このエントリーをはてなブックマークに追加
ID 68949
FullText URL
fulltext.pdf 1.34 MB
suppl.pdf 1.05 MB
Author
Nakashima, Mitsutaka Department of Cardiovascular Medicine, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Sciences
Takaya, Yoichi Department of Cardiovascular Medicine, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Sciences ORCID Kaken ID
Ejiri, Kentaro Department of Cardiovascular Medicine, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Sciences ORCID publons researchmap
Miki, Takashi Department of Cardiovascular Medicine, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Sciences
Nakayama, Rie Department of Cardiovascular Medicine, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Sciences
Nakagawa, Koji Department of Cardiovascular Medicine, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Sciences
Akagi, Teiji Department of Cardiovascular Medicine, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Sciences ORCID Kaken ID publons researchmap
Nakamura, Kazufumi Department of Cardiovascular Medicine, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Sciences Kaken ID publons researchmap
Yuasa, Shinsuke Department of Cardiovascular Medicine, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Sciences
Abstract
Background: Transcatheter atrial septal defect (ASD) closure is the first treatment option for secundum ASD, but parameters for optimal device selection have not been established. We compared outcomes between occluders with a wire frame and metal mesh devices.
Methods and Results: This study included secundum ASD patients implanted with a wire frame occluder (GORE®CARDIOFORM ASD occluder [GCA]; W.L. Gore & Associates) or metal mesh devices (Amplatzer septal occluder device [Abbott] and Occlutech Figulla Flex II device [Occlutech]). The presence of residual shunt and B-type natriuretic peptide (BNP) levels after implantation were compared. Of the 970 patients with either GCA (n=48) or a metal mesh device (n=922; control), 42 patients from each group were analyzed after propensity score matching. The prevalence of residual shunt was significantly lower in the GCA group 1 day and 1 month after implantation (P<0.001 and P=0.017, respectively), whereas there was no significant difference between the 2 groups 6 months later (P=0.088). BNP levels at 1 month were significantly higher in the GCA group (ratio of change 1.36; 95% confidence interval [CI] 1.01–1.83), but did not differ significantly between the 2 groups at 6 months (ratio of change 1.04; 95% CI 0.65–1.65).
Conclusions: Patients implanted with a wire frame occluder had a lower prevalence of residual shunt and a greater increase in BNP levels in the early period after implantation.
Keywords
Amplatzer septal occluder
GORE® CARDIOFORM ASD occluder
Occlutech Figulla Flex II
Transcatheter atrial septal defect closure
Published Date
2025-06-25
Publication Title
Circulation Journal
Volume
volume89
Issue
issue7
Publisher
Japanese Circulation Society
Start Page
930
End Page
938
ISSN
1346-9843
NCID
AA11591968
Content Type
Journal Article
language
English
OAI-PMH Set
岡山大学
Copyright Holders
© 2025, THE JAPANESE CIRCULATION SOCIETY
File Version
publisher
PubMed ID
DOI
CRID
Related Url
isVersionOf https://doi.org/10.1253/circj.cj-24-0966
License
https://creativecommons.org/licenses/by-nc-nd/4.0/