<?xml version="1.0" encoding="Windows-31J"?>
<ArticleSet xmlns="http://www.openarchives.org/OAI/2.0/">
  <Article>
    <Journal>
      <PublisherName/>
      <JournalTitle>Acta Medica Okayama</JournalTitle>
      <Issn/>
      <Volume>35</Volume>
      <Issue>3</Issue>
      <PubDate PubStatus="ppublish">
        <Year>1999</Year>
        <Month/>
      </PubDate>
    </Journal>
    <ArticleTitle>Control and performance of a pulse-density-modulated series-resonant inverter for corona discharge processes</ArticleTitle>
    <FirstPage LZero="delete"/>
    <LastPage/>
    <Language>EN</Language>
    <AuthorList>
      <Author>
        <FirstName EmptyYN="N">Hideaki</FirstName>
        <LastName>Fujita</LastName>
        <Affiliation/>
      </Author>
      <Author>
        <FirstName EmptyYN="N">Hirofumi</FirstName>
        <LastName>Akagi</LastName>
        <Affiliation/>
      </Author>
    </AuthorList>
    <PublicationType/>
    <ArticleIdList>
      <ArticleId IdType="doi"/>
    </ArticleIdList>
    <Abstract>&lt;p&gt;&amp;lt;p&amp;gt;This paper presents the control and performance of a pulse-density-modulated (PDM) series-resonant voltage-source inverter developed for corona discharge processes. The PDM inverter produces either a square-wave AC-voltage state or a zero-voltage state at its AC terminals to control the average output voltage under constant DC voltage and operating frequency. This results in a wide range of power control from 0.5% to 100%, even in the corona discharge load with a strong nonlinear characteristic. A 30 kHz 6 kW surface treatment system consisting of a voltage-source PDM inverter, a step-up transformer, and a corona discharge treater shows the establishment of a stable corona discharge in an extremely wide range of power control and, therefore, succeeds in performing both strong and weak surface treatment processes for film &amp;lt;/p&amp;gt;&lt;/p&gt;
</Abstract>
    <CoiStatement>No potential conflict of interest relevant to this article was reported.</CoiStatement>
    <ObjectList>
      <Object Type="keyword">
        <Param Name="value">DC-AC power convertors</Param>
      </Object>
      <Object Type="keyword">
        <Param Name="value">corona</Param>
      </Object>
      <Object Type="keyword">
        <Param Name="value">invertors</Param>
      </Object>
      <Object Type="keyword">
        <Param Name="value">  load (electric)</Param>
      </Object>
      <Object Type="keyword">
        <Param Name="value">power transformers</Param>
      </Object>
      <Object Type="keyword">
        <Param Name="value">resonant</Param>
      </Object>
      <Object Type="keyword">
        <Param Name="value">power convertors</Param>
      </Object>
      <Object Type="keyword">
        <Param Name="value">surface treatment</Param>
      </Object>
      <Object Type="keyword">
        <Param Name="value">voltage control</Param>
      </Object>
    </ObjectList>
    <ReferenceList/>
  </Article>
  <Article>
    <Journal>
      <PublisherName/>
      <JournalTitle>Acta Medica Okayama</JournalTitle>
      <Issn/>
      <Volume>35</Volume>
      <Issue>3</Issue>
      <PubDate PubStatus="ppublish">
        <Year>1999</Year>
        <Month/>
      </PubDate>
    </Journal>
    <ArticleTitle>Control and performance of a pulse-density-modulated series-resonant inverter for corona discharge processes</ArticleTitle>
    <FirstPage LZero="delete">621</FirstPage>
    <LastPage>627</LastPage>
    <Language>EN</Language>
    <AuthorList>
      <Author>
        <FirstName EmptyYN="N">Hideaki</FirstName>
        <LastName>Fujita</LastName>
        <Affiliation/>
      </Author>
      <Author>
        <FirstName EmptyYN="N">Hirofumi</FirstName>
        <LastName>Akagi</LastName>
        <Affiliation/>
      </Author>
    </AuthorList>
    <PublicationType/>
    <ArticleIdList>
      <ArticleId IdType="doi"/>
    </ArticleIdList>
    <Abstract>&lt;p&gt;This paper presents control and performance of a pulse-density-modulated (PDM) series-resonant voltage-source inverter developed for corona discharge processes. The PDM inverter produces either a square-wave ac-voltage state or a zero-voltage state at its ac terminals to control the average output voltage under constant de voltage and operating frequency. This results in a wide range of power control from 0.5% to 100%, even in the corona discharge load with a strong nonlinear characteristic. A 30-kHz 6-kW surface treatment system consisting of a voltage-source PDM inverter, a step-up transformer, and a corona discharge treater shows the establishment of a stable corona discharge in an extremely wide range of power control and, therefore, succeeds in performing both strong and weak surface treatment processes for film. &lt;/p&gt;
</Abstract>
    <CoiStatement>No potential conflict of interest relevant to this article was reported.</CoiStatement>
    <ObjectList>
      <Object Type="keyword">
        <Param Name="value">DC-AC power convertors</Param>
      </Object>
      <Object Type="keyword">
        <Param Name="value">corona</Param>
      </Object>
      <Object Type="keyword">
        <Param Name="value">invertors</Param>
      </Object>
      <Object Type="keyword">
        <Param Name="value">   load (electric)</Param>
      </Object>
      <Object Type="keyword">
        <Param Name="value">power transformers</Param>
      </Object>
      <Object Type="keyword">
        <Param Name="value">resonant power convertors</Param>
      </Object>
      <Object Type="keyword">
        <Param Name="value">surface treatment</Param>
      </Object>
      <Object Type="keyword">
        <Param Name="value">voltage control</Param>
      </Object>
    </ObjectList>
    <ReferenceList/>
  </Article>
  <Article>
    <Journal>
      <PublisherName/>
      <JournalTitle>Acta Medica Okayama</JournalTitle>
      <Issn/>
      <Volume>35</Volume>
      <Issue>3</Issue>
      <PubDate PubStatus="ppublish">
        <Year>1999</Year>
        <Month/>
      </PubDate>
    </Journal>
    <ArticleTitle>A shunt active filter based on voltage detection for harmonic termination of a radial power distribution line</ArticleTitle>
    <FirstPage LZero="delete">638</FirstPage>
    <LastPage>645</LastPage>
    <Language>EN</Language>
    <AuthorList>
      <Author>
        <FirstName EmptyYN="N">Hirofumi</FirstName>
        <LastName>Akagi</LastName>
        <Affiliation/>
      </Author>
      <Author>
        <FirstName EmptyYN="N">Hideaki</FirstName>
        <LastName>Fujita</LastName>
        <Affiliation/>
      </Author>
      <Author>
        <FirstName EmptyYN="N">Keiji</FirstName>
        <LastName>Wada</LastName>
        <Affiliation/>
      </Author>
    </AuthorList>
    <PublicationType/>
    <ArticleIdList>
      <ArticleId IdType="doi"/>
    </ArticleIdList>
    <Abstract>&lt;p&gt;This paper focuses on a shunt active filter based on the detection of harmonic voltages at the point of installation. The objective of the active filter is to attenuate harmonic propagation resulting from series/parallel resonance between capacitors for power factor correction and line inductors in a power distribution line. The active filter acts as a low resistor to the external circuit for harmonic frequencies, and it is installed on the end bus of the power distribution line, just like a 50 &amp;#937; terminator installed on the end terminal of a signal transmission line. Therefore, the function of the active filter is referred to as gharmonic terminationh in this paper. Experimental results obtained from a laboratory system rated at 200 V and 20 kW verify that the active filter for the purpose of harmonic termination has the capability of harmonic damping throughout the power distribution line&lt;/p&gt;
</Abstract>
    <CoiStatement>No potential conflict of interest relevant to this article was reported.</CoiStatement>
    <ObjectList>
      <Object Type="keyword">
        <Param Name="value">active filters</Param>
      </Object>
      <Object Type="keyword">
        <Param Name="value">harmonic distortion</Param>
      </Object>
      <Object Type="keyword">
        <Param Name="value">power distribution lines</Param>
      </Object>
      <Object Type="keyword">
        <Param Name="value">power harmonic filters</Param>
      </Object>
      <Object Type="keyword">
        <Param Name="value">power system harmonics</Param>
      </Object>
    </ObjectList>
    <ReferenceList/>
  </Article>
</ArticleSet>
