ID | 14010 |
Eprint ID | 14010
|
FullText URL | |
Title Alternative | Measurement of cyclosporine concentration using radioimmunoassay with a specific monoclonal antibody : Preparing for the liver transplantation program in Okayama University Medical School
|
Author |
Sakagami, Kenichi
Matsuno, Tsuyoshi
Orita, Kunzo
Akiyama, Takao
|
Abstract | Cyclosporine, a new strong immunosuppressive agent, has dramatically improved the outcome of liver transplantation since its introduction to the clinical field in the 1980s.
Despite its efficacy, cyclosporine has a very narrow therapeutic window, wthich requires fine adjustment of the appropriate dose based on its concentration in the blood.
It will be necessary to obtain reliable data on a daily basis, when the liver transplantation program actually starts in the near future. To address this problem, we examined the utility of the radioimmunoassay kit using a specific monoclonal antibody (CYCLO-Trac WHOLE-BLOOD, Baxter, Japan), compared with the data derived from a commercial laboratory service (SRL, Japan). Each value of the cyclosporine concentration in the whole blood, measurely by CYCLO-Trac correlated with that of SRL(p<0.0001). CYCLO-Trac was suggested to be useful in obtaining a reliable data on a daily basis within our hospital.
|
Keywords | シクロスポリン
モノクロナル抗体
ラジオイムノアッセイ法
腎移植
肝移植
|
Published Date | 1993-02-27
|
Publication Title |
岡山医学会雑誌
|
Publication Title Alternative | Journal of Okayama Medical Association
|
Volume | volume105
|
Issue | issue1-2
|
Publisher | 岡山医学会
|
Publisher Alternative | Okayama Medical Association
|
Start Page | 227
|
End Page | 229
|
ISSN | 0030-1558
|
NCID | AN00032489
|
Content Type |
Journal Article
|
Official Url | https://www.jstage.jst.go.jp/article/joma1947/105/1-2/105_1-2_227/_article/-char/ja/
|
Related Url | http://www.okayama-u.ac.jp/user/oma/index.html
|
language |
Japanese
|
Copyright Holders | 岡山医学会
|
File Version | publisher
|
Refereed |
True
|