The body surface peripheral circulation in 12 cases, including 9 patients with diabetes mellitus who were suffering coldness, numbness or pain in their feet, and 3 healthy volunteers was examined using Laser-Doppler blood flowmetry. At the same time, the body surface temperature was estimated by thermography. Thermographic results were analyzed quantitatively by calculating a recovery ratio as : Recovery ratio = [Total counts of thermography(Pixels) over temperature (T) after cold loading] ÷ [Initial counts over T before cold loading] x 100(%). The recovery ratio and the blood flow were correlated, r=0.68, p