フルテキストURL | fulltext.pdf |
---|---|
著者 | Yamamoto, Norio| Sukegawa, Shintaro | Kitamura, Akira| Goto, Ryosuke| Noda, Tomoyuki| Nakano, Keisuke| Takabatake, Kiyofumi| Kawai, Hotaka| Nagatsuka, Hitoshi| Kawasaki, Keisuke| Furuki, Yoshihiko| Ozaki, Toshifumi| |
キーワード | osteoporosis deep learning hip radiograph ensemble model |
発行日 | 2020-11-10 |
出版物タイトル | Biomolecules |
巻 | 10巻 |
号 | 11号 |
出版者 | MDPI |
開始ページ | 1534 |
ISSN | 2218-273X |
資料タイプ | 学術雑誌論文 |
言語 | English |
OAI-PMH Set | 岡山大学 |
著作権者 | © 2020 by the authors. |
論文のバージョン | publisher |
PubMed ID | 33182778 |
DOI | 10.3390/biom10111534 |
Web of Science KeyUT | 000592980100001 |
関連URL | isVersionOf https://doi.org/10.3390/biom10111534 |
JaLCDOI | 10.18926/AMO/58274 |
---|---|
フルテキストURL | 74_2_151.pdf |
著者 | Yamamoto, Norio| Dan’ura, Tomoyuki| Noda, Tomoyuki| Ozaki, Toshifumi| |
抄録 | This is the second report of an atypical peri-implant femoral fracture occurring at the distal screw after intramedullary nail fixation of a pertrochanteric fracture. A 94-year-old Japanese female with a 5-year history of alendronate intake presented with prodromal pain in her right thigh after intramedullary nail fixation. Plain radiographs showed an incomplete noncomminuted transverse fracture at the distal screw, suggesting an atypical peri-implant femoral fracture. The pathogenesis of an atypical peri-implant femoral fracture could be a combined systemic bone metabolism disorder and repetitive overloading at the screw, similar to the pathogenesis of an atypical periprosthetic femoral fracture around stem implantation. |
キーワード | atypical femoral fracture insufficiency fracture bisphosphonate atypical peri-implant femoral fracture, atypical periprosthetic femoral fracture |
Amo Type | Case Report |
発行日 | 2020-04 |
出版物タイトル | Acta Medica Okayama |
巻 | 74巻 |
号 | 2号 |
出版者 | Okayama University Medical School |
開始ページ | 151 |
終了ページ | 157 |
ISSN | 0386-300X |
NCID | AA00508441 |
資料タイプ | 学術雑誌論文 |
言語 | English |
著作権者 | CopyrightⒸ 2020 by Okayama University Medical School |
論文のバージョン | publisher |
査読 | 有り |
PubMed ID | 32341590 |
Web of Science KeyUT | 000528278500009 |
NAID | 120006839453 |
フルテキストURL | fulltext.pdf |
---|---|
著者 | Saito, Taichi| Noda, Tomoyuki| Kondo, Hiroya| Demiya, Koji| Nezu, Satoshi| Yokoo, Suguru| Matsuhashi, Minami| Uehara, Takenori| Shimamura, Yasunori| Kodama, Masayuki| Ozaki, Toshifumi| |
抄録(別表記) | Septic arthritis in distal interphalangeal (DIP) joints sometimes occurs in association with mucous cysts or after the surgical treatment of mallet fingers. Recently, several studies have demonstrated... |
キーワード | Hand Induced membrane Masquelet technique Septic arthritis The small joint |
発行日 | 2020-02-29 |
出版物タイトル | Trauma Case Reports |
巻 | 25巻 |
開始ページ | 100268 |
ISSN | 23526440 |
資料タイプ | 学術雑誌論文 |
言語 | English |
OAI-PMH Set | 岡山大学 |
著作権者 | © 2019 The Authors. Published by Elsevier Ltd. |
論文のバージョン | publisher |
PubMed ID | 1890833 |
DOI | 10.1016/j.tcr.2019.100268 |
関連URL | isVersionOf https://doi.org/10.1016/j.tcr.2019.100268 |
フルテキストURL | AOTS20191023.pdf fig.pdf Table.pdf |
---|---|
著者 | Yamamoto, Norio| Noda, Tomoyuki| Saito, Taichi| Uehara, Takenori| Shimamura, Yasunori| Ozaki, Toshifumi| |
キーワード | Acetabular fracture External iliac artery External iliac vein Ilioinguinal approach Occlusion Thrombosis |
備考 | This is a post-peer-review, pre-copyedit version of an article published in Archives of Orthopaedic and Trauma Surgery. The final authenticated version is available online at: http://dx.doi.org/10.1007/s00402-019-03288-3.| |
発行日 | 2019-10-23 |
出版物タイトル | Archives of Orthopaedic and Trauma Surgery |
巻 | 140巻 |
号 | 4号 |
出版者 | Springer |
開始ページ | 481 |
終了ページ | 485 |
ISSN | 0936-8051 |
NCID | AA10738765 |
資料タイプ | 学術雑誌論文 |
言語 | English |
OAI-PMH Set | 岡山大学 |
論文のバージョン | author |
PubMed ID | 31642955 |
DOI | 10.1007/s00402-019-03288-3 |
Web of Science KeyUT | 000492001100001 |
関連URL | isVersionOf https://doi.org/10.1007/s00402-019-03288-3 |
著者 | Kinami, Yo| Noda, Tomoyuki| Ozaki, Toshifumi| |
---|---|
発行日 | 2013-05 |
出版物タイトル | Journal of Orthopaedic Science |
巻 | 18巻 |
号 | 3号 |
資料タイプ | 学術雑誌論文 |
著者 | 島村 安則| 井上 円加| 小澤 正嗣| 金澤 智子| 斎藤 太一| 中原 龍一| 野田 知之| 西田 圭一郎| 尾﨑 敏文| |
---|---|
発行日 | 2011-08-01 |
出版物タイトル | 岡山医学会雑誌 |
巻 | 123巻 |
号 | 2号 |
資料タイプ | 学術雑誌論文 |
タイトル(別表記) | Japanese guidelines for the treatment of hip fractures in the elderly |
---|---|
フルテキストURL | 122_253.pdf |
著者 | 野田 知之| 尾﨑 敏文| |
出版物タイトル | 岡山医学会雑誌 |
発行日 | 2010-12-01 |
巻 | 122巻 |
号 | 3号 |
開始ページ | 253 |
終了ページ | 257 |
ISSN | 0030-1558 |
言語 | Japanese |
著作権者 | Copyright (c) 2010 岡山医学会 |
論文のバージョン | publisher |
DOI | 10.4044/joma.122.253 |
NAID | 130004903185 |
JaLCDOI | 10.18926/AMO/32855 |
---|---|
フルテキストURL | fulltext.pdf |
著者 | Shimamura, Yasunori| Nishida, Keiichiro| Imatani, Junya| Noda, Tomoyuki| Hashizume, Hiroyuki| Ohtsuka, Aiji| Ozaki, Toshifumi| |
抄録 | <p>We biomechanically evaluated the bone fixation rigidity of an ONI plate (Group I) during fixation of experimentally created transcondylar humerus fractures in cadaveric elbows, which are the most frequently observed humeral fractures in the elderly, and compared it with the rigidity achieved by 3 conventional fixation methods:an LCP reconstruction plate 3.5 using a locking mechanism (Group II), a conventional reconstruction plate 3.5 (CRP) with a cannulated cancellous screw (Group III), and a CRP with 2 cannulated cancellous screws (CS) in a crisscross orientation (Group IV). In the axial loading test, the mean failure loads were:Group I, 98.9+/-32.6;Group II, 108.5+/-27.2;Group III, 50.0+/-7.5;and Group IV, 34.5+/-12.2 (N). Group I fixations failed at a significantly higher load than those of Groups III and IV (p0.05). In the extension loading test, the mean failure loads were:Group I, 34.0+/-12.4;Group II, 51.0+/-14.8;Group III, 19.3+/-6.0;and Group IV, 14.7+/-3.1 (N). Group IV fixations showed a significantly lower failure load than those of Group I (p0.05). The fixation rigidities against mechanical loading by the ONI plate and LCP plate were comparable. These results suggested that an ONI system might be superior to the CRP and CS method, and comparable to the LCP method in terms of fixation rigidity for distal humerus fractures.</p> |
キーワード | distal humerus fracture biomechanics internal fixation elderly |
Amo Type | Original Article |
発行日 | 2010-04 |
出版物タイトル | Acta Medica Okayama |
巻 | 64巻 |
号 | 2号 |
出版者 | Okayama University Medical School |
開始ページ | 115 |
終了ページ | 120 |
ISSN | 0386-300X |
NCID | AA00508441 |
資料タイプ | 学術雑誌論文 |
言語 | English |
論文のバージョン | publisher |
査読 | 有り |
PubMed ID | 20424666 |
Web of Science KeyUT | 000276996900005 |
JaLCDOI | 10.18926/AMO/32853 |
---|---|
フルテキストURL | fulltext.pdf |
著者 | Endo, Hirosuke| Noda, Tomoyuki| Mitani, Shigeru| Nakahara, Ryuichi| Tetsunaga, Tomonori| Kunisada, Toshiyuki| Ozaki, Toshifumi| |
抄録 | <p>Femoroacetabular impingement (FAI) is a condition characterized by the impingement of the femur and acetabulum. In Japan, this disorder has become recognized gradually. Here we report a rare case of surgically treated FAI, associated with an osseous protrusion on the acetabulum of a 30-year-old female. Plain computed tomography (CT) and reconstructive 3D-CT images clearly demonstrated an anterolateral bony protrusion. Hip arthroscopy showed no degeneration of the cartilage on either the femoral or acetabular side, but degeneration at the edge of labrum was observed in the region of the bony protrusion. The complete removal of the bony protrusion under hip arthroscopy was thus considered impracticable, and a small skin incision was therefore made anteriorly to approach the acetabulum. The Short-Form 36-Item Health Survey (SF-36) revealed improvement in all scores.</p> |
キーワード | femoroacetabular impingement bony protrusion Pincer type hip arthroscopy SF36 |
Amo Type | Case Report |
発行日 | 2010-04 |
出版物タイトル | Acta Medica Okayama |
巻 | 64巻 |
号 | 2号 |
出版者 | Okayama University Medical School |
開始ページ | 149 |
終了ページ | 154 |
ISSN | 0386-300X |
NCID | AA00508441 |
資料タイプ | 学術雑誌論文 |
言語 | English |
論文のバージョン | publisher |
査読 | 有り |
PubMed ID | 20424671 |
Web of Science KeyUT | 000276996900010 |
JaLCDOI | 10.18926/AMO/30972 |
---|---|
フルテキストURL | fulltext.pdf |
著者 | Endo, Hirosuke| Asaumi, Koji| Mitani, Shigeru| Noda, Tomoyuki| Minagawa, Hiroshi| Tetsunaga, Tomonori| Ozaki, Toshifumi| |
抄録 | <p>A minimally invasive plate osteosynthesis technique using a locking compression plate (LCP) has been used widely in trauma cases. Its advantages are that the MIPO technique does not interfere with the fracture site and thus provides improved biological healing, and that the LCP has excellent angular stability. Its use in bone lengthening, however, has not been established. In such cases, it is desirable to shorten the external skeletal fixation period as much as possible. Here, the MIPO technique using an LCP was applied to femoral distraction osteogenesis in an attempt to shorten the external skeletal fixation period. For femoral lengthening, the MIPO technique was performed in 2 stages. Orthofix external fixators (Orthofix, England) were used to insert screws from the anterolateral side rather than from the lateral side of the femur for bone lengthening. When sufficient callus formation was detected postoperatively at the site of bone lengthening, and the absence of infection was ensured, limb draping was performed, including a whole external fixator, and then the MIPO technique was applied with an LCP. In 3 cases (5 limbs), the average duration of external skeletal fixation was 134days, the average external-fixation index was 24days/cm, and the average consolidation index was 22days/cm. The MIPO technique using an LCP made it possible to shorten the external skeletal fixation-wearing period in femoral lengthening.</p> |
キーワード | femoral lengthening minimally invasive plate osteosynthesis locking compression plate external skeletal fixation external-fixation index |
Amo Type | Original Article |
発行日 | 2008-10 |
出版物タイトル | Acta Medica Okayama |
巻 | 62巻 |
号 | 5号 |
出版者 | Okayama University Medical School |
開始ページ | 333 |
終了ページ | 339 |
ISSN | 0386-300X |
NCID | AA00508441 |
資料タイプ | 学術雑誌論文 |
言語 | English |
論文のバージョン | publisher |
査読 | 有り |
PubMed ID | 18985094 |
Web of Science KeyUT | 000260391300008 |
著者 | 野田 知之| |
---|---|
発行日 | 2000-09-30 |
出版物タイトル | |
資料タイプ | 学位論文 |