<?xml version="1.0" encoding="Windows-31J"?>
<ArticleSet xmlns="http://www.openarchives.org/OAI/2.0/">
  <Article>
    <Journal>
      <PublisherName/>
      <JournalTitle>Acta Medica Okayama</JournalTitle>
      <Issn/>
      <Volume>32</Volume>
      <Issue>4</Issue>
      <PubDate PubStatus="ppublish">
        <Year>1996</Year>
        <Month/>
      </PubDate>
    </Journal>
    <ArticleTitle>Numerical and experimental investigations of current distribution at the joint between AC superconducting cable and normal conducting plate</ArticleTitle>
    <FirstPage LZero="delete">2962</FirstPage>
    <LastPage>2965</LastPage>
    <Language>EN</Language>
    <AuthorList>
      <Author>
        <FirstName EmptyYN="N">Norio</FirstName>
        <LastName>Takahashi</LastName>
        <Affiliation/>
      </Author>
      <Author>
        <FirstName EmptyYN="N">Kazuhiro</FirstName>
        <LastName>Muramatsu</LastName>
        <Affiliation/>
      </Author>
      <Author>
        <FirstName EmptyYN="N">Masanori</FirstName>
        <LastName>Nakano</LastName>
        <Affiliation/>
      </Author>
      <Author>
        <FirstName EmptyYN="N">Y.</FirstName>
        <LastName>Sato</LastName>
        <Affiliation/>
      </Author>
      <Author>
        <FirstName EmptyYN="N">T.</FirstName>
        <LastName>Kondo</LastName>
        <Affiliation/>
      </Author>
    </AuthorList>
    <PublicationType/>
    <ArticleIdList>
      <ArticleId IdType="doi"/>
    </ArticleIdList>
    <Abstract>&lt;p&gt;The effect of the configuration of the joint between an ac superconducting cable and a normal conducting plate on the current distribution and the joule loss is investigated by using the 3-D finite element method. It is shown that the concentration of current can be reduced by changing the configuration of joint. The effectiveness of the analysis is verified by measuring the current distribution on the surface of a copper plate and the quenching current &lt;/p&gt;
</Abstract>
    <CoiStatement>No potential conflict of interest relevant to this article was reported.</CoiStatement>
    <ObjectList>
      <Object Type="keyword">
        <Param Name="value">cable jointing</Param>
      </Object>
      <Object Type="keyword">
        <Param Name="value">current distribution</Param>
      </Object>
      <Object Type="keyword">
        <Param Name="value">finite element analysis</Param>
      </Object>
      <Object Type="keyword">
        <Param Name="value">superconducting cables</Param>
      </Object>
    </ObjectList>
    <ReferenceList/>
  </Article>
</ArticleSet>