このエントリーをはてなブックマークに追加
ID 70528
フルテキストURL
fulltext.pdf 1.49 MB
著者
Takahashi, Yuka Department of Radiology, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Sciences
Higaki, Fumiyo Department of Radiology, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Sciences
Nakamura, Yuko Department of Diagnostic Radiology, Hiroshima University
Higaki, Toru Graduate School of Advanced Science and Engineering, Hiroshima University
Sugaya, Akiko Department of Otolaryngology-Head and Neck Surgery, Faculty of Medicine, Dentistry, and Pharmaceutical Sciences, Okayama University Kaken ID researchmap
Mitsuhashi, Toshiharu Center for Innovative Clinical Medicine, Okayama University Kaken ID researchmap
Kitayama, Takahiro Department of Radiology, Medical Development Field, Okayama University
Morimitsu, Yusuke Department of Radiological Technology, Okayama University Hospital
Inoue, Tomohiro Department of Radiological Technology, Okayama University Hospital
Akagi, Noriaki Department of Radiological Technology, Okayama University Hospital
Matsui, Yusuke Department of Radiology, Faculty of Medicine, Dentistry, and Pharmaceutical Sciences, Okayama University
Iguchi, Toshihiro Department of Radiological Technology, Faculty of Health Sciences, Okayama University Kaken ID
Awai, Kazuo Department of Diagnostic Radiology, Hiroshima University
Hiraki, Takao Department of Radiology, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Sciences Kaken ID publons researchmap
抄録
Purpose: To determine the extent of possible dose reduction with photon-counting detector computed tomography (PCD-CT) while maintaining image quality equivalent to that of energy-integrating detector CT (EID-CT) images at standard dose in the temporal bone.
Materials and methods: PCD-CT and EID-CT imaging quality were compared by visual evaluation of clinical temporal bone images and visual scores with Welch’s t-test at standard dose. A head phantom was used to evaluate imaging quality under dose reduction. The detectability index (d’) of the PCD-CT images at various dose levels and the EID-CT images at standard dose was evaluated. Dose reduction limit with PCD-CT used in the subsequent clinical evaluation was determined as the lowest dose with image quality equal to or better than EID-CT. The clinical equivalence of PCD-CT image quality at the determined reduced dose to that with EID-CT at standard dose was evaluated using visual scores. Equivalence was determined if the 95% confidence intervals of differences did not exceed the equivalence margin of ±1.
Results: At standard doses, PCD-CT images demonstrated significantly higher visual scores than EID-CT images (3.73 vs. 2.56 for incudomalleolar joint, 3.75 vs. 2.63 for stapes, 3.54 vs. 2.52 for cochlea, and 3.58 vs. 2.46 for facial nerve canal; all P 0.001). In the phantom study, the d’ value was 0.15 with EID-CT at standard dose and was 0.12 and 0.17 with PCD-CT at 25% and 50% of the standard dose, respectively. Clinically, the mean visual scores of PCD-CT images at 50% of the standard dose were equivalent to EID-CT images at standard dose in all regions (3.58 vs. 3.12 for incudomalleolar joint, 3.46 vs. 3.19 for stapes, 3.50 vs. 3.08 for cochlea, 3.58 vs. 3.27 for facial nerve canal).
Conclusion: PCD-CT may preserve image quality even at 50% of the standard dose in the temporal bone.
キーワード
PCD-CT
EID-CT
Dose reduction
Temporal bone CT
Incudomalleolar joint
Stapes
発行日
2026-05-20
出版物タイトル
Japanese Journal of Radiology
出版者
Springer Science and Business Media LLC
ISSN
1867-1071
NCID
AA12375935
資料タイプ
学術雑誌論文
言語
英語
OAI-PMH Set
岡山大学
著作権者
© The Author(s) 2026
論文のバージョン
publisher
PubMed ID
DOI
関連URL
isVersionOf https://doi.org/10.1007/s11604-026-02002-9
ライセンス
http://creativecommons.org/licenses/by/4.0/
Citation
Takahashi, Y., Higaki, F., Nakamura, Y. et al. Appropriate dose reduction using photon-counting detector CT for temporal bone imaging: phantom and clinical studies with helical acquisition. Jpn J Radiol (2026). https://doi.org/10.1007/s11604-026-02002-9