Author Nakagiri, Yoshitada| Azuma, Yoshiharu| Maruyama, Toshinori| Sibuya, Koichi| Goto, Sachiko| Sugita, Katsuhiko| Morioka, Yasuki| Kadohisa, Sigefumi| Inoue, Tatsuya| Hiraki, Yoshio|
Published Date 1998-08
Publication Title 環境制御
Volume volume20
Content Type Departmental Bulletin Paper
Author 東 義晴|
Published Date 1998-09-30
Publication Title
Content Type Thesis or Dissertation
JaLCDOI 10.18926/15252
Title Alternative Extended-cycle processによる乳房撮影用増感紙/フィルムシステムの画質改善
FullText URL 009_2_083_090.pdf
Author Goto, Sachiko| Maruyama, Toshinori| Azuma, Yoshiharu| Nakagiri, Yoshitada| Takeda, Yoshihiro| Sugita, Katsuhiko| Kimura, Fumie| Kadohisa, Shigefumi|
Abstract Extended-cycle process is the term used for a processor in which the processing time has been prolonged usually to approximate 210 seconds. It has been known that the extended-cycle process of some single-emulsion films as used for mammography may enhance film contrast and increase film speed. So the speed was increased in lower speed and higher resolution system than conventional systems by means of using the extended-cycle process in this paper. We investigated how much the resolution of the system was kept. A single screen-single emulsion combination, Konica M-100/CM-H was employed as a low speed and high resolution system. This film after exposure was processed in the different combinations of developing temperatures, 30, 32 and 34℃, and processing time of 210 seconds. On the other hand, Konica M-200/CM-H was employed as a high speed system. This film was processed in the standard-cycle processing (34℃, 90 seconds). Those systems were compared on contrast, speed, screen-film blur and noise by a characteristic curve, MTF (modulation transfer function) and WS (wiener spectrum). Furthermore, the RMI 165 phantom was used to evaluate visibility of mammographic details of these systems. As a result, in the extended-cycle process at the developing temperatures of 32 or 34°C and processing time of 210 seconds for M-100/CM-H, it was possible to increase the speed as much as the higher speed system, M-200/CM-H. Then the contrast, the MTF and the visibility were also improved as compared to the higher speed system. Furthermore patient dose could be reduced at the developing temperature of 34℃ and processing time of 210 seconds in M-100/CM-H.
Abstract Alternative 通常,extended-cycle processは処理時間が約210秒に延ばされた現像機のために使われる用語である。乳房撮影に使われるような片面乳剤フィルムにおけるextended-cycle processは,フィルムコントラストを増し,感度をあげることが良く知られている。そこで,本論文ではextended-cycle processにより低感度,高解像度システムの感度を上げ,どの程度解像度が維持されるかを調べた。片面増感紙/片面フィルムの組合わせであるKonica M-100/CM-Hを低感度,高解像度システムとして用いた。露光後のフィルムは現像温度30,32, 34度,処理時間210秒の異なる組合わせで現像処理した。一方,高感度システムとしてKonica M-200/CM-Hを用い,このフィルムは標準現像(34℃,90秒)された。感度,増感紙/フイルムのぼけ,雑音に関して,特性曲線,MTF(modulation transfer function), WS(wiener spectrum)によってこれらのシステムを比較した。さらにこれらのシステムにおける乳房写真の細部視覚評価のためにRM165ファントムを使用した。その結果,M-100/CM-Hに対するextended-cycle process現像温度32, 34℃,処理時間210秒のextended-cycle processにおいて,高感度システムM-200/CM-Hと同等の感度を上げることが可能であった。そのとき,コントラスト,MTF,視覚的検出能も高感度システムより向上した。さらに,現像温度34℃,処理時間210秒では,被曝線量の低減が可能であった。
Keywords image quality mammography single screen-single emulsion film system high-resolution screen extended-cycle process
Publication Title 岡山大学医療技術短期大学部紀要
Published Date 1999-02-26
Volume volume9
Issue issue2
Start Page 83
End Page 90
ISSN 0917-4494
language 英語
File Version publisher
NAID 120002307881
JaLCDOI 10.18926/11714
Title Alternative スクリーン/フィルム乳房撮影法における乳房線量測定システム
FullText URL 010_2_099_106.pdf
Author Goto, Sachiko| Azuma, Yoshiharu| Maruyama, Toshinori| Nakagiri, Yoshitada| Takeda, Yoshihiro| Sugita, Katsuhiko| Kadohisa, Shigefumi|
Abstract The average glandular dose to glandular tissue m mammography is generally assumed to be a function of beam quality (HVL), x-ray tube target material, tube voltage, breast thickness, breast composition and, to a lesser extent, x-ray tube voltage waveform. The average glandular dose is generally determined from published tables with knowledge of the above function. Tables for a high frequency x-ray generator are not yet published. In our study, the lookup tables for the average glandular dose were made at 28 kV (high frequency x-ray generator), employing a breast simulating tissue (0-100% adipose tissue, 0-100% glandular tissue) phantom for an Mo target - Mo filter source assembly. We tried to estimate breast composition from x-ray mammograms by digital image processing techniques, also using the simulating tissue phantom. Then the system that automatically calculates the average glandular dose from digitized clinical x-ray mammograms was built. It is considered that this system can contribute to objective evaluation of the average glandular dose.
Abstract Alternative 乳房X線撮影法において乳腺組織に対する平均放射線吸収線量,すなわち平均乳腺線量は放射線のリスクの最も有用な測定法であり,現在,乳房に対する線量の評価に用いられている指標である。一般に,平均乳腺線量は線質(HVL),X線管球ターゲット材料,管電圧,圧迫乳房厚さ,乳房構成および(ある程度)X線管電圧波形の関数であるとされている。平均乳腺線量は,上記の関数についての情報を備えた表が公表されており,一般にその表を使って決定されている。近年,インバータ式といわれる高周波X線発生装置が普及してきた。しかし,その装置用の表は,まだ公表されていない。我々の研究では,乳房組織をシュミレートするファントム(0~100%乳腺組織,0~100%脂肪組織)を使用して,28kVでMoターゲット―Moフィルタソースアセンブリーを備えた高周波X線発生装置のために,平均乳腺線量用のルックアップテーブルを作成した。同様に,乳房組織をシュミレートするファントムを使用して,乳房X線写真から,ディジタル・イメージプロセシング技術によって,乳房構成の評価を試みた。そして,ディジタイズされた臨床乳房X線写真から,平均乳腺線量を自動的に計算するシステムを構築した。サンプル数が少ないため断定はできないが,日本女性は,基準構成(50%の脂肪および50%の乳腺組織)と比較すると,脂肪が少ない傾向を分析結果は示唆していた。また,平均乳腺吸収線量の限度は,明確に規定されていないが,American College of Radiology(ACR)は4 mGyなどを推奨している。また日本では,3 mGyが推奨されているが,我々の撮影システムはこれらを十分満足していた。このように本システムは,平均乳腺線量の客観的な評価に寄与するとともに,DR(digital radiography)などに応用すると,すなわちルックアップテーブルをDRのコンピュータに保存しておけば,撮影後すぐに乳房構成および平均乳腺線量を算出できる可能性をもつ。
Keywords Screen/Film Mammography (スクリーン/フィルム乳房撮影法) Breast composition (乳房構成) Average glandular dose (平均乳腺線量) Entrance skin exposure (皮膚入射線量) Breast-equivalent material phantom (乳房組織等価ファントム)
Publication Title 岡山大学医学部保健学科紀要
Published Date 2000-03-24
Volume volume10
Issue issue2
Start Page 99
End Page 106
ISSN 1345-0948
language 英語
File Version publisher
NAID 120002313736
JaLCDOI 10.18926/11721
Title Alternative The influence of air attenuation in characteristic curve for mammographic screen-film system
FullText URL 010_2_091_098.pdf
Author Maruyama, Toshinori| Goto, Sachiko| Azuma, Yoshiharu| Nakagiri, Yoshitada| Shibuya, Koichi| Sugita, Katsuhiko|
Abstract マンモグラフィ専用装置を使用して,距離法で低エネルギー領域のX線におけるマンモグラフィ用増感紙/フィルムシステムの特性曲線を得るためには,空気滅弱の影響を考慮する必要がある。その影響について,実効エネルギーから空気減弱分を補正,照射線量測定による補正,Bednarek法を応用した新距離法の3種類の方法を使って検討した。さらに,一般撮影装置でも,マンモ用システムに対して距離法で特性曲線を作成し,エネルギ ーの変化による影響についても検討した。その結果,3方法の特性曲線およびグラディエント曲線は,新距離法が高濃度域でわずかにずれるもののほぼ一致した。新距離法に対する平均階調度,最大階調度の最大誤差は,2.7%,0.2%であり,一般撮影用装置の距離法と3方法との間では,一般撮影用装置の距離法に対して最大誤差は2.7%,1.5%であった。以上のことから,エネルギーの変化による特性曲線への影響はほとんどなく,低エネルギー領域での特性曲線は空気特配の補正を行うことのみで得られると考えられる。
Abstract Alternative It is necessary to take air attenuation into account when we use inverse square sensitometry to obtain characteristic curve for the mammographic screen-film system at low x-ray energies as used with the dedicated unit. Three kinds of the inverse square sensitometry approach of correcting by air attenuation obtained from effective energy, of correcting by exposure dosimetry and of using modified the technique of Bednarek were employed to investigated the influence of x-ray energy in the characteristic curves for the mammographic screen-film system. In addition, the inverse square sensitometry with the general radiographic unit was employed and the influence of x-ray high energy in the characteristic curves was also investigated for the same screeri-film system. Though characteristic curves and gradient curves of the new inverse square sensitometry were a little lower than the others in high-density region, the curves with three kinds of methods almost coincided. Maximum relative errors of average gradient and maximum gradient for modified the technique of Bednarek were found to be 2.7% and 0.2% among the others respectively. Moreover, maximum relative errors of gradient and maximum gradient for the inverse square sensitometry with the general radiographic unit were 2.7% and 1.5% among three kinds of methods with the dedicated unit respectively. It was considered that the characteristic curves for the mammographic screen-film system were little influenced by x-ray energy and could be obtained only by correcting air attenuation from above results.
Keywords マンモグラフィ (mammography) 低エネルギー領域 (low x-ray energy) 特性曲線 (characteristic curve) 距離法 (inverse square sensitometry) 空気減弱 (air attenuation)
Publication Title 岡山大学医学部保健学科紀要
Published Date 2000-03-24
Volume volume10
Issue issue2
Start Page 91
End Page 98
ISSN 1345-0948
language 日本語
File Version publisher
NAID 120002313929
JaLCDOI 10.18926/11690
Title Alternative A study of x-rays protection in a hip-joint radiography examination
FullText URL 011_2_059_064.pdf
Author Nakagiri, Yoshitada| Maruyama, Toshinori| Goto, Sachiko| Azuma, Yoshiharu| Shibuya, Koichi| Tamura, Eri| Tanimoto, Eriko| Torii, Fumiko| Takeda, Yoshihiro| Sugita, Katsuhiko|
Abstract 幼小児を含めた若年者の股関節X線撮影検査においては鉛板などで生殖腺を防護して行うのが通常である。男性の場合は生殖腺は体外に露出しているので,それを鉛板で包むようにすればある程度目的は達成される。しかし,女性の場合,生殖腺は骨盤腔内に存在するため,卵巣及び子宮を防護でき診断目的領域にかからないように鉛板を成形し,腹壁上に置いて撮影する。X斬写真上ではグリッドで散乱線を除去しているため,鉛板の陰影がくっきりと撮影され,生殖腺は完全に防護されているように見える。しかし,体内では散乱線によるかなりの被曝があるものと考えられる。そこで今回,鉛板下の散乱線量を鉛板幅及び電圧を変化させ,ファントム内各深さの散乱線量を測定した。その結果,鉛板下の散乱線量が相当量認められ,その量は深さ3~4cmでピークを形成した。鉛板幅による変化は幅が狭いほど線量は大きくなり,電圧による変化は60kVと80kVを比べると80kVの方が多くなった。これを鉛板なしの場合と比較すると,ファントム内意さが増すにしたがい増大した。したがって,臨床において鉛板がずれて再撮影をすることのないよう細心の注意が必要であると考えられた。
Abstract Alternative Usually in a hip-joint radiographic examination for the youth including children, the gonads should be well protected with an appropriate lead shield etc. Since the male gonads are in the outside of the body, if covered with a lead shield, the shield can protect them. However, in the case of the female, since the gonads of exist in a pelvic cavity, the lead shield is cut to a specific pattern so that it can protect the ovaries and the womb, and it is set on the abdomen during the radiographic exposure. Since the scattered radiation on an X-ray film can be removed with the grid, the image of a lead shield is obtained clearly, and the gonads seem to be protected completely. The shield can not protect the gonads of the female from the scattered radiation, though it protects them almost completely from the primary X-rays beam. Therefore, the gonads have radioactive contamination from scattered radiation. Then, in order to estimate the amount of scattered radiation under the lead shield, the dose under the shield was measured by using a phantom in this research, changing lead shield width, the tube-voltage, and the monitoring depth of a phantom. As a results, the dose under the lead shield was observed considerably and showed the peak at the depth of 3 or 4cm. Therefore, it was thought that a careful caution was required for obviating lead shield in clinical.
Keywords 股関節X線撮影 (Radiography Examination of Hip-joint) 医療被爆 (Patient Dose) X線測定 (Dosimetry) 生殖腺防護 (X-rays Protection of the Gonads)
Publication Title 岡山大学医学部保健学科紀要
Published Date 2001-03-24
Volume volume11
Issue issue2
Start Page 59
End Page 64
ISSN 1345-0948
language 日本語
File Version publisher
NAID 120002313720
Author Sumimoto, Tetsuhiro| Maruyama, Toshinori| Azuma, Yoshiharu| Goto, Sachiko| Mondou, Munehiro| Furukawa, Noboru| Okada, Saburo|
Published Date 2002-12
Publication Title Industrial Technology
Volume volume1
Content Type Journal Article
JaLCDOI 10.18926/15204
Title Alternative Characteristic of GAFCHROMIC XR TYPE T dosimetry film
FullText URL 014_1_023_029.pdf
Author Kubotsu, Mariko| Nakagiri, Yoshitada| Ujifuku, Ayako| Taniguchi, Yukiko| Hachiya, Miho| Azuma, Yoshiharu| Goto, Sachiko| Maruyama, Toshinori| Aoyama, Hideki| Tahara, Seiji| Inamura, Keiji| Watanabe, Toshimitsu| Sugita, Katsuhiko|
Abstract 医療の高度化に伴い,近年では長時間のⅩ線透視を行うInterventional Radiology(IVR)手技が頻繁に行われ,副作用としての難治性放射線皮膚障害例の報告が増加している。確定的影響である放射線皮膚障害はしきい値を超えると発症し,線量に依存して障害の程度が重篤となるため,患者被曝線量の測定が重要である。しかし,IVRでは照射部位が多彩で,焦点-皮膚間距離が不安定なため,その測定方法は確立されていない。本研究では,近年IVR等低エネルギー線量測定用フイルムとして開発されたCAFCHROMIC XR TYPE T について性能評価を行い,患者皮膚入射面の被曝線量測定への応用の可能性について検討した。その結果,線量特性,線質特性,ネット値の安定性に良好な特性を示し,臨床に使用可能であったので報告する。
Abstract Alternative In recent years, interventional radiology (IVR) using which uses prolomged fluoroscopy has been performed frequently in clinical radiology. Also, reports of radiation skin injuries whose symptoms occur after IVR has been also increasing. These symptoms will become worse if the radiation induced skin injuries are caused by doses which are above the designated threshold, and the grade of injuries are dependent on dose. Therefore, it is important that patient skin dose is measured correctly. But when perfoming IVR, irradiation is complex pricedure, and there is a measurement error with an unfixed source-to-skin distance. So. in this paper, characteristics of GAFCHROMIC XR TYPE T (which are film for low energy X-rays) are performed. Then, they are decided whether the application to the skin surface incidence dose measurement whoud be posible. From these results usefull data can be obtainned; for exanmpe film characteristics, energy factors and stability of sensivility.
Keywords 患者被爆線量 (Patient Exposure dose) GAFCHROMIC XR TYPE T Radiochromic film Interventional Radiology (IVR) 測定精度 (Radiation dosimetry)
Publication Title 岡山大学医学部保健学科紀要
Published Date 2003-12-25
Volume volume14
Issue issue1
Start Page 23
End Page 29
ISSN 1345-0948
language 日本語
File Version publisher
NAID 120002307331
Author Sumimoto, Tetsuhiro| Maruyama, Toshinori| Azuma, Yoshiharu| Goto, Sachiko| Mondou, Munehiro| Furukawa, Noboru| Okada, Saburo|
Published Date 2003-5
Publication Title Instrumentation and Measurement Technology Conference
Volume volume2
Content Type Journal Article