    <ArticleTitle>Non-enzymatic detection of glucose levels in human blood plasma by a graphene oxide-modified organic transistor sensor</ArticleTitle>
    <FirstPage LZero="delete">2425</FirstPage>
    <LastPage>2428</LastPage>
    <Language>EN</Language>
    <AuthorList>
      <Author>
        <FirstName EmptyYN="N">Haonan</FirstName>
        <LastName>Fan</LastName>
        <Affiliation>Institute of Industrial Science, The University of Tokyo</Affiliation>
      </Author>
      <Author>
        <FirstName EmptyYN="N">Yui</FirstName>
        <LastName>Sasaki</LastName>
        <Affiliation>Institute of Industrial Science, The University of Tokyo</Affiliation>
      </Author>
      <Author>
        <FirstName EmptyYN="N">Qi</FirstName>
        <LastName>Zhou</LastName>
        <Affiliation>Institute of Industrial Science, The University of Tokyo</Affiliation>
      </Author>
      <Author>
        <FirstName EmptyYN="N">Wei</FirstName>
        <LastName>Tang</LastName>
        <Affiliation>Institute of Industrial Science, The University of Tokyo</Affiliation>
      </Author>
      <Author>
        <FirstName EmptyYN="N">Yuta</FirstName>
        <LastName>Nishina</LastName>
        <Affiliation>Research Core for Interdisciplinary Sciences, Okayama University</Affiliation>
      </Author>
      <Author>
        <FirstName EmptyYN="N">Tsuyoshi</FirstName>
        <LastName>Minami</LastName>
        <Affiliation>Institute of Industrial Science, The University of Tokyo</Affiliation>
      </Author>
    </AuthorList>
    <PublicationType/>
    <ArticleIdList>
      <ArticleId IdType="doi"/>
    </ArticleIdList>
    <Abstract>We herein report an organic transistor functionalized with a phenylboronic acid derivative and graphene oxide for the quantification of plasma glucose levels, which has been achieved by the minimization of interferent effects derived from physical protein adsorption on the detection electrode.</Abstract>