a step-index multimode optical fiber, a light emitter, and a light receiver. A step-index multimode optical fiber was combined with the active string actuator, and the length was estimated from the change in the amount of light propagating in the optical fiber when the active string actuator was driven. Fundamental experiments were conducted in this study, and the results demonstrated that the optical fiber sensor value changed with the actuator length. This suggests that it is possible to estimate the displacement of an active string actuator using an optical fiber sensor.</Abstract>
    <CoiStatement>No potential conflict of interest relevant to this article was reported.</CoiStatement>
    <ObjectList>
      <Object Type="keyword">
        <Param Name="value">thin artificial muscle</Param>
      </Object>
      <Object Type="keyword">
        <Param Name="value">active string actuator</Param>
      </Object>
      <Object Type="keyword">
        <Param Name="value">step-index multimode optical fiber</Param>
      </Object>
      <Object Type="keyword">
        <Param Name="value">displacement sensing</Param>
      </Object>
    </ObjectList>
    <ReferenceList/>
  </Article>
  <Article>
    <Journal>
      <PublisherName>MDPI</PublisherName>
      <JournalTitle>Acta Medica Okayama</JournalTitle>
      <Issn>2076-0825</Issn>
      <Volume>10</Volume>
      <Issue>3</Issue>
      <PubDate PubStatus="ppublish">
        <Year>2021</Year>
        <Month/>
      </PubDate>
    </Journal>
    <ArticleTitle>Core-Shell Droplet Generation Device Using a Flexural Bolt-Clamped Langevin-Type Ultrasonic Transducer</ArticleTitle>
    <FirstPage LZero="delete">55</FirstPage>
    <LastPage/>
    <Language>EN</Language>
    <AuthorList>
      <Author>
        <FirstName EmptyYN="N">Kentaro</FirstName>
        <LastName>Omori</LastName>
        <Affiliation>Graduate School of Natural Science and Technology, Okayama University</Affiliation>
      </Author>
      <Author>
        <FirstName EmptyYN="N">Nozomu</FirstName>
        <LastName>Fujimoto</LastName>
        <Affiliation>Graduate School of Natural Science and Technology, Okayama University</Affiliation>
      </Author>
      <Author>
        <FirstName EmptyYN="N">Takefumi</FirstName>
        <LastName>Kanda</LastName>
        <Affiliation>Graduate School of Natural Science and Technology, Okayama University</Affiliation>
      </Author>
      <Author>
        <FirstName EmptyYN="N">Shuichi</FirstName>
        <LastName>Wakimoto</LastName>
        <Affiliation>Graduate School of Natural Science and Technology, Okayama University</Affiliation>
      </Author>
      <Author>
        <FirstName EmptyYN="N">Norihisa</FirstName>
        <LastName>Seno</LastName>
        <Affiliation>Graduate School of Natural Science and Technology, Okayama University</Affiliation>
      </Author>
    </AuthorList>
    <PublicationType/>
    <ArticleIdList>
      <ArticleId IdType="doi"/>
    </ArticleIdList>
    <Abstract>Droplets with a core-shell structure formed from two immiscible liquids are used in various industrial field owing to their useful physical and chemical characteristics. Efficient generation of uniform core-shell droplets plays an important role in terms of productivity. In this study, monodisperse core-shell droplets were efficiently generated using a flexural bolt-clamped Langevin-type transducer and two micropore plates. Water and silicone oil were used as core and shell phases, respectively, to form core-shell droplets in air. When the applied pressure of the core phase, the applied pressure of the shell phase, and the vibration velocity in the micropore were 200 kPa, 150 kPa, and 8.2 mm/s, respectively, the average diameter and coefficient of variation of the droplets were 207.7 mu m and 1.6%, respectively. A production rate of 29,000 core-shell droplets per second was achieved. This result shows that the developed device is effective for generating monodisperse core-shell droplets.</Abstract>
    <CoiStatement>No potential conflict of interest relevant to this article was reported.</CoiStatement>
    <ObjectList>
      <Object Type="keyword">
        <Param Name="value">core-shell droplet</Param>
      </Object>
      <Object Type="keyword">
        <Param Name="value">microfluidic device</Param>
      </Object>
      <Object Type="keyword">
        <Param Name="value">ultrasonic transducer</Param>
      </Object>
    </ObjectList>
    <ReferenceList/>
  </Article>
  <Article>
    <Journal>
      <PublisherName>Elsevier</PublisherName>
      <JournalTitle>Acta Medica Okayama</JournalTitle>
      <Issn>0924-4247</Issn>
      <Volume>164</Volume>
      <Issue>1-2</Issue>
      <PubDate PubStatus="ppublish">
        <Year>2010</Year>
        <Month/>
      </PubDate>
    </Journal>
    <ArticleTitle>Multiplex pneumatic control method for multi-drive system</ArticleTitle>
    <FirstPage LZero="delete">88</FirstPage>
    <LastPage>94</LastPage>
    <Language>EN</Language>
    <AuthorList>
      <Author>
        <FirstName EmptyYN="N">Yasutaka</FirstName>
        <LastName>Nishioka</LastName>
        <Affiliation/>
      </Author>
      <Author>
        <FirstName EmptyYN="N">Koichi</FirstName>
        <LastName>Suzumori</LastName>
        <Affiliation/>
      </Author>
      <Author>
        <FirstName EmptyYN="N">Takefumi</FirstName>
        <LastName>Kanda</LastName>
        <Affiliation/>
      </Author>
      <Author>
        <FirstName EmptyYN="N">Shuichi</FirstName>
        <LastName>Wakimoto</LastName>
        <Affiliation/>
      </Author>
    </AuthorList>
    <PublicationType/>
    <ArticleIdList>
      <ArticleId IdType="doi"/>
    </ArticleIdList>
    <Abstract>Pneumatic actuators have several advantages such as light weight safety low cost and high compliance However many pneumatic actuators have complicated systems that include a compressor air tubes and pneumatic valves with electrical wires This research proposes a new control method for a multiplex pneumatic transmission constructed with special resonant valves and air tubes with a control system driven by air vibration in air tubes without electrical wires The control is simplified and effective for pneumatic systems having many degrees of freedom In this paper the development of a primitive model of the resonant valve and a prototype valve is described In addition two control methods which are a superimposing method and a time-sharing method are shown and the independent driving of four actuators is realized by using one of the control methods with air tubes only.</Abstract>
    <CoiStatement>No potential conflict of interest relevant to this article was reported.</CoiStatement>
    <ObjectList>
      <Object Type="keyword">
        <Param Name="value">Pneumatic</Param>
      </Object>
      <Object Type="keyword">
        <Param Name="value">Valve</Param>
      </Object>
      <Object Type="keyword">
        <Param Name="value">Actuator</Param>
      </Object>
      <Object Type="keyword">
        <Param Name="value">Multi-DOF</Param>
      </Object>
      <Object Type="keyword">
        <Param Name="value">Resonant</Param>
      </Object>
      <Object Type="keyword">
        <Param Name="value">Mechatronics</Param>
      </Object>
    </ObjectList>
    <ReferenceList/>
  </Article>
  <Article>
    <Journal>
      <PublisherName>IOP Publishing</PublisherName>
      <JournalTitle>Acta Medica Okayama</JournalTitle>
      <Issn>0964-1726</Issn>
      <Volume>20</Volume>
      <Issue>10</Issue>
      <PubDate PubStatus="ppublish">
        <Year>2011</Year>
        <Month/>
      </PubDate>
    </Journal>
    <ArticleTitle>Design of a variable-stiffness robotic hand using pneumatic soft rubber actuators</ArticleTitle>
    <FirstPage LZero="delete"/>
    <LastPage/>
    <Language>EN</Language>
    <AuthorList>
      <Author>
        <FirstName EmptyYN="N">Jun-ya</FirstName>
        <LastName>Nagase</LastName>
        <Affiliation/>
      </Author>
      <Author>
        <FirstName EmptyYN="N">Shuichi</FirstName>
        <LastName>Wakimoto</LastName>
        <Affiliation/>
      </Author>
      <Author>
        <FirstName EmptyYN="N">Toshiyuki</FirstName>
        <LastName>Satoh</LastName>
        <Affiliation/>
      </Author>
      <Author>
        <FirstName EmptyYN="N">Norihiko</FirstName>
        <LastName>Saga</LastName>
        <Affiliation/>
      </Author>
      <Author>
        <FirstName EmptyYN="N">Koichi</FirstName>
        <LastName>Suzumori</LastName>
        <Affiliation/>
      </Author>
    </AuthorList>
    <PublicationType/>
    <ArticleIdList>
      <ArticleId IdType="doi"/>
    </ArticleIdList>
    <Abstract>In recent years, Japanese society has been ageing, engendering a labor shortage of young workers. Robots are therefore expected to be useful in performing tasks such as day-to-day support for elderly people. In particular, robots that are intended for use in the field of medical care and welfare are expected to be safe when operating in a human environment because they often come into contact with people. Furthermore, robots must perform various tasks such as regrasping, grasping of soft objects, and tasks using frictional force. Given these demands and circumstances, a tendon-driven robot hand with a stiffness changing finger has been developed. The finger surface stiffness can be altered by adjusting the input pressure depending on the task. Additionally, the coefficient of static friction can be altered by changing the surface stiffness merely by adjusting the input air pressure. This report describes the basic structure, driving mechanism, and basic properties of the proposed robot hand.</Abstract>
    <CoiStatement>No potential conflict of interest relevant to this article was reported.</CoiStatement>
    <ObjectList/>
    <ReferenceList/>
  </Article>
  <Article>
    <Journal>
      <PublisherName>日本設計工学会</PublisherName>
      <JournalTitle>Acta Medica Okayama</JournalTitle>
      <Issn>0919-2948</Issn>
      <Volume>46</Volume>
      <Issue>9</Issue>
      <PubDate PubStatus="ppublish">
        <Year>2011</Year>
        <Month/>
      </PubDate>
    </Journal>
    <ArticleTitle>空気圧剛性可変フィンガを有するバルーン型腱駆動ロボットハンドの開発</ArticleTitle>
    <FirstPage LZero="delete">517</FirstPage>
    <LastPage>523</LastPage>
    <Language>EN</Language>
    <AuthorList>
      <Author>
        <FirstName EmptyYN="N">Jun-ya</FirstName>
        <LastName>Nagase</LastName>
        <Affiliation/>
      </Author>
      <Author>
        <FirstName EmptyYN="N">Shuichi</FirstName>
        <LastName>Wakimoto</LastName>
        <Affiliation/>
      </Author>
      <Author>
        <FirstName EmptyYN="N">Norihiko</FirstName>
        <LastName>Saga</LastName>
        <Affiliation/>
      </Author>
      <Author>
        <FirstName EmptyYN="N">Koichi</FirstName>
        <LastName>Suzumori</LastName>
        <Affiliation/>
      </Author>
    </AuthorList>
    <PublicationType/>
    <ArticleIdList>
      <ArticleId IdType="doi"/>
    </ArticleIdList>
    <Abstract/>
    <CoiStatement>No potential conflict of interest relevant to this article was reported.</CoiStatement>
    <ObjectList>
      <Object Type="keyword">
        <Param Name="value">stiffness change device</Param>
      </Object>
      <Object Type="keyword">
        <Param Name="value">flexible finger</Param>
      </Object>
      <Object Type="keyword">
        <Param Name="value">pneumatic balloon</Param>
      </Object>
      <Object Type="keyword">
        <Param Name="value">robot hand</Param>
      </Object>
      <Object Type="keyword">
        <Param Name="value">tendon-driven</Param>
      </Object>
    </ObjectList>
    <ReferenceList/>
  </Article>
  <Article>
    <Journal>
      <PublisherName>日本ロボット学会</PublisherName>
      <JournalTitle>Acta Medica Okayama</JournalTitle>
      <Issn>0289-1824</Issn>
      <Volume>29</Volume>
      <Issue>7</Issue>
      <PubDate PubStatus="ppublish">
        <Year>2011</Year>
        <Month/>
      </PubDate>
    </Journal>
    <ArticleTitle>大腸内視鏡挿入支援を目指したラバーチューブアクチュエータの設計と基礎駆動特性</ArticleTitle>
    <FirstPage LZero="delete">619</FirstPage>
    <LastPage>625</LastPage>
    <Language>EN</Language>
    <AuthorList>
      <Author>
        <FirstName EmptyYN="N">Shuichi</FirstName>
        <LastName>Wakimoto</LastName>
        <Affiliation/>
      </Author>
      <Author>
        <FirstName EmptyYN="N">Ken</FirstName>
        <LastName>Ozaki</LastName>
        <Affiliation/>
      </Author>
      <Author>
        <FirstName EmptyYN="N">Koichi</FirstName>
        <LastName>Suzumori</LastName>
        <Affiliation/>
      </Author>
    </AuthorList>
    <PublicationType/>
    <ArticleIdList>
      <ArticleId IdType="doi"/>
    </ArticleIdList>
    <Abstract>Colonoscopy is an important medical action to detect disorders like colon cancer. However generally it is difficult to insert a scope into the colon, because the colon is flexible and complex shape. This study aims at development of an actuator which can add propelling ability to a colonoscope. We focus on rubber pneumatic actuators, because advantages of them, for example, high compliance, low cost, water proof, and so on, agree with the required properties of medical devices. In this paper, we design a novel rubber actuator consisting of three air chambers by nonlinear FEM (finite element method) and fabricate the actuator employing the design by extrusion molding method. Basic characteristics of the actuator are clarified by a motion capture system, and functional motion leading assisting colonoscope insertion is observed. Actually using dummy endoscope, transportation ability by the actuators is confirmed experimentally and insertion experiments into a large intestine phantom are conducted.</Abstract>
    <CoiStatement>No potential conflict of interest relevant to this article was reported.</CoiStatement>
    <ObjectList>
      <Object Type="keyword">
        <Param Name="value">Soft Actuator</Param>
      </Object>
      <Object Type="keyword">
        <Param Name="value">Colonoscope Robot</Param>
      </Object>
      <Object Type="keyword">
        <Param Name="value">Soft Mechanism</Param>
      </Object>
    </ObjectList>
    <ReferenceList/>
  </Article>
  <Article>
    <Journal>
      <PublisherName/>
      <JournalTitle>Acta Medica Okayama</JournalTitle>
      <Issn>0169-1864</Issn>
      <Volume>25</Volume>
      <Issue>9-10</Issue>
      <PubDate PubStatus="ppublish">
        <Year>2011</Year>
        <Month/>
      </PubDate>
    </Journal>
    <ArticleTitle>Miniature Pneumatic Curling Rubber Actuator Generating Bidirectional Motion with One Air-Supply Tube</ArticleTitle>
    <FirstPage LZero="delete">1311</FirstPage>
    <LastPage>1330</LastPage>
    <Language>EN</Language>
    <AuthorList>
      <Author>
        <FirstName EmptyYN="N">Shuichi</FirstName>
        <LastName>Wakimoto</LastName>
        <Affiliation/>
      </Author>
      <Author>
        <FirstName EmptyYN="N">Koichi</FirstName>
        <LastName>Suzumori</LastName>
        <Affiliation/>
      </Author>
      <Author>
        <FirstName EmptyYN="N">Keiko</FirstName>
        <LastName>Ogura</LastName>
        <Affiliation/>
      </Author>
    </AuthorList>
    <PublicationType/>
    <ArticleIdList>
      <ArticleId IdType="doi"/>
    </ArticleIdList>
    <Abstract>Soft actuators driven by pneumatic pressure are promising actuators for mechanical systems in medical, biological, agriculture, welfare fields and so on, because they can ensure high safety for fragile objects from their low mechanical impedance. In this study, a new rubber pneumatic actuator made from silicone rubber was developed. Composed of one chamber and one air-supply tube, it can generate curling motion in two directions by using positive and negative pneumatic pressure. The rubber actuator, for generating bidirectional motion, was designed to achieve an efficient shape by nonlinear finite element method analysis, and was fabricated by a molding and rubber bonding process using excimer light. The fabricated actuator was able to generate curling motion in two directions successfully. The displacement and force characteristics of the actuator were measured by using a motion capture system and a load cell. As an example application of the actuator, a robotic soft hand with three actuators was constructed and its effectiveness was confirmed by experiments.</Abstract>
    <CoiStatement>No potential conflict of interest relevant to this article was reported.</CoiStatement>
    <ObjectList>
      <Object Type="keyword">
        <Param Name="value">Soft actuator</Param>
      </Object>
      <Object Type="keyword">
        <Param Name="value">pneumatic actuator</Param>
      </Object>
      <Object Type="keyword">
        <Param Name="value">bidirectional motion</Param>
      </Object>
      <Object Type="keyword">
        <Param Name="value">nonlinear analysis</Param>
      </Object>
    </ObjectList>
    <ReferenceList/>
  </Article>
  <Article>
    <Journal>
      <PublisherName/>
      <JournalTitle>Acta Medica Okayama</JournalTitle>
      <Issn>0169-1864</Issn>
      <Volume>24</Volume>
      <Issue>10</Issue>
      <PubDate PubStatus="ppublish">
        <Year>2010</Year>
        <Month/>
      </PubDate>
    </Journal>
    <ArticleTitle>Development of an Intelligent Chair Tool System Applying New Intelligent Pneumatic Actuators</ArticleTitle>
    <FirstPage LZero="delete">1503</FirstPage>
    <LastPage>1528</LastPage>
    <Language>EN</Language>
    <AuthorList>
      <Author>
        <FirstName EmptyYN="N">Ahmad 'Athif Mohd</FirstName>
        <LastName>Faudzi</LastName>
        <Affiliation/>
      </Author>
      <Author>
        <FirstName EmptyYN="N">Koichi</FirstName>
        <LastName>Suzumori</LastName>
        <Affiliation/>
      </Author>
      <Author>
        <FirstName EmptyYN="N">Shuichi</FirstName>
        <LastName>Wakimoto</LastName>
        <Affiliation/>
      </Author>
    </AuthorList>
    <PublicationType/>
    <ArticleIdList>
      <ArticleId IdType="doi"/>
    </ArticleIdList>
    <Abstract>This paper develops an Intelligent Chair Tool (ICT) - a new chair-type human and machine interaction seating system powered by 36 intelligent pneumatic actuators. This tool can be used to facilitate investigation of chair shapes from spring and damping effects of seating and backrest surfaces. Each actuator used consists of five extensive elements of encoder, laser strip rod, pressure sensor, valves and PSoC microcontroller incorporated in a single device. By using the ICT, different shapes, spring and damping characteristics can be obtained to aid the design of chairs from the control inputs, i.e., position x, stiffness k(s) and viscous coefficient c. Several control algorithms are presented to realize the communication and control system, and to obtain all data in real-time. The control methodology presented contains an inner force loop and an outer position loop implemented using a unified control system. The specification, development design and experimental evaluation of the ICT control system and actuator used are presented and discussed.</Abstract>
    <CoiStatement>No potential conflict of interest relevant to this article was reported.</CoiStatement>
    <ObjectList>
      <Object Type="keyword">
        <Param Name="value">Intelligent Chair Tool</Param>
      </Object>
      <Object Type="keyword">
        <Param Name="value">seating system</Param>
      </Object>
      <Object Type="keyword">
        <Param Name="value">intelligent pneumatic actuator</Param>
      </Object>
      <Object Type="keyword">
        <Param Name="value">physical human machine interaction</Param>
      </Object>
      <Object Type="keyword">
        <Param Name="value">control application in mechatronics</Param>
      </Object>
    </ObjectList>
    <ReferenceList/>
  </Article>
</ArticleSet>