JaLCDOI 10.18926/AMO/55439
フルテキストURL 71_5_413.pdf
著者 Furumatsu, Takayuki| Kodama, Yuya| Kamatsuki, Yusuke| Hino, Tomohito| Ozaki, Toshifumi|
抄録 Extrusion of the medial meniscus (MM) is associated with knee joint pain in osteoarthritic knees. The relationships among MM radial/oblique tears, MM extrusion (MME), and the effect of arthroscopic meniscal repair are not established. Here we evaluated the effects of arthroscopic all-inside MM repair on MME and the clinical outcomes in patients with radially oriented MM tears and mildly osteoarthritic knees. Twenty patients with a symptomatic radial or oblique tear of the MM posterior segment, MME ≥2.5 mm, and mildly osteoarthritic knees were treated using FasT-Fix 360 All-inside Meniscal Suture devices. We used magnetic resonance imaging (MRI) to measure the patients’ MM body width (MMBW), absolute MME, and relative MME. The Japanese Knee Injury and Osteoarthritis Outcome Score, Lysholm, Tegner, IKDC Subjective Knee Evaluation, and Visual Analogue Scale scores were obtained. Arthroscopic all-inside MM repair prevented increases of absolute and relative MME. The preoperative and 3- and 12-month MRI-based MMBW values were similar. Over a 24-month follow-up after the MM repairs, the clinical scores showed significant improvements. Our results suggest that all-inside meniscal repairs would be useful in preventing the progression of MME in patients suffering from symptomatic MM radial/oblique tears associated with mildly osteoarthritic knees.
キーワード medial meniscus radial/oblique tear meniscal repair meniscal extrusion osteoarthritic knee
Amo Type Original Article
発行日 2017-10
出版物タイトル Acta Medica Okayama
71巻
5号
出版者 Okayama University Medical School
開始ページ 413
終了ページ 418
ISSN 0386-300X
NCID AA00508441
資料タイプ 学術雑誌論文
言語 English
著作権者 CopyrightⒸ 2017 by Okayama University Medical School
論文のバージョン publisher
査読 有り
PubMed ID 29042699
JaLCDOI 10.18926/AMO/57713
フルテキストURL 73_6_495.pdf
著者 Masuda, Shin| Furumatsu, Takayuki| Okazaki, Yoshiki| Kamatsuki, Yusuke| Okazaki, Yuki| Kodama, Yuya| Hiranaka, Takaaki| Nakata, Eiji| Ozaki, Toshifumi|
抄録 Medial meniscus posterior root tear causes rapid knee cartilage degradation by inducing posteromedial displacement of the medial meniscus. We evaluated medial meniscus posterior extrusion before and after pullout repair for medial meniscus posterior root tear using magnetic resonance images. Twenty-eight patients with symptomatic medial meniscus posterior root tear were included. The inclusion criteria were: acute (< 3 months) or chronic (≥3 months) medial meniscus posterior root tear after painful popping events. The exclusion criteria were: other meniscus and anterior cruciate ligament injuries. We measured medial meniscus posterior extrusion and medial meniscus anteroposterior interval at knee flexion angles of 10° and 90° preoperatively and at 3 months postoperatively. The posterior extrusion at 90° knee flexion decreased from 4.42±1.38 mm preoperatively to 3.09±1.06 mm (p<0.001) postoperatively, while at 10° knee flexion it was −4.17±1.63 mm preoperatively and −3.77±1.72mm postoperatively, showing no significant change. The anteroposterior interval at 10° knee flexion increased from 19.74±4.27 mm preoperatively to 22.15±5.10 mm postoperatively (p<0.001); at 90° knee flexion, it increased from 16.81±4.51 mm preoperatively to 19.20±4.30 mm postoperatively (p<0.001). Medial meniscus posterior extrusion and movement decreased after pullout repair. Pullout repair for medial meniscus posterior root tear improves medial meniscus posterior extrusion, especially at 90° knee flexion.
キーワード medial meniscus posterior root tear pullout repair extrusion open magnetic resonance imaging
Amo Type Original Article
発行日 2019-12
出版物タイトル Acta Medica Okayama
73巻
6号
出版者 Okayama University Medical School
開始ページ 495
終了ページ 501
ISSN 0386-300X
NCID AA00508441
資料タイプ 学術雑誌論文
言語 English
著作権者 CopyrightⒸ 2019 by Okayama University Medical School
論文のバージョン publisher
査読 有り
PubMed ID 31871331
Web of Science KeyUT 000503431400004
JaLCDOI 10.18926/AMO/57714
フルテキストURL 73_6_503.pdf
著者 Kamatsuki, Yusuke| Furumatsu, Takayuki| Miyazawa, Shinichi| Kodama, Yuya| Hino, Tomohito| Okazaki, Yoshiki| Masuda, Shin| Okazaki, Yuki| Noda, Tomoyuki| Yamakawa, Yasuaki| Tetsunaga, Tomoko| Ozaki, Toshifumi|
抄録 Clinical studies have demonstrated that transtibial pullout repair led to favorable midterm outcomes in patients with medial meniscus posterior root tears (MMPRTs) although medial meniscal extrusion (MME) continued to be present. It has been unclear whether these residual postoperative MMEs existed after the pullout repair or had progressed at the very short-term evaluation after surgery. We sought to determine which characteristics of patients with MMPRTs influence the incidence of postoperative MME. The cases of 23 patients whose date of injury was known were analyzed. All patients underwent MMPRT pullout fixation. Preoperative and 3-month postoperative magnetic resonance imaging (MRI) examinations were performed. MME was retrospectively assessed on the mid-coronal plane of MRI scans. The preoperative and postoperative MME values were 4.2±1.2 mm and 4.3±1.5 mm, respectively (p=0.559). Pullout repair surgery was performed significantly earlier after the MMPRT-specific injury in patients whose postoperative MME improved compared to the patients whose MME did not improve (p<0.001). Our findings demonstrated that an early transtibial pullout repair of an MMPRT was more effective in reducing MME than a late repair. Surgeons should not miss the optimal timing for the pullout repair of an MMPRT, considering the period from the injury and the preoperative MME.
キーワード medial meniscus posterior root tear pullout repair medial meniscus extrusion magnetic resonance imaging
Amo Type Original Article
発行日 2019-12
出版物タイトル Acta Medica Okayama
73巻
6号
出版者 Okayama University Medical School
開始ページ 503
終了ページ 510
ISSN 0386-300X
NCID AA00508441
資料タイプ 学術雑誌論文
言語 English
著作権者 CopyrightⒸ 2019 by Okayama University Medical School
論文のバージョン publisher
査読 有り
PubMed ID 31871332
Web of Science KeyUT 000503431400005
JaLCDOI 10.18926/AMO/57717
フルテキストURL 73_6_523.pdf
著者 Hiranaka, Takaaki| Furumatsu, Takayuki| Okazaki, Yoshiki| Kamatsuki, Yusuke| Masuda, Shin| Okazaki, Yuki| Takihira, Shota| Miyazawa, Shinichi| Nakata, Eiji| Ozaki, Toshifumi|
抄録 The case of an individual with a bilateral anterior cruciate ligament (ACL) tear combined with a medial meniscus (MM) posterior root tear is described. A 34-year-old Japanese man with bilateral ACL rupture that occurred > 10 years earlier was diagnosed with bilateral ACL tear combined with MM posterior root tear (MMPRT). We performed a transtibial pullout repair of the MMPRT with ACL reconstruction. The tibial tunnels for the MM posterior root repair and ACL reconstruction were created separately. Postoperatively, a good clinical outcome and meniscal healing were obtained. Our surgical technique may thus contribute to anatomical MM posterior root repair and ACL reconstruction.
キーワード bilateral anterior cruciate ligament tear medial meniscus posterior root tear pullout repair case report
Amo Type Case Report
発行日 2019-12
出版物タイトル Acta Medica Okayama
73巻
6号
出版者 Okayama University Medical School
開始ページ 523
終了ページ 528
ISSN 0386-300X
NCID AA00508441
資料タイプ 学術雑誌論文
言語 English
著作権者 CopyrightⒸ 2019 by Okayama University Medical School
論文のバージョン publisher
査読 有り
PubMed ID 31871335
Web of Science KeyUT 000503431400008
著者 古松 毅之| 尾﨑 敏文| 浅原 弘嗣|
発行日 2010-08-02
出版物タイトル 岡山医学会雑誌
122巻
2号
資料タイプ 学術雑誌論文
フルテキストURL OTSR105_1_113.pdf Fig.pdf
著者 Okazaki, Yuki| Furumatsu, Takayuki| Kodama, Yuya| Hino, Tomohito| Kamatsuki, Yusuke| Okazaki, Yoshiki| Masuda, Shin| Miyazawa, Shinichi| Endo, Hirosuke| Tetsunaga, Tomonori| Yamada, Kazuki| Ozaki, Toshifumi|
キーワード Magnetic resonance imaging Medial meniscus Posterior root tear Tibial rotation Transtibial pullout repair
発行日 2019-02-28
出版物タイトル Orthopaedics & Traumatology: Surgery & Research
105巻
1号
出版者 Elsevier
開始ページ 113
終了ページ 117
ISSN 18770568
資料タイプ 学術雑誌論文
言語 Japanese
OAI-PMH Set 岡山大学
論文のバージョン author
PubMed ID 30482466
DOI 10.1016/j.otsr.2018.10.005
Web of Science KeyUT 000456541300019
関連URL isVersionOf https://doi.org/10.1016/j.otsr.2018.10.005
著者 尾崎 敏文|
発行日 1989-06
出版物タイトル 岡山医学会雑誌
101巻
5-6号
資料タイプ 学術雑誌論文
JaLCDOI 10.18926/AMO/40011
フルテキストURL fulltext.pdf
著者 Honda, Mitsugi| Arita, Seizaburo| Mitani, Shigeru| Takeda, Yoshihiro| Ozaki, Toshifumi| Inamura, Keiji| Kanazawa, Susumu|
抄録 Plain X-ray radiography is frequently used for the diagnosis of developmental dislocation of the hip (DDH). The aim of this study was to construct a diagnostic support system for DDH based on clinical findings obtained from the X-ray images of 154 female infants with confirmed diagnoses made by orthopedists. The data for these subjects were divided into 2 groups. The Min-Max method of nonlinear analysis was applied to the data from Group 1 to construct the diagnostic support system based on the measurement of 4 items in X-ray images:the outward displacement rate, upward displacement rate, OE angle, and alpha angle. This system was then applied to the data from Group 2, and the results were compared between the 2 groups to verify the reliability of the system. We obtained good results that matched the confirmed diagnoses of orthopedists with an accuracy of 85.9%.
キーワード X-ray image developmental dislocation of the hip acetabular dysplasia radiographic findings nonlinear multivariate analysis infant hip joint diagnostic support system
Amo Type Original Article
発行日 2010-06
出版物タイトル Acta Medica Okayama
64巻
3号
出版者 Okayama University Medical School
開始ページ 189
終了ページ 196
ISSN 0386-300X
NCID AA00508441
資料タイプ 学術雑誌論文
言語 English
著作権者 Okayama University Medical School
論文のバージョン publisher
査読 有り
PubMed ID 20596130
Web of Science KeyUT 000279094300005
タイトル(別表記) Japanese guidelines for the treatment of hip fractures in the elderly
フルテキストURL 122_253.pdf
著者 野田 知之| 尾﨑 敏文|
出版物タイトル 岡山医学会雑誌
発行日 2010-12-01
122巻
3号
開始ページ 253
終了ページ 257
ISSN 0030-1558
言語 Japanese
著作権者 Copyright (c) 2010 岡山医学会
論文のバージョン publisher
DOI 10.4044/joma.122.253
NAID 130004903185
著者 島村 安則| 井上 円加| 小澤 正嗣| 金澤 智子| 斎藤 太一| 中原 龍一| 野田 知之| 西田 圭一郎| 尾﨑 敏文|
発行日 2011-08-01
出版物タイトル 岡山医学会雑誌
123巻
2号
資料タイプ 学術雑誌論文
著者 Miyake, Yoshiaki| Furumatsu, Takayuki| Kubota, Satoshi| Kawata, Kazumi| Ozaki, Toshifumi| Takigawa, Masaharu|
発行日 2011-06-03
出版物タイトル Biochemical and Biophysical Research Communications
409巻
2号
資料タイプ 学術雑誌論文
著者 Saiga, Kenta| Furumatsu, Takayuki| Yoshida, Aki| Masuda, Shin| Takihira, Shota| Abe, Nobuhiro| Ozaki, Toshifumi|
発行日 2010-11-12
出版物タイトル Biochemical and Biophysical Research Communications
402巻
2号
資料タイプ 学術雑誌論文
著者 Furumatsu, Takayuki| Hachioji, Motomi| Saiga, Kenta| Takata, Naoki| Yokoyama, Yusuke| Ozaki, Toshifumi|
発行日 2010-01-01
出版物タイトル Biochemical and Biophysical Research Communications
391巻
1号
資料タイプ 学術雑誌論文
著者 Furumatsu, Takayuki| Shukunami, Chisa| Amemiya-Kudo, Michiyo| Shimano, Hitoshi| Ozaki, Toshifumi|
発行日 2010-01
出版物タイトル The International Journal of Biochemistry & Cell Biology
42巻
1号
資料タイプ 学術雑誌論文
著者 Furumatsu, Takayuki| Ozaki, Toshifumi| Asahara, Hiroshi|
発行日 2009-05
出版物タイトル The International Journal of Biochemistry & Cell Biology
41巻
5号
資料タイプ 学術雑誌論文
著者 Tetsunaga, Tomonori| Furumatsu, Takayuki| Abe, Nobuhiro| Nishida, Keiichiro| Naruse, Keiji| Ozaki, Toshifumi|
発行日 2009-09-18
出版物タイトル Journal of Biomechanics
42巻
13号
資料タイプ 学術雑誌論文
著者 森本 裕樹| 尾﨑 敏文|
発行日 2011-12-01
出版物タイトル 岡山医学会雑誌
123巻
3号
資料タイプ 学術雑誌論文
著者 Furumatsu, Takayuki| Matsumoto, Emi| Kanazawa, Tomoko| Fujii, Masataka| Lu, Zhichao| Kajiki, Ryotaro| Ozaki, Toshifumi|
発行日 2013-05-31
出版物タイトル Journal of Biomechanics
46巻
9号
資料タイプ 学術雑誌論文
著者 Hasei, Joe| Sasaki, Tsuyoshi| Tazawa, Hiroshi| Osaki, Shuhei| Yamakawa, Yasuaki| Kunisada, Toshiyuki| Yoshida, Aki| Hashimoto, Yuuri| Onishi, Teppei| Uno, Futoshi| Kagawa, Shunsuke| Urata, Yasuo| Ozaki, Toshifumi| Fujiwara, Toshiyoshi|
発行日 2013-03
出版物タイトル Molecular Cancer Therapeutics
12巻
3号
資料タイプ 学術雑誌論文
JaLCDOI 10.18926/AMO/30721
フルテキストURL fulltext.pdf
著者 Inoue, Atsushi| Asaumi, Koji| Endo, Hirosuke| Fujiwara, Kazuo| Mitani, Shigeru| Ozaki, Toshifumi|
抄録 The present retrospective study assessed radiographs to determine socket wear in total hip arthroplasty (THA) with 22-mm zirconia or COP (Cobalt-Chrome alloy rich in Cobalt and Phosphorous) heads, and in cemented stems at more than 10 years after operation. Sockets of ultra high molecular weight polyethylene were used in each of two THA groups (13 hips each) in a clinical trial in our hospital between 1989 and 1990. Three observers carried out masked assessments of the radiographs. Upon fi nal examination, there was no remarkable loosening in the zirconia or COP group, and no case had required revision surgery as of 2005. There was a statistically signifi cant diff erence between the 2 groups in average annual linear wear, at 0.093 mm/year and 0.046 mm/year in the zirconia and COP groups, respectively. Volume wear and average annual volume wear were also signifi cantly greater in the zirconia group despite its superior mechanical strength and toughness in vitro. Our present fi ndings do not confi rm early expectations of lower wear in long-term results of 22-mm zirconia femoral heads used in THA.
キーワード total hip arthroplasty zirconia head COP head polyethylene wear
Amo Type Original Article
発行日 2006-12
出版物タイトル Acta Medica Okayama
60巻
6号
出版者 Okayama University Medical School
開始ページ 311
終了ページ 318
ISSN 0386-300X
NCID AA00508441
資料タイプ 学術雑誌論文
言語 English
論文のバージョン publisher
査読 有り
PubMed ID 17189974
Web of Science KeyUT 000243019000002