    <ArticleTitle>Hemodynamic Changes After Wire Frame Occluders vs. Metal Mesh Devices for Atrial Septal Defect</ArticleTitle>
    <FirstPage LZero="delete">930</FirstPage>
    <LastPage>938</LastPage>
    <Language>EN</Language>
    <AuthorList>
      <Author>
        <FirstName EmptyYN="N">Mitsutaka</FirstName>
        <LastName>Nakashima</LastName>
        <Affiliation>Department of Cardiovascular Medicine, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Sciences</Affiliation>
      </Author>
      <Author>
        <FirstName EmptyYN="N">Yoichi</FirstName>
        <LastName>Takaya</LastName>
        <Affiliation>Department of Cardiovascular Medicine, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Sciences</Affiliation>
      </Author>
      <Author>
        <FirstName EmptyYN="N">Kentaro</FirstName>
        <LastName>Ejiri</LastName>
        <Affiliation>Department of Cardiovascular Medicine, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Sciences</Affiliation>
      </Author>
      <Author>
        <FirstName EmptyYN="N">Takashi</FirstName>
        <LastName>Miki</LastName>
        <Affiliation>Department of Cardiovascular Medicine, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Sciences</Affiliation>
      </Author>
      <Author>
        <FirstName EmptyYN="N">Rie</FirstName>
        <LastName>Nakayama</LastName>
        <Affiliation>Department of Cardiovascular Medicine, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Sciences</Affiliation>
      </Author>
      <Author>
        <FirstName EmptyYN="N">Koji</FirstName>
        <LastName>Nakagawa</LastName>
        <Affiliation>Department of Cardiovascular Medicine, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Sciences</Affiliation>
      </Author>
      <Author>
        <FirstName EmptyYN="N">Teiji</FirstName>
        <LastName>Akagi</LastName>
        <Affiliation>Department of Cardiovascular Medicine, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Sciences</Affiliation>
      </Author>
      <Author>
        <FirstName EmptyYN="N">Kazufumi</FirstName>
        <LastName>Nakamura</LastName>
        <Affiliation>Department of Cardiovascular Medicine, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Sciences</Affiliation>
      </Author>
      <Author>
        <FirstName EmptyYN="N">Shinsuke</FirstName>
        <LastName>Yuasa</LastName>
        <Affiliation>Department of Cardiovascular Medicine, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Sciences</Affiliation>
      </Author>
    </AuthorList>
    <PublicationType/>
    <ArticleIdList>
      <ArticleId IdType="doi"/>
    </ArticleIdList>
    <Abstract>Background: Transcatheter atrial septal defect (ASD) closure is the first treatment option for secundum ASD, but parameters for optimal device selection have not been established. We compared outcomes between occluders with a wire frame and metal mesh devices.&lt;br&gt;
Methods and Results: This study included secundum ASD patients implanted with a wire frame occluder (GORE&#174;CARDIOFORM ASD occluder [GCA]; W.L. Gore &amp; Associates) or metal mesh devices (Amplatzer septal occluder device [Abbott] and Occlutech Figulla Flex II device [Occlutech]). The presence of residual shunt and B-type natriuretic peptide (BNP) levels after implantation were compared. Of the 970 patients with either GCA (n=48) or a metal mesh device (n=922; control), 42 patients from each group were analyzed after propensity score matching. The prevalence of residual shunt was significantly lower in the GCA group 1 day and 1 month after implantation (P&lt;0.001 and P=0.017, respectively), whereas there was no significant difference between the 2 groups 6 months later (P=0.088). BNP levels at 1 month were significantly higher in the GCA group (ratio of change 1.36; 95% confidence interval [CI] 1.01&#8211;1.83), but did not differ significantly between the 2 groups at 6 months (ratio of change 1.04; 95% CI 0.65&#8211;1.65).&lt;br&gt;
Conclusions: Patients implanted with a wire frame occluder had a lower prevalence of residual shunt and a greater increase in BNP levels in the early period after implantation.</Abstract>
    <CoiStatement>No potential conflict of interest relevant to this article was reported.</CoiStatement>
    <ObjectList>
      <Object Type="keyword">
        <Param Name="value">Amplatzer septal occluder</Param>
      </Object>
      <Object Type="keyword">
        <Param Name="value">GORE&#174; CARDIOFORM ASD occluder</Param>
      </Object>
      <Object Type="keyword">
        <Param Name="value">Occlutech Figulla Flex II</Param>
      </Object>
      <Object Type="keyword">
        <Param Name="value">Transcatheter atrial septal defect closure</Param>
      </Object>
    </ObjectList>
    <ReferenceList/>
  </Article>