| Abstract | The authors present a combined system with a passive filter and a small-rated active filter, both connected in series with each other. The passive filter removes load produced harmonics just as a conventional filter does. The active filter plays a role in improving the filtering characteristics of the passive filter. This results in a great reduction of the required rating of the active filter and in eliminating all the limitations faced by using only the passive filter, leading to a practical and economical system. The active filter has a much smaller rating than a conventional active filter. Experimental results obtained from a prototype model are shown to verify the theory developed |