ID | 31067 |
JaLCDOI | |
FullText URL | |
Author |
Motoyama, Yuzo
|
Abstract | Micromethods for estimation of bilirubin uridine diphosphate-glucuronyl and -xylosyl transferases in liver are described. With these methods, a liver specimen as small as 10 mg is sufficient for assay of either enzyme activity and 15 mg is sufficient for assay of both enzymes. Normal values for livers with minimal elevation of SGOT and minimal histological change were 0.260-0.400 U/g protein for glucuronyl transferase and 0.142-0.302 U/g protein for xylosyl transferase. |
Keywords | bilirubin-DDP-g1ucurony1 transferase
bilirubin-xylosyl transferase
human liver
liver biopsy
|
Amo Type | Article
|
Publication Title |
Acta Medica Okayama
|
Published Date | 1978-10
|
Volume | volume32
|
Issue | issue5
|
Publisher | Okayama University Medical School
|
Start Page | 331
|
End Page | 336
|
ISSN | 0386-300X
|
NCID | AA00508441
|
Content Type |
Journal Article
|
language |
English
|
File Version | publisher
|
Refereed |
True
|
PubMed ID | |
NAID |