ID | 68949 |
FullText URL | |
Author |
Nakashima, Mitsutaka
Department of Cardiovascular Medicine, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Sciences
Takaya, Yoichi
Department of Cardiovascular Medicine, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Sciences
ORCID
Kaken ID
Ejiri, Kentaro
Department of Cardiovascular Medicine, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Sciences
ORCID
publons
researchmap
Miki, Takashi
Department of Cardiovascular Medicine, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Sciences
Nakayama, Rie
Department of Cardiovascular Medicine, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Sciences
Nakagawa, Koji
Department of Cardiovascular Medicine, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Sciences
Akagi, Teiji
Department of Cardiovascular Medicine, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Sciences
ORCID
Kaken ID
publons
researchmap
Nakamura, Kazufumi
Department of Cardiovascular Medicine, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Sciences
Kaken ID
publons
researchmap
Yuasa, Shinsuke
Department of Cardiovascular Medicine, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Sciences
|
Abstract | Background: Transcatheter atrial septal defect (ASD) closure is the first treatment option for secundum ASD, but parameters for optimal device selection have not been established. We compared outcomes between occluders with a wire frame and metal mesh devices.
Methods and Results: This study included secundum ASD patients implanted with a wire frame occluder (GORE®CARDIOFORM ASD occluder [GCA]; W.L. Gore & Associates) or metal mesh devices (Amplatzer septal occluder device [Abbott] and Occlutech Figulla Flex II device [Occlutech]). The presence of residual shunt and B-type natriuretic peptide (BNP) levels after implantation were compared. Of the 970 patients with either GCA (n=48) or a metal mesh device (n=922; control), 42 patients from each group were analyzed after propensity score matching. The prevalence of residual shunt was significantly lower in the GCA group 1 day and 1 month after implantation (P<0.001 and P=0.017, respectively), whereas there was no significant difference between the 2 groups 6 months later (P=0.088). BNP levels at 1 month were significantly higher in the GCA group (ratio of change 1.36; 95% confidence interval [CI] 1.01–1.83), but did not differ significantly between the 2 groups at 6 months (ratio of change 1.04; 95% CI 0.65–1.65). Conclusions: Patients implanted with a wire frame occluder had a lower prevalence of residual shunt and a greater increase in BNP levels in the early period after implantation. |
Keywords | Amplatzer septal occluder
GORE® CARDIOFORM ASD occluder
Occlutech Figulla Flex II
Transcatheter atrial septal defect closure
|
Published Date | 2025-06-25
|
Publication Title |
Circulation Journal
|
Volume | volume89
|
Issue | issue7
|
Publisher | Japanese Circulation Society
|
Start Page | 930
|
End Page | 938
|
ISSN | 1346-9843
|
NCID | AA11591968
|
Content Type |
Journal Article
|
language |
English
|
OAI-PMH Set |
岡山大学
|
Copyright Holders | © 2025, THE JAPANESE CIRCULATION SOCIETY
|
File Version | publisher
|
PubMed ID | |
DOI | |
CRID | |
Related Url | isVersionOf https://doi.org/10.1253/circj.cj-24-0966
|
License | https://creativecommons.org/licenses/by-nc-nd/4.0/
|