このエントリーをはてなブックマークに追加
ID 42576
FullText URL
Thumnail 69_1533.pdf 7.63 MB
Title Alternative
I. A Comparative Study of Precipitin Reaction (Ring test and Mixture test) with the Use of U-tube
Author
Nakai, Kozo
Abstract
By devising a precipitin reaction with the use of U-tube and using Ogata's antigenantibody dilution test, ring test and mixture test have been compared, the results of which are as follows: 1) In the precipitin reaction with the use of a U-tube, antibody titer centering around the "binding zone" has been found two times more dilute than that observed in the mixture test. and the titer has almost coincided with antibody titer of the ring test. 2) This U-tube test suits convenience to manipulate tnan the ring test, and moreover, it affords relatively better observation results. 3) The U-tubes are washed out easily than capillary tubes. 4) The precipitate obtained by the precipitin reaction has presented mobility by electrophoresis equivalent to γ-globulin of original serum.
Published Date
1957-06-30
Publication Title
岡山医学会雑誌
Publication Title Alternative
Journal of Okayama Medical Association
Volume
volume69
Issue
issue6
Publisher
岡山医学会
Publisher Alternative
Okayama Medical Association
Start Page
1533
End Page
1538
ISSN
0030-1558
NCID
AN00032489
Content Type
Journal Article
Official Url
https://www.jstage.jst.go.jp/article/joma1947/69/6/69_6_1533/_article/-char/ja/
Related Url
http://www.okayama-u.ac.jp/user/oma/
language
日本語
Copyright Holders
Copyright© 岡山医学会
File Version
publisher
Refereed
True
Eprints Journal Name
joma