    <ArticleTitle>Study on cause of quenching at the joint between multifilamentary superconducting cable and normal conducting cable using 3D FEM</ArticleTitle>
    <FirstPage LZero="delete">2826</FirstPage>
    <LastPage>2828</LastPage>
    <Language>EN</Language>
    <AuthorList>
      <Author>
        <FirstName EmptyYN="N">Norio</FirstName>
        <LastName>Takahashi</LastName>
        <Affiliation/>
      </Author>
      <Author>
        <FirstName EmptyYN="N">Takayoshi</FirstName>
        <LastName>Nakata</LastName>
        <Affiliation/>
      </Author>
      <Author>
        <FirstName EmptyYN="N">Y.</FirstName>
        <LastName>Fujii</LastName>
        <Affiliation/>
      </Author>
      <Author>
        <FirstName EmptyYN="N">K.</FirstName>
        <LastName>Funaki</LastName>
        <Affiliation/>
      </Author>
      <Author>
        <FirstName EmptyYN="N">M.</FirstName>
        <LastName>Takeo</LastName>
        <Affiliation/>
      </Author>
    </AuthorList>
    <PublicationType/>
    <ArticleIdList>
      <ArticleId IdType="doi"/>
    </ArticleIdList>
    <Abstract>&lt;p&gt;Investigates the cause of quenching at the joint between a multifilamentary superconducting cable and a normal conducting cable. The 3D current distribution is analyzed. It is found that the cause of quenching is the extreme concentration of current in the joint due to the pronounced skin effect at liquid helium temperature. The mechanism of the concentration of current which is affected by the twist pitch and skin depth is also clarified quantitatively by numerical analysis&lt;/p&gt;
</Abstract>
    <CoiStatement>No potential conflict of interest relevant to this article was reported.</CoiStatement>
    <ObjectList>
      <Object Type="keyword">
        <Param Name="value">cable jointing</Param>
      </Object>
      <Object Type="keyword">
        <Param Name="value">finite element analysis</Param>
      </Object>
      <Object Type="keyword">
        <Param Name="value">    quenching (thermal)</Param>
      </Object>
      <Object Type="keyword">
        <Param Name="value">skin effect</Param>
      </Object>
      <Object Type="keyword">
        <Param Name="value">superconducting cables</Param>
      </Object>
    </ObjectList>
    <ReferenceList/>
  </Article>
  <Article>
    <Journal>
      <PublisherName/>
      <JournalTitle>Acta Medica Okayama</JournalTitle>
      <Issn/>
      <Volume>28</Volume>
      <Issue>5</Issue>
      <PubDate PubStatus="ppublish">
        <Year>1992</Year>
        <Month/>
      </PubDate>
    </Journal>
    <ArticleTitle>An improved method for determining the DC magnetization curve using a ring specimen</ArticleTitle>
    <FirstPage LZero="delete">2456</FirstPage>
    <LastPage>2458</LastPage>
    <Language>EN</Language>
    <AuthorList>
      <Author>
        <FirstName EmptyYN="N">Takayoshi</FirstName>
        <LastName>Nakata</LastName>
        <Affiliation/>
      </Author>
      <Author>
        <FirstName EmptyYN="N">N.</FirstName>
        <LastName>Takahashi</LastName>
        <Affiliation/>
      </Author>
      <Author>
        <FirstName EmptyYN="N">K.</FirstName>
        <LastName>Fujiwara</LastName>
        <Affiliation/>
      </Author>
      <Author>
        <FirstName EmptyYN="N">Masanori</FirstName>
        <LastName>Nakano</LastName>
        <Affiliation/>
      </Author>
      <Author>
        <FirstName EmptyYN="N">Y.</FirstName>
        <LastName>Ogura</LastName>
        <Affiliation/>
      </Author>
    </AuthorList>
    <PublicationType/>
    <ArticleIdList>
      <ArticleId IdType="doi"/>
    </ArticleIdList>
    <Abstract>&lt;p&gt;When the DC magnetization curve (B-H) of nonoriented material is measured in a ring specimen, there is an intrinsic error due to the assumption that the mean magnetic path length is equal to the mean geometric path length. A novel method for determining the B-H curve accurately is proposed. The validity of the method is verified by experiments&lt;/p&gt;
</Abstract>
    <CoiStatement>No potential conflict of interest relevant to this article was reported.</CoiStatement>
    <ObjectList>
      <Object Type="keyword">
        <Param Name="value">magnetic variables measurement</Param>
      </Object>
      <Object Type="keyword">
        <Param Name="value">magnetisation</Param>
      </Object>
    </ObjectList>
    <ReferenceList/>
  </Article>
  <Article>
    <Journal>
      <PublisherName/>
      <JournalTitle>Acta Medica Okayama</JournalTitle>
      <Issn/>
      <Volume>28</Volume>
      <Issue>5</Issue>
      <PubDate PubStatus="ppublish">
        <Year>1992</Year>
        <Month/>
      </PubDate>
    </Journal>
    <ArticleTitle>A low loss transformer using a rotating magnetic field</ArticleTitle>
    <FirstPage LZero="delete">2163</FirstPage>
    <LastPage>2165</LastPage>
    <Language>EN</Language>
    <AuthorList>
      <Author>
        <FirstName EmptyYN="N">Takayoshi</FirstName>
        <LastName>Nakata</LastName>
        <Affiliation/>
      </Author>
      <Author>
        <FirstName EmptyYN="N">N.</FirstName>
        <LastName>Takahashi</LastName>
        <Affiliation/>
      </Author>
      <Author>
        <FirstName EmptyYN="N">K.</FirstName>
        <LastName>Fujiwara</LastName>
        <Affiliation/>
      </Author>
      <Author>
        <FirstName EmptyYN="N">Masanori</FirstName>
        <LastName>Nakano</LastName>
        <Affiliation/>
      </Author>
      <Author>
        <FirstName EmptyYN="N">M.</FirstName>
        <LastName>Nagao</LastName>
        <Affiliation/>
      </Author>
    </AuthorList>
    <PublicationType/>
    <ArticleIdList>
      <ArticleId IdType="doi"/>
    </ArticleIdList>
    <Abstract>&lt;p&gt;A type of transformer with reduced iron loss, which is excited by a semirotating magnetic field, has been investigated. Factors (method of excitation and slits in the core) affecting iron losses are examined. The iron loss of this type of transformer can be reduced below the material loss as measured for normal AC excitation by introducing a slit which cuts the eddy current path, and by improving the method of excitation&lt;/p&gt;
</Abstract>
    <CoiStatement>No potential conflict of interest relevant to this article was reported.</CoiStatement>
    <ObjectList>
      <Object Type="keyword">
        <Param Name="value">eddy current losses</Param>
      </Object>
      <Object Type="keyword">
        <Param Name="value">magnetic leakage</Param>
      </Object>
      <Object Type="keyword">
        <Param Name="value">transformers</Param>
      </Object>
    </ObjectList>
    <ReferenceList/>
  </Article>
</ArticleSet>