start-ver=1.4 cd-journal=joma no-vol=35 cd-vols= no-issue=3 article-no= start-page= end-page= dt-received= dt-revised= dt-accepted= dt-pub-year=1999 dt-pub=19996 dt-online= en-article= kn-article= en-subject= kn-subject= en-title= kn-title=Control and performance of a pulse-density-modulated series-resonant inverter for corona discharge processes en-subtitle= kn-subtitle= en-abstract= kn-abstract=
<p>This paper presents the control and performance of a pulse-density-modulated (PDM) series-resonant voltage-source inverter developed for corona discharge processes. The PDM inverter produces either a square-wave AC-voltage state or a zero-voltage state at its AC terminals to control the average output voltage under constant DC voltage and operating frequency. This results in a wide range of power control from 0.5% to 100%, even in the corona discharge load with a strong nonlinear characteristic. A 30 kHz 6 kW surface treatment system consisting of a voltage-source PDM inverter, a step-up transformer, and a corona discharge treater shows the establishment of a stable corona discharge in an extremely wide range of power control and, therefore, succeeds in performing both strong and weak surface treatment processes for film </p>
en-copyright= kn-copyright= en-aut-name=FujitaHideaki en-aut-sei=Fujita en-aut-mei=Hideaki kn-aut-name= kn-aut-sei= kn-aut-mei= aut-affil-num=1 ORCID= en-aut-name=AkagiHirofumi en-aut-sei=Akagi en-aut-mei=Hirofumi kn-aut-name= kn-aut-sei= kn-aut-mei= aut-affil-num=2 ORCID= affil-num=1 en-affil= kn-affil=Okayama University affil-num=2 en-affil= kn-affil=Okayama University en-keyword=DC-AC power convertors kn-keyword=DC-AC power convertors en-keyword=corona kn-keyword=corona en-keyword=invertors kn-keyword=invertors en-keyword= load (electric) kn-keyword= load (electric) en-keyword=power transformers kn-keyword=power transformers en-keyword=resonant kn-keyword=resonant en-keyword=power convertors kn-keyword=power convertors en-keyword=surface treatment kn-keyword=surface treatment en-keyword=voltage control kn-keyword=voltage control END start-ver=1.4 cd-journal=joma no-vol=35 cd-vols= no-issue=3 article-no= start-page=621 end-page=627 dt-received= dt-revised= dt-accepted= dt-pub-year=1999 dt-pub=19996 dt-online= en-article= kn-article= en-subject= kn-subject= en-title= kn-title=Control and performance of a pulse-density-modulated series-resonant inverter for corona discharge processes en-subtitle= kn-subtitle= en-abstract= kn-abstract=This paper presents control and performance of a pulse-density-modulated (PDM) series-resonant voltage-source inverter developed for corona discharge processes. The PDM inverter produces either a square-wave ac-voltage state or a zero-voltage state at its ac terminals to control the average output voltage under constant de voltage and operating frequency. This results in a wide range of power control from 0.5% to 100%, even in the corona discharge load with a strong nonlinear characteristic. A 30-kHz 6-kW surface treatment system consisting of a voltage-source PDM inverter, a step-up transformer, and a corona discharge treater shows the establishment of a stable corona discharge in an extremely wide range of power control and, therefore, succeeds in performing both strong and weak surface treatment processes for film.
en-copyright= kn-copyright= en-aut-name=FujitaHideaki en-aut-sei=Fujita en-aut-mei=Hideaki kn-aut-name= kn-aut-sei= kn-aut-mei= aut-affil-num=1 ORCID= en-aut-name=AkagiHirofumi en-aut-sei=Akagi en-aut-mei=Hirofumi kn-aut-name= kn-aut-sei= kn-aut-mei= aut-affil-num=2 ORCID= affil-num=1 en-affil= kn-affil=Okayama University affil-num=2 en-affil= kn-affil=Okayama University en-keyword=DC-AC power convertors kn-keyword=DC-AC power convertors en-keyword=corona kn-keyword=corona en-keyword=invertors kn-keyword=invertors en-keyword= load (electric) kn-keyword= load (electric) en-keyword=power transformers kn-keyword=power transformers en-keyword=resonant power convertors kn-keyword=resonant power convertors en-keyword=surface treatment kn-keyword=surface treatment en-keyword=voltage control kn-keyword=voltage control END start-ver=1.4 cd-journal=joma no-vol=35 cd-vols= no-issue=3 article-no= start-page=638 end-page=645 dt-received= dt-revised= dt-accepted= dt-pub-year=1999 dt-pub=19996 dt-online= en-article= kn-article= en-subject= kn-subject= en-title= kn-title=A shunt active filter based on voltage detection for harmonic termination of a radial power distribution line en-subtitle= kn-subtitle= en-abstract= kn-abstract=This paper focuses on a shunt active filter based on the detection of harmonic voltages at the point of installation. The objective of the active filter is to attenuate harmonic propagation resulting from series/parallel resonance between capacitors for power factor correction and line inductors in a power distribution line. The active filter acts as a low resistor to the external circuit for harmonic frequencies, and it is installed on the end bus of the power distribution line, just like a 50 Ω terminator installed on the end terminal of a signal transmission line. Therefore, the function of the active filter is referred to as “harmonic termination” in this paper. Experimental results obtained from a laboratory system rated at 200 V and 20 kW verify that the active filter for the purpose of harmonic termination has the capability of harmonic damping throughout the power distribution line
en-copyright= kn-copyright= en-aut-name=AkagiHirofumi en-aut-sei=Akagi en-aut-mei=Hirofumi kn-aut-name= kn-aut-sei= kn-aut-mei= aut-affil-num=1 ORCID= en-aut-name=FujitaHideaki en-aut-sei=Fujita en-aut-mei=Hideaki kn-aut-name= kn-aut-sei= kn-aut-mei= aut-affil-num=2 ORCID= en-aut-name=WadaKeiji en-aut-sei=Wada en-aut-mei=Keiji kn-aut-name= kn-aut-sei= kn-aut-mei= aut-affil-num=3 ORCID= affil-num=1 en-affil= kn-affil=Okayama University affil-num=2 en-affil= kn-affil=Okayama University affil-num=3 en-affil= kn-affil=Okayama University en-keyword=active filters kn-keyword=active filters en-keyword=harmonic distortion kn-keyword=harmonic distortion en-keyword=power distribution lines kn-keyword=power distribution lines en-keyword=power harmonic filters kn-keyword=power harmonic filters en-keyword=power system harmonics kn-keyword=power system harmonics END