Environmental Research & Control
Published by Environmental Management Center, Okayama University

<Formerly known as>
岡山大学環境管理センター報 (4号-11号) 岡山大学環境管理施設報 (1号-3号)

<Availability>
Some items are not available because of decision by its author or publisher.

誘電率計測法による地盤の汚染度及び有効間隙率の測定方法に関する基礎的研究

Kim, Man-il
Abstract
For evaluating subsurface contamination, sampling method (boring) is commonly used, but this method cannot monitor the change of in-situ contamination and concentration with respect to time. The purpose of this study is to develop a measuring system for subsurface contamination in which a so-called FDR (Frequency Domain Refiectometry) and FDR-V (with Vector network analyzer) system was employed to measure the salinity and oil contaminant. This FDR and FDR-V method is a coaxial probe method, which allows the measurement of the dielectric. The experimental study indicates the possibility in measuring both the contaminant concentration and volumetric moisture content. In addition, the method for obtaining the effective porosity using this equipment was shown. Concretely, the sensor was inserted in the ground, and the liquid in which the dielectric constant differed on the water in the circumference was injected, and the method for obtaining the effective porosity from the change of the dielectric constant was proposed.
Keywords
Dielectric constant
Contamination
Frequency Domain Refiectometry
In-situ
Effective porosity
Note
論文
ISSN
0917-1533
NCID
AN1024789X