<?xml version="1.0" encoding="Windows-31J"?>
<ArticleSet xmlns="http://www.openarchives.org/OAI/2.0/">
  <Article>
    <Journal>
      <PublisherName>Elsevier BV</PublisherName>
      <JournalTitle>Acta Medica Okayama</JournalTitle>
      <Issn>0924-4247</Issn>
      <Volume>408</Volume>
      <Issue/>
      <PubDate PubStatus="ppublish">
        <Year>2026</Year>
        <Month/>
      </PubDate>
    </Journal>
    <ArticleTitle>A flexible PVDF-based galloping flow sensor</ArticleTitle>
    <FirstPage LZero="delete">117978</FirstPage>
    <LastPage/>
    <Language>EN</Language>
    <AuthorList>
      <Author>
        <FirstName EmptyYN="N">Mitsuki</FirstName>
        <LastName>Kurose</LastName>
        <Affiliation>Graduate School of Environmental, Life, Natural Science and Technology, Okayama University</Affiliation>
      </Author>
      <Author>
        <FirstName EmptyYN="N">Takefumi</FirstName>
        <LastName>Kanda</LastName>
        <Affiliation>Graduate School of Environmental, Life, Natural Science and Technology, Okayama University</Affiliation>
      </Author>
      <Author>
        <FirstName EmptyYN="N">Yuya</FirstName>
        <LastName>Sato</LastName>
        <Affiliation>Graduate School of Environmental, Life, Natural Science and Technology, Okayama University</Affiliation>
      </Author>
      <Author>
        <FirstName EmptyYN="N">Shuichi</FirstName>
        <LastName>Wakimoto</LastName>
        <Affiliation>Graduate School of Environmental, Life, Natural Science and Technology, Okayama University</Affiliation>
      </Author>
      <Author>
        <FirstName EmptyYN="N">Daisuke</FirstName>
        <LastName>Yamaguchi</LastName>
        <Affiliation>Graduate School of Environmental, Life, Natural Science and Technology, Okayama University</Affiliation>
      </Author>
      <Author>
        <FirstName EmptyYN="N">Shinji</FirstName>
        <LastName>Hiejima</LastName>
        <Affiliation>Graduate School of Environmental, Life, Natural Science and Technology, Okayama University</Affiliation>
      </Author>
      <Author>
        <FirstName EmptyYN="N">Takeji</FirstName>
        <LastName>Ueda</LastName>
        <Affiliation>Hydro-VENUS Co., Ltd., Okayama University</Affiliation>
      </Author>
    </AuthorList>
    <PublicationType/>
    <ArticleIdList>
      <ArticleId IdType="doi"/>
    </ArticleIdList>
    <Abstract>Effective monitoring of low flow velocities in small rivers and irrigation channels is hindered by the power requirements and maintenance costs of existing technologies. This study proposes a novel flexible piezoelectric polymer flow sensor utilizing galloping vibration to detect flow velocity in the low range (&#8804;  0.1&#8201;m/s). The sensor features a flexible cantilever structure composed of a silicone rubber beam embedded with a polyvinylidene fluoride (PVDF) film and a tip pillar. Unlike conventional devices based on flow-induced vibration, the use of low-stiffness materials enables the induction of self-excited vibration even under weak fluid forces. Computational fluid dynamics (CFD) analysis has been conducted to optimize the tip shape; a D-shaped semicylinder is selected over a cylinder and a square prism because the geometry maximizes the lift force per unit mass, ensuring efficient energy conversion. To predict sensor behavior, a coupled mechanical-fluid-electrical model was developed. Specifically, the model accounts for the static deflection angle caused by fluid drag. Water channel experiments demonstrated that sensors with beam thicknesses under 4&#8201;mm successfully generated stable periodic outputs at 0.1&#8201;m/s, a regime previously difficult for galloping-based devices. Conversely, thicker beam which has a thickness of 8&#8201;mm achieved higher outputs at higher velocities but failed to actuate at low speeds. Furthermore, the study showed a vibration suppression phenomenon in flexible beams at high flow velocities due to excessive static deflection, which was accurately reproduced by the analytical model. These findings establish structural stiffness as the critical design parameter for optimizing the operable velocity range of flow sensors.</Abstract>
    <CoiStatement>No potential conflict of interest relevant to this article was reported.</CoiStatement>
    <ObjectList>
      <Object Type="keyword">
        <Param Name="value">Flow velocity sensor</Param>
      </Object>
      <Object Type="keyword">
        <Param Name="value">Piezoelectric polymer</Param>
      </Object>
      <Object Type="keyword">
        <Param Name="value">Flow induced vibration</Param>
      </Object>
      <Object Type="keyword">
        <Param Name="value">Galloping vibration</Param>
      </Object>
    </ObjectList>
    <ReferenceList/>
  </Article>
  <Article>
    <Journal>
      <PublisherName>岡山大学環境管理センター</PublisherName>
      <JournalTitle>Acta Medica Okayama</JournalTitle>
      <Issn>0917-1533</Issn>
      <Volume>33</Volume>
      <Issue/>
      <PubDate PubStatus="ppublish">
        <Year>2012</Year>
        <Month/>
      </PubDate>
    </Journal>
    <ArticleTitle>編集後記</ArticleTitle>
    <FirstPage LZero="delete">69</FirstPage>
    <LastPage>69</LastPage>
    <Language>EN</Language>
    <AuthorList>
      <Author>
        <FirstName EmptyYN="N"/>
        <LastName/>
        <Affiliation/>
      </Author>
    </AuthorList>
    <PublicationType/>
    <ArticleIdList>
      <ArticleId IdType="doi"/>
    </ArticleIdList>
    <Abstract/>
    <CoiStatement>No potential conflict of interest relevant to this article was reported.</CoiStatement>
    <ObjectList/>
    <ReferenceList/>
  </Article>
</ArticleSet>
