このエントリーをはてなブックマークに追加
ID 61897
JaLCDOI
FullText URL
75_2_187.pdf 7.64 MB
Author
Fujiwara, Yuta Division of Clinical Radiology Service, Okayama Central Hospital
Sasaki, Tomoaki Department of Radiological Technology, Graduate School of Health Sciences, Okayama University
Muto, Yuki Department of Radiological Technology, Graduate School of Health Sciences, Okayama University
Hirano, Masaki Department of Radiological Technology, Graduate School of Health Sciences, Okayama University publons researchmap
Kamizaki, Ryo Department of Radiological Technology, Faculty of Health Sciences, Okayama University
Murakami, Kaito Department of Radiological Technology, Faculty of Health Sciences, Okayama University
Miura, Naoya Department of Radiological Technology, Faculty of Health Sciences, Okayama University
Fujibuchi, Yutaka Department of Radiological Technology, Faculty of Health Sciences, Okayama University
Ohmukai, Nayu Department of Radiological Technology, Faculty of Health Sciences, Okayama University
Ueda, Nao Department of Radiological Technology, Faculty of Health Sciences, Okayama University
Sugimoto, Kouhei Department of Radiological Technology, Graduate School of Health Sciences, Okayama University
Ota, Kazuhiro Division of Clinical Radiology Service, Okayama Central Hospital
Kamihoriuchi, Yoshiki Division of Clinical Radiology Service, Okayama Central Hospital
Sasaki, Tomoko Division of Clinical Radiology Service, Okayama Central Hospital
Kaneshige, Souichirou Department of Radiology, Okayama Central Hospital
Abstract
The aim of this study is to evaluate how metallic artifacts in the lumbar spine can affect images obtained from magnetic resonance (MR) sequences. We performed a phantom experiment by scanning an agar containing an orthopedic metallic implant using 64-channel multidetector row computed tomography (CT) and a 3-tesla MR unit. We compared the reproducibility in each measurement, enlargement or reduction ratio of the CT and MR measurements, and signal deviation in each voxel from the control. The reproducibility on CT and multiacquisition variable-resonance image combination selective (MAVRIC SL) was good, but that on the other MR sequences showed either fixed bias or proportional bias. The reduction ratios of the distance between the nails were significantly smaller in MAVRIC SL than in the other MR sequences after CT measurements (p<0.001, respectively). MAVRIC SL was able to reduce the metallic artifact, permitting observation of the tissue surrounding the metal with good reproducibility.
Keywords
metallic artifact reduction
implant
MAVRIC SL
Amo Type
Original Article
Publication Title
Acta Medica Okayama
Published Date
2021-04
Volume
volume75
Issue
issue2
Publisher
Okayama University Medical School
Start Page
187
End Page
197
ISSN
0386-300X
NCID
AA00508441
Content Type
Journal Article
language
English
Copyright Holders
CopyrightⒸ 2021 by Okayama University Medical School
File Version
publisher
Refereed
True
PubMed ID
NAID