Abstract
We performed revision surgery in 2 patients for stem fracture of a cemented tumor prosthesis that occurred more than 25 years after the initial surgery. For revision, the global modular replacement system (GMRS) was used. However, as bone cement in the bone could not be adequately removed, stems with respective diameters of 11 and 12.5 mm were used. In revision surgery for cemented tumor prostheses, adequate removal of residual bone cement is optimal. However, when there is a risk of fracture, it may be appropriate to insert a thicker stem after reaming the femoral canal as much as possible, and then fix the stem using the cement-in-cement method.
Keywords
revision
custom-made tumor prosthesis
malignant bone tumor
Published Date
2017-02
Publication Title
Acta Medica Okayama
Volume
volume71
Issue
issue1
Publisher
Okayama University Medical School
Start Page
69
End Page
72
ISSN
0386-300X
NCID
AA00508441
Content Type
Journal Article
language
English
Copyright Holders
CopyrightⒸ 2017 by Okayama University Medical School
File Version
publisher
Refereed
True
PubMed ID
Amo Type
Case Report
Submission Path
amo/vol71/iss1/9
JaLCDOI