    <ArticleTitle>Modeling and damping of high-frequency leakage currents in PWM inverter-fed AC motor drive systems</ArticleTitle>
    <FirstPage LZero="delete">1105</FirstPage>
    <LastPage>1114</LastPage>
    <Language>EN</Language>
    <AuthorList>
      <Author>
        <FirstName EmptyYN="N">Satoshi</FirstName>
        <LastName>Ogasawara</LastName>
        <Affiliation/>
      </Author>
      <Author>
        <FirstName EmptyYN="N">Hirofumi</FirstName>
        <LastName>Akagi</LastName>
        <Affiliation/>
      </Author>
    </AuthorList>
    <PublicationType/>
    <ArticleIdList>
      <ArticleId IdType="doi"/>
    </ArticleIdList>
    <Abstract>&lt;p&gt;This paper presents an equivalent circuit for high-frequency leakage currents in pulsewidth modulation (PWM) inverter-fed AC motors, which forms a series resonant circuit. The analysis based on the equivalent circuit leads to such a conclusion that the connection of a conventional common-mode choke or reactor in series between the AC terminals of a PWM inverter and those of an AC motor is not effective to reduce the rms and average values of the leakage current, but effective to reduce the peak value. Furthermore, this paper proposes a common-mode transformer which is different in damping principle from the conventional common-mode choke. It is shown theoretically and experimentally that the common-mode transformer is able to reduce the rms value of the leakage current to 25%, where the core used in the common-mode transformer is smaller than that of the conventional common-mode choke&lt;/p&gt;
</Abstract>
    <CoiStatement>No potential conflict of interest relevant to this article was reported.</CoiStatement>
    <ObjectList>
      <Object Type="keyword">
        <Param Name="value">AC motor drives</Param>
      </Object>
      <Object Type="keyword">
        <Param Name="value">PWM invertors</Param>
      </Object>
      <Object Type="keyword">
        <Param Name="value">circuit resonance</Param>
      </Object>
      <Object Type="keyword">
        <Param Name="value">damping</Param>
      </Object>
      <Object Type="keyword">
        <Param Name="value">equivalent circuits</Param>
      </Object>
      <Object Type="keyword">
        <Param Name="value">inductors</Param>
      </Object>
      <Object Type="keyword">
        <Param Name="value">leakage currents</Param>
      </Object>
      <Object Type="keyword">
        <Param Name="value">resonance</Param>
      </Object>
      <Object Type="keyword">
        <Param Name="value">transformers</Param>
      </Object>
    </ObjectList>